Thoracodorsal Artery Perforator Diameter and Flow Velocity Correlate with Muscle Thickness
Journal of Reconstructive Microsurgery · 01.01.2026 · 42 (01) · 030-037
DOI: 10.1055/a-2540-1100 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Reconstructive Microsurgery, erschienen am 01.01.2026. Verfasst von Claudius Illg und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Hand, Plastic, Reconstructive and Burn Surgery, BG Unfallklinik Tuebingen, Eberhard Karls University Tuebingen, Tuebingen, Germany. Hauptthemen laut MEDLINE: Perforator Flap, Superficial Back Muscles, Plastic Surgery Procedures. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 24 Literaturangaben.
Abstract (Originalsprache)
The thoracodorsal artery perforator (TDAP) flap is a versatile pedicled and free flap with low donor site morbidity and a relatively thin skin paddle. Physical patient characteristics may influence interindividual differences in perforator characteristics and, therefore, help to estimate the safety of the TDAP flap. Dynamic infrared thermography and color duplex ultrasound were applied to assess the TDAP diameter, peak systolic velocity (PSV), end-diastolic velocity, resistance index, and thickness of the latissimus dorsi muscle and the subcutaneous tissue bilaterally in 25 subjects. The effect of handedness on the symmetry of perforator characteristics was investigated. Perforator properties were not significantly altered by sex or body mass index. The mean latissimus dorsi muscle thickness correlated positively with both the perforator diameter (Pearson's r = 0.25, p = 0.0048, n = 124) and the PSV (r = 0.29, p = 0.0012, n = 124). In contrast, a negative correlation was observed between subcutaneous tissue thickness and PSV (r = −0.31, p = 0.0003, n = 124). A comparison of the perforator diameter and the PSV in the dominant and nondominant sides showed no statistically significant difference. The findings of the study indicate that perfusion of the thoracodorsal artery flap is enhanced by the presence of a thicker latissimus dorsi muscle, a thinner subcutaneous tissue, and a reduced quantity of TDAPs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Hand, Plastic, Reconstructive and Burn Surgery, BG Unfallklinik Tuebingen, Eberhard Karls University Tuebingen, Tuebingen, Germany.
ORCID-Profile: Claudius Illg
Zitieren
APA
Illg, C., Rachunek-Medved, K., Lauer, H., Thiel, J. T., Daigeler, A., & Krauss, S. (2026). Thoracodorsal Artery Perforator Diameter and Flow Velocity Correlate with Muscle Thickness. Journal of Reconstructive Microsurgery, 42(01), 030-037. https://doi.org/10.1055/a-2540-1100
Vancouver
Illg C, Rachunek-Medved K, Lauer H, Thiel JT, Daigeler A, Krauss S. Thoracodorsal Artery Perforator Diameter and Flow Velocity Correlate with Muscle Thickness. Journal of Reconstructive Microsurgery. 2026;42(01):030-037. doi:10.1055/a-2540-1100
BibTeX
@article{Illg2026,
author = {Illg, Claudius and Rachunek-Medved, Katarzyna and Lauer, Henrik and Thiel, Johannes Tobias and Daigeler, Adrien and Krauss, Sabrina},
title = {Thoracodorsal Artery Perforator Diameter and Flow Velocity Correlate with Muscle Thickness},
journal = {Journal of Reconstructive Microsurgery},
year = {2026},
volume = {42},
number = {01},
pages = {030--037},
doi = {10.1055/a-2540-1100}
}
EUVIMED