Mapping of Thoracodorsal Artery Perforators: Accuracy of Thermography and Handheld Doppler
Journal of Reconstructive Microsurgery · 01.09.2024 · 40 (07) · 551-558
DOI: 10.1055/s-0044-1779733 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Reconstructive Microsurgery, erschienen am 01.09.2024. Verfasst von Claudius Illg und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Hand-, Plastic, Reconstructive and Burn Surgery, BG Unfallklinik Tuebingen, Eberhard Karls University Tuebingen, Tuebingen, Germany. Hauptthemen laut MEDLINE: Thermography, Perforator Flap. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 45 Literaturangaben.
Abstract (Originalsprache)
Background
The versatile musculocutaneous latissimus dorsi flap and the thoracodorsal artery (TDA) perforator flap have developed into indispensable approaches in reconstructive surgery. While the anatomy of the TDA is consistent, the skin perforators vary in location and course. Dynamic infrared thermography (DIRT) recently gained popularity for perforator identification; however, its use and accuracy in thoracodorsal artery perforator (TDAP) mapping is yet to be determined.
Methods
TDAPs were visualized in 50 cases by DIRT. Based on the thermographic hotspots, the corresponding perforators were then identified by color duplex ultrasound (CDU) and handheld Doppler in a blinded fashion by two separate examiners.
Results
The midpoint of all perforator fascia passages was localized 99.7 mm caudal and 13.5 mm medial of the posterior axillary fold. The positive predictive value of perforator identification by dynamic infrared thermography was 86.5% and the correlating perforator fascia passage was 9.9 ± 5.8 mm from the hotspot midpoint, with a maximum of 29 mm. The positive predictive value of perforator identification by handheld Doppler was 95% and the signal was 7.2 ± 5.1 mm from the perforator fascia passage.
Conclusion
DIRT precisely localizes TDAPs. The fusion with CDU combines both modalities' advantages. The combination with handheld Doppler is a fast way of perforator imaging, decreasing the handheld Dopplers' high false positive rate.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Hand-, Plastic, Reconstructive and Burn Surgery, BG Unfallklinik Tuebingen, Eberhard Karls University Tuebingen, Tuebingen, Germany.
- Department of Pediatric Surgery, Klinik St. Hedwig, University Medical Center Regensburg, Regensburg, Germany.
ORCID-Profile: Claudius Illg, Markus Denzinger
Zitieren
APA
Illg, C., Heinzel, J. C., Denzinger, M., Schäfer, R. C., Daigeler, A., & Krauss, S. (2024). Mapping of Thoracodorsal Artery Perforators: Accuracy of Thermography and Handheld Doppler. Journal of Reconstructive Microsurgery, 40(07), 551-558. https://doi.org/10.1055/s-0044-1779733
Vancouver
Illg C, Heinzel JC, Denzinger M, Schäfer RC, Daigeler A, Krauss S. Mapping of Thoracodorsal Artery Perforators: Accuracy of Thermography and Handheld Doppler. Journal of Reconstructive Microsurgery. 2024;40(07):551-558. doi:10.1055/s-0044-1779733
BibTeX
@article{Illg2024,
author = {Illg, Claudius and Heinzel, Johannes C and Denzinger, Markus and Schäfer, Ruth C and Daigeler, Adrien and Krauss, Sabrina},
title = {Mapping of Thoracodorsal Artery Perforators: Accuracy of Thermography and Handheld Doppler},
journal = {Journal of Reconstructive Microsurgery},
year = {2024},
volume = {40},
number = {07},
pages = {551--558},
doi = {10.1055/s-0044-1779733}
}
EUVIMED