EUVIMEDEUVIMED entdecken
Crossref

Yield of single pass with Franseen needle compared to multiple passes with conventional FNA needles

P. N. Desai, K. Mayank, P. Chintan, P. Ritesh

Endoscopy · 01.04.2023 · 55 (S 02 S 02) · S263

DOI: 10.1055/s-0043-1765720 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.04.2023. Verfasst von P. N. Desai und 3 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Single pass FNA, FNB and/ or ancillary studies with Franseen needle without ROSE or MOSE compared with conventional FNA and/ or FNB with multiple passes using other needles.

Methods

Retrospectively analysis of data of EUS FNA / FNB of 5 years. Before 2019 FNA done with 22 or 25 G FNA needles with 3-5 passes slow pull technique. FNB done using 22 G Procore (Group A). After 2019 only Franseen needles used. Single needle and single pass without stylet or slow pull for FNA, FNB and/ or ancillary studies (Group B).

Results

Total 440. 277 male, 163 female. Sites: mediastinal LN (72), abdominal LN (116), liver (11), esophagus (6), gastric (2) rectal wall (3), periampullary (36), gall bladder (17). Diagnosis- malignancy 279, benign 139, nondiagnostic 22. Franseen in 270 (group B). Tissue adequacy 93.4% FNA and 91.6% FNB. Of 440 FNA, diagnosis not achieved 41 (27 inadequate, 1 false diagnosis). In 16 FNB helped. Of 276 FNB diagnosis 249. Diagnosis not reached in 25 FNB. 19 (4.3%) tissue inadequate. 12 FNA was positive. In 1 IHC got diagnosis. 2 mucosal biopsies. IHC 42 cases. 12 diagnosis not achieved by any modality. Duodenal and ampullary biopsy in 3. Rest final diagnosis in folllowup. No difference in tissue & diagnostic accuracy in Group A & B. Diagnostic accuracy better in FNA in B compared to A for malignancy (p=0.012).

Conclusions

Single pass each for FNA, FNB and/ or ancillary studies with Franseen comparable to multiple passes with conventional needle. Malignant lesions, single pass FNA with Franseen better diagnostic accuracy than conventional FNA with multiple passes. Publication History Article published online: 14 April 2023 © 2023. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

Zitieren

APA

Desai, P. N., Mayank, K., Chintan, P., & Ritesh, P. (2023). Yield of single pass with Franseen needle compared to multiple passes with conventional FNA needles. Endoscopy, 55(S 02 S 02), S263. https://doi.org/10.1055/s-0043-1765720

Vancouver

Desai PN, Mayank K, Chintan P, Ritesh P. Yield of single pass with Franseen needle compared to multiple passes with conventional FNA needles. Endoscopy. 2023;55(S 02 S 02):S263. doi:10.1055/s-0043-1765720

BibTeX
@article{Desai2023,
  author = {Desai, P. N. and Mayank, K. and Chintan, P. and Ritesh, P.},
  title = {Yield of single pass with Franseen needle compared to multiple passes with conventional FNA needles},
  journal = {Endoscopy},
  year = {2023},
  volume = {55},
  number = {S 02 S 02},
  pages = {S263},
  doi = {10.1055/s-0043-1765720}
}