Aims
Correct reprocessing of endoscopes is essential to prevent nosocomial infections and to ensure patient safety, and many outbreaks have been described in different studies in relation to poor reprocessing of endoscopes 1,2 . In this context, different reprocessing methods have been implemented, including high-level disinfection and point-of-use sterilisation. Microbiological controls are used to identify and detect failures in the reprocessing of endoscopes. The aim of this study is to evaluate the effectiveness of point-of-use sterilisation on the quality improvement of endoscope reprocessing. Preliminary results are presented here.
Methods
Comparative study analysing all samples taken for microbiological control of duodenoscopes and linear echoendoscopes used in two different periods; first half of 2022 where high-level disinfection was performed (period 1, P1) and first half of 2023 where point-of-use sterilisation was performed (period 2, P2), both with peracetic acid. Weekly, and according to the Preventive Medicine Service protocol, samples were collected from the channels and forceps of duodenoscopes and linear echoendoscopes once 12 hours had passed since the last reprocessing and drying of them. A descriptive analysis of the following variables was performed: type of endoscope, date of collection, microbiological culture result and type of microorganism. The data obtained have been managed using the EXCEL spreadsheet and the statistical analyses have been carried out using SPSS. [ 1 ] [ 2 ]
Results
A total of 169 samples were analysed in P1 and 238 samples in P2; duodenoscopes (N=130 in P1 and N=150 in P2) and echoendoscopes (N=38 in P1, N=88 in P2). Positivity in P1 was 24.3% (95% CI 18-31) while in P2 it was 32.8% (95% CI 31-42). There was significant difference in the positive/negative results of the samples tested, with OR 0.56 (95% CI 0.36-0.86, p=0.009) The results also revealed that positivity for high-risk microorganisms in P1 was 22% (95% CI 12-37) compared to 13.8% (95% CI 8-22) in P2. There was a higher probability of positivity for high-risk microorganisms in P1 with OR 1.76 (95% CI 0.67-4.58, p=0.25)
Conclusions
Although the international demand is for sterilisation of endoscopes that pass through mucosa, enter a sterile cavity or come into contact with blood, the preliminary results of our study have shown that point-of-use sterilisation is not relevant for improving the quality of endoscope reprocessing compared to high-level disinfection. That may be because the sterility resulting from point-of-use sterilisation disappears when the endoscope is transferred from the reprocessing area to the storage one and it is handled by the Endoscopy Unit staff. Continuous education and training of nursing staff and maintaining strict vigilance and control are necessary to ensure the highest safety for our patients. Publication History Article published online: 15 April 2024 © 2024. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
Zitieren
APA
Zamora, Y. C. T., Betancor, C. C., Vega, G. A., & Paez, A. M. B. (2024). Relevance of point-of-use sterilisation to improve the quality of endoscope reprocessing. Endoscopy, 56(S 02 S 02), S10. https://doi.org/10.1055/s-0044-1782705
Vancouver
Zamora YCT, Betancor CC, Vega GA, Paez AMB. Relevance of point-of-use sterilisation to improve the quality of endoscope reprocessing. Endoscopy. 2024;56(S 02 S 02):S10. doi:10.1055/s-0044-1782705
BibTeX
@article{Zamora2024,
author = {Zamora, Y. C. Torres and Betancor, C. Cárdenes and Vega, G. Aleman and Paez, A. M. Borja},
title = {Relevance of point-of-use sterilisation to improve the quality of endoscope reprocessing},
journal = {Endoscopy},
year = {2024},
volume = {56},
number = {S 02 S 02},
pages = {S10},
doi = {10.1055/s-0044-1782705}
}
EUVIMED