Mechanical Aortic Valve Replacement in Congenital Heart Disease Using the SJM Valve

Theresa Holst iD, Tomislav Cvitkovic iD, Murat Avsar, Dmitry Bobylev iD, Dietmar Boethig, Samir Sarikouch, Mechthild Westhoff-Bleck, Philipp Beerbaum, Arjang Ruhparwar, Alexander Horke

The Thoracic and Cardiovascular Surgeon · 01.01.2026 · 74 (S 03 S 03) · e23-e30

DOI: 10.1055/a-2960-9423 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift The Thoracic and Cardiovascular Surgeon, erschienen am 01.01.2026. Verfasst von Theresa Holst und 9 weiteren Autor:innen. Beteiligte Einrichtung: Hannover Medical School, Department of Cardiac, Thoracic, Transplantation and Vascular Surgery, Lower Saxony, Germany, Hanover. Hauptthemen laut MEDLINE: Heart Valve Prosthesis, Heart Defects, Congenital, Heart Valve Prosthesis Implantation, Aortic Valve. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Mechanical aortic valve replacement (mAVR) with the St. Jude Medical (SJM) prosthesis is an established treatment. However, data on prosthesis-related adverse events in patients with congenital heart disease (CHD) and aortic valve pathology are scarce. This single-center, retrospective, observational study included all CHD patients aged ≤ 45 years who underwent mAVR with an SJM prosthesis between 1993 and 2020. Survival and valve-related complications, including thromboembolism, bleeding, endocarditis, stenosis, regurgitation, and reoperation, were assessed. Kaplan–Meier analyses were performed to estimate time-dependent freedom from events. A total of 54 patients (mean age at surgery: 21 ± 9 years; 80% male) with a mean follow-up of 8.9 ± 6.6 years were included. Survival was 95.5% at 5 years and 91.9% at 10 and 15 years postoperatively. Relevant, interestingly often only transient, valvular dysfunction defined as peak gradient ≥ 50 mm Hg and/or ≥ moderate regurgitation occurred in 22% of patients. Freedom from prosthesis explantation was 97.4% at 5 and 10 years and 93.1% at 15 years. Freedom from anticoagulation-related events at 5, 10, and 15 years was 95.3%, 88.9%, and 84.9%, respectively. Freedom from prosthetic valve endocarditis was 97.4% at 5 years, 94.7% at 10 years, and 90.4% at 15 years. SJM mechanical aortic valve replacement in pediatric and young adult patients with CHD demonstrated favorable midterm survival, low reoperation rates, and acceptable prosthesis-related morbidity. Prosthetic valve dysfunction was frequently transient and rarely required reoperation, supporting SJM valves as a durable option with appropriate prosthesis sizing, anticoagulation, and long-term follow-up.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart Valve ProsthesisHeart Defects, CongenitalHeart Valve Prosthesis ImplantationAortic ValveHumansProsthesis DesignRetrospective StudiesTime FactorsMaleAdultFemaleRisk FactorsYoung AdultAdolescentChildPostoperative ComplicationsTreatment OutcomeRisk AssessmentRecovery of FunctionReoperationMiddle Aged

Autor:innen und Institutionen

  • Hannover Medical School, Department of Cardiac, Thoracic, Transplantation and Vascular Surgery, Lower Saxony, Germany, Hanover.
  • Hannover Medical School, Department of Pediatric Cardiology and Intensive Care Medicine, Lower Saxony, Germany, Hanover.
  • Hannover Medical School, Department of Cardiology and Angiology, Lower Saxony, Germany, Hanover.

ORCID-Profile: Theresa Holst, Tomislav Cvitkovic, Dmitry Bobylev

Zitieren

APA

Holst, T., Cvitkovic, T., Avsar, M., Bobylev, D., Boethig, D., Sarikouch, S., Westhoff-Bleck, M., Beerbaum, P., Ruhparwar, A., & Horke, A. (2026). Mechanical Aortic Valve Replacement in Congenital Heart Disease Using the SJM Valve. The Thoracic and Cardiovascular Surgeon, 74(S 03 S 03), e23-e30. https://doi.org/10.1055/a-2960-9423

Vancouver

Holst T, Cvitkovic T, Avsar M, Bobylev D, Boethig D, Sarikouch S, et al. Mechanical Aortic Valve Replacement in Congenital Heart Disease Using the SJM Valve. The Thoracic and Cardiovascular Surgeon. 2026;74(S 03 S 03):e23-e30. doi:10.1055/a-2960-9423

BibTeX
@article{Holst2026,
  author = {Holst, Theresa and Cvitkovic, Tomislav and Avsar, Murat and Bobylev, Dmitry and Boethig, Dietmar and Sarikouch, Samir and Westhoff-Bleck, Mechthild and Beerbaum, Philipp and Ruhparwar, Arjang and Horke, Alexander},
  title = {Mechanical Aortic Valve Replacement in Congenital Heart Disease Using the SJM Valve},
  journal = {The Thoracic and Cardiovascular Surgeon},
  year = {2026},
  volume = {74},
  number = {S 03 S 03},
  pages = {e23--e30},
  doi = {10.1055/a-2960-9423}
}
Kostenlos starten →