Variability in computer-aided detection effect on adenoma detection rate in randomized controlled trials: A meta-regression analysis
Digestive and Liver Disease · 2025-06 · 57 (6) · 1141-1148
DOI: 10.1016/j.dld.2025.01.192 ↗Kurz gefasst
Metaanalyse in der Zeitschrift Digestive and Liver Disease, 2025-06. Verfasst von Marco Spadaccini und 16 weiteren Autor:innen. Beteiligte Einrichtung: Humanitas University, Department of Biomedical Sciences, Pieve Emanuele, Italy; Humanitas Clinical and Research Center -IRCCS-, Endoscopy Unit, Rozza…. Hauptthemen laut MEDLINE: Adenoma, Colonoscopy, Colorectal Neoplasms, Diagnosis, Computer-Assisted. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 37 Literaturangaben. Gefördert von: European Commission.
Abstract (Originalsprache)
BACKGROUND: Computer-aided detection (CADe) systems may increase adenoma detection rate (ADR) during colonoscopy. However, the variable results of CADe effects in different RCTs warrant investigation into factors influencing these results. AIMS: Investigate the different variables possibly affecting the impact of CADe-assisted colonoscopy and its effect on ADR. METHODS: We searched MEDLINE, EMBASE, and Scopus databases until July 2023 for RCTs reporting performance of CADe systems in the detection of colorectal neoplasia. The main outcome was pooled ADR. A random-effects meta-analysis was performed to obtain the pooled risk ratios (RR) with 95 % confidence intervals (CI)). To explore sources of heterogeneity, we conducted a meta-regression analysis using both univariable and multivariable mixed-effects models. Potential explanatory variables included factors influencing adenoma prevalence, such as patient gender, age, and colonoscopy indication. We also included both key (ADR), and minor (Withdrawal time) performance measures considered as quality indicators for colonoscopy. RESULTS: Twenty-three randomized controlled trials (RCTs) on 19,077 patients were include. ADR was higher in the CADe group (46 % [95 % CI 39-52]) than in the standard colonoscopy group (38 % [95 % CI 31-46]) with a risk ratio of 1.22 [95 % CI 1.14-1.29]); and a substantial level of heterogeneity (I2 = 67.69 %). In the univariable meta-regression analysis, patient age, ADR in control arms, and withdrawal time were the strongest predictors of CADe effect on ADR (P < .001). In multivariable meta-regression, ADR in control arms, and withdrawal time were simultaneous significant predictors of the proportion of the CADe effect on ADR. CONCLUSION: The substantial level of heterogeneity found appeared to be associated with variability in colonoscopy quality performances across the studies, namely ADR in control arm, and withdrawal time.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Humanitas University, Department of Biomedical Sciences, Pieve Emanuele, Italy; Humanitas Clinical and Research Center -IRCCS-, Endoscopy Unit, Rozzano, Italy. Electronic address: marco.spadaccini@humanitas.it.
- Humanitas University, Department of Biomedical Sciences, Pieve Emanuele, Italy; Humanitas Clinical and Research Center -IRCCS-, Endoscopy Unit, Rozzano, Italy.
- University of Oslo, Clinical Effectiveness Research Group, Oslo, Norway; Showa University Northern Yokohama Hospital, Digestive Disease Center, Yokohama, Japan.
- Humanitas Clinical and Research Center -IRCCS-, Endoscopy Unit, Rozzano, Italy.
- University of Oslo, Clinical Effectiveness Research Group, Oslo, Norway; University of Salento, Gastroenterology Unit, Department of Experimental Medicine, Lecce, Italy.
- Kansas City VA Medical Center, Gastroenterology and Hepatology, Kansas City, United States.
Förderung
- European Commission
Zitieren
APA
Spadaccini, M., Hassan, C., Mori, Y., Massimi, D., Correale, L., Facciorusso, A., Patel, H. K., Rizkala, T., Khalaf, K., Ramai, D., Rondonotti, E., Maselli, R., Rex, D. K., Bhandari, P., Sharma, P., Repici, A., & CADe Study group (2025). Variability in computer-aided detection effect on adenoma detection rate in randomized controlled trials: A meta-regression analysis. Digestive and Liver Disease, 57(6), 1141-1148. https://doi.org/10.1016/j.dld.2025.01.192
Vancouver
Spadaccini M, Hassan C, Mori Y, Massimi D, Correale L, Facciorusso A, et al. Variability in computer-aided detection effect on adenoma detection rate in randomized controlled trials: A meta-regression analysis. Digestive and Liver Disease. 2025;57(6):1141-1148. doi:10.1016/j.dld.2025.01.192
BibTeX
@article{Spadaccini2025,
author = {Spadaccini, Marco and Hassan, Cesare and Mori, Yuichi and Massimi, Davide and Correale, Loredana and Facciorusso, Antonio and Patel, Harsh K and Rizkala, Tommy and Khalaf, Kareem and Ramai, Daryl and Rondonotti, Emanuele and Maselli, Roberta and Rex, Douglas K and Bhandari, Pradeep and Sharma, Prateek and Repici, Alessandro and CADe Study group, CADe Study group},
title = {Variability in computer-aided detection effect on adenoma detection rate in randomized controlled trials: A meta-regression analysis},
journal = {Digestive and Liver Disease},
year = {2025},
volume = {57},
number = {6},
pages = {1141--1148},
doi = {10.1016/j.dld.2025.01.192}
}
EUVIMED