Klinische Studie in der Zeitschrift Klinische Monatsblätter für Augenheilkunde, online erschienen am 04.11.2026. Verfasst von Thomas Kohnen und 4 weiteren Autor:innen. Beteiligte Einrichtung: Goethe University Frankfurt, Department of Opththalmology, Germany, Frankfurt. Die Arbeit nennt 35 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To evaluate the visual performance after bilateral implantation of a diffractive partial range of focus intraocular lens (RoF IOL) with a smooth microphase technology for less light scattering.

Design

Prospective case series.

Methods

Twenty patients (40 eyes) received bilateral implantation of a partial RoF IOL (AT LARA 829MP, Carl Zeiss Meditec, Jena, Germany) pre-enrolment. Exclusion criteria were previous ocular surgeries other than cataract surgery and refractive lens exchange, postoperative complications, ocular pathologies, or corneal abnormalities. Three months’ postoperative examination included manifest refraction, monocular and binocular uncorrected (UDVA), and distance-corrected visual acuity (DCVA) in 4 m, 80 cm, 60 cm, and 40 cm; slit-lamp examination; monocular and binocular defocus curve, binocular contrast sensitivity (CS), and a questionnaire on subjective quality of vision, optical phenomena, and spectacle independence.

Results

Binocular UDVA was −0.01 ± 0.08 logMAR in 4 m, 0.04 ± 0.13 logMAR in 80 cm, 0.23 ± 0.15 logMAR in 60 cm, and 0.25 ± 0.17 logMAR in 40 cm distance. Binocular defocus curve showed a visual acuity of −0.02 logMAR to 0.22 logMAR between 0.00 D (far) and −2.00 D (50 cm). CS under photopic and mesopic conditions without and with glare was 1.29 ± 0.30 logCS, 0.80 ± 0.09 logCS, 0.75 ± 0.11 logCS, respectively. Then, 65% of patients needed glasses for reading and 25% required the spectacles to perform tasks at intermediate distance after surgery. Despite some optical phenomena, 75% of patients would choose the same IOL again and 75% also recommend it to others.

Conclusions

Visual performance this extended depth of focus IOL showed good uncorrected binocular VA at far and 80 cm distance (

Autor:innen und Institutionen

  • Goethe University Frankfurt, Department of Opththalmology, Germany, Frankfurt.

ORCID-Profile: Thomas Kohnen

Zitieren

APA

Kohnen, T., Petermann, K., Hemkeppler, E., Lwowski, C., & Böhm, M. (2026). Clinical Outcome and Patient Reported Performance of a Partial Range of Focus Intraocular Lens after Bilateral Implantation. Klinische Monatsblätter für Augenheilkunde. https://doi.org/10.1055/a-2976-1869

Vancouver

Kohnen T, Petermann K, Hemkeppler E, Lwowski C, Böhm M. Clinical Outcome and Patient Reported Performance of a Partial Range of Focus Intraocular Lens after Bilateral Implantation. Klinische Monatsblätter für Augenheilkunde. 2026. doi:10.1055/a-2976-1869

BibTeX
@article{Kohnen2026,
  author = {Kohnen, Thomas and Petermann, Kerstin and Hemkeppler, Eva and Lwowski, Christoph and Böhm, Myriam},
  title = {Clinical Outcome and Patient Reported Performance of a Partial Range of Focus Intraocular Lens after Bilateral Implantation},
  journal = {Klinische Monatsblätter für Augenheilkunde},
  year = {2026},
  doi = {10.1055/a-2976-1869}
}
Kostenlos starten →