Guidance Imaging Modality Influences Pulsed-Wave Doppler Measurements: Comparative Evaluation of B-mode, Power Doppler, CCDS, MVI, and B-Flow

Christian Jacke, Christine Angermund, Berthold Stegemann iD, Emilia Stegemann iD

Ultraschall in der Medizin - European Journal of Ultrasound · 17.06.2026

DOI: 10.1055/a-2885-2749 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Ultraschall in der Medizin - European Journal of Ultrasound, erschienen am 17.06.2026. Verfasst von Christian Jacke und 3 weiteren Autor:innen. Beteiligte Einrichtung: Alfried Krupp Hospital Essen-Rüttenscheid, Department of Vascular Surgery and Angiology, North Rhine-Westphalia, Germany, Essen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Pulsed-wave (pw) Doppler is widely used for quantitative blood flow assessment, but its accuracy depends on the guidance imaging modality used to position the sample volume. Modern ultrasound systems provide several guidance modes – B-mode, color-coded duplex sonography (CCDS), power Doppler, B-flow, and microvascular imaging (MVI) – the influence of which on pw-Doppler measurements has not yet been systematically evaluated. Materials and Methods In this prospective paired-methods study, pw-Doppler flow of the brachial artery was measured in 454 adults while simultaneously using four guidance imaging modalities (CCDS, power Doppler, B-Flow, MVI). B-mode pw-Doppler measurements were interspersed as a reference. Differences in measured flow were analyzed using Bland-Altman statistics, analysis of variance, and linear mixed-effects models.

Results

CCDS, power Doppler, and B-flow produced pw-Doppler flow values closely matching the interpolated B-mode reference (bias < 6 mL/min). In contrast, MVI consistently underestimated flow (bias 50–60 mL/min, p < 0.001) and showed an additional flow-dependent bias. Bland–Altman analyses demonstrated markedly wider limits of agreement for MVI. No patient-related factors explained these deviations.

Conclusion

Guidance imaging modality significantly affects pw-Doppler flow measurements. MVI introduces systematic, flow-dependent underestimation, whereas CCDS, power Doppler, and B-flow yield consistent results. MVI should not be used when accurate pw-Doppler quantification is required.

Autor:innen und Institutionen

  • Alfried Krupp Hospital Essen-Rüttenscheid, Department of Vascular Surgery and Angiology, North Rhine-Westphalia, Germany, Essen.
  • Centre for Clinical Research Kassel, Clinical Research & Statistics, Germany, Kassel.
  • University of Marburg, Faculty of Medicine, Hesse, Germany, Marburg.
  • Agaplesion Diakonie Clinic Kassel, Department of Internal Medicine, Diabetology, Pulmonology and Angiology, Hesse, Germany, Kassel.
  • University Hospital of Giessen and Marburg Campus Marburg, Department of Cardiology, Angiology and Internal Medicine, Hesse, Germany, Marburg.

ORCID-Profile: Berthold Stegemann, Emilia Stegemann

Zitieren

APA

Jacke, C., Angermund, C., Stegemann, B., & Stegemann, E. (2026). Guidance Imaging Modality Influences Pulsed-Wave Doppler Measurements: Comparative Evaluation of B-mode, Power Doppler, CCDS, MVI, and B-Flow. Ultraschall in der Medizin - European Journal of Ultrasound. https://doi.org/10.1055/a-2885-2749

Vancouver

Jacke C, Angermund C, Stegemann B, Stegemann E. Guidance Imaging Modality Influences Pulsed-Wave Doppler Measurements: Comparative Evaluation of B-mode, Power Doppler, CCDS, MVI, and B-Flow. Ultraschall in der Medizin - European Journal of Ultrasound. 2026. doi:10.1055/a-2885-2749

BibTeX
@article{Jacke2026,
  author = {Jacke, Christian and Angermund, Christine and Stegemann, Berthold and Stegemann, Emilia},
  title = {Guidance Imaging Modality Influences Pulsed-Wave Doppler Measurements: Comparative Evaluation of B-mode, Power Doppler, CCDS, MVI, and B-Flow},
  journal = {Ultraschall in der Medizin - European Journal of Ultrasound},
  year = {2026},
  doi = {10.1055/a-2885-2749}
}
Kostenlos starten →