EUVIMEDEUVIMED entdecken
Validierungsstudie

Concurrent Validity and Reliability of an On-Floor 12 m Shuttle Run Test for Young Gymnasts

Lina Fay iD, Ludwig Rappelt, Steffen Held, Lars Donath

International Journal of Sports Medicine · 2026-11 · 47 (12) · 915-923

DOI: 10.1055/a-2884-0287 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift International Journal of Sports Medicine, online erschienen am 25.06.2026. Verfasst von Lina Fay und 3 weiteren Autor:innen. Beteiligte Einrichtung: Institute for Exercise Science and Sport Informatics, Department of Interventional Research in Exercise Science, Germany, Cologne. Hauptthemen laut MEDLINE: Gymnastics, Exercise Test, Running, Physical Endurance. Die Arbeit nennt 68 Literaturangaben. Gefördert von: Bundesinstitut für Sportwissenschaft.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Adequate endurance capacity is crucial for training quality, recovery, and long-term development of gymnasts. The shuttle run test is a valid and efficient field test for estimating aerobic capacity (i.e., maximum oxygen uptake) in children and adolescents. Adapted to the indoor restrictions of an artistic gymnastics floor, a feasible 12 m shuttle run test was examined for its validity and absolute and relative reliability. Young gymnasts (n = 69; age: 12.3±1.6 y; body mass index: 17.6±2.0 kg*m−2; training experience: 6.6±2.3 y), competing at trained and highly trained levels in artistic, trampoline, and rhythmic gymnastics, initially performed a laboratory treadmill test and two further 12 m shuttle run tests on a gymnastics floor. Oxygen uptake during laboratory and on-floor testing was assessed until objective exhaustion criteria were reached. The 12 m shuttle run test demonstrated good validity for relative maximal oxygen uptake (intraclass correlation coefficient2,1: 0.82 and 95% confidence interval: 0.72–0.88) with moderate limits of agreement (95% confidence interval: –10.7–9.2 mL*kg−1*min−1) between the treadmill and the 12 m shuttle run test. The test–retest reliability of the 12 m shuttle run test for relative maximal oxygen uptake was good (intraclass correlation coefficient2,1: 0.79, 95% confidence interval: 0.64–0.89). The on-floor 12 m shuttle run test serves as a sufficiently valid and reliable endurance testing tool, enabling the regular assessment with a potential classification of aerobic capacity requirements.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GymnasticsExercise TestRunningPhysical EnduranceHumansReproducibility of ResultsOxygen ConsumptionChildAdolescentFemale

Autor:innen und Institutionen

  • Institute for Exercise Science and Sport Informatics, Department of Interventional Research in Exercise Science, Germany, Cologne.
  • IST University of Applied Sciences, Sport and Management, Germany, Düsseldorf.

ORCID-Profile: Lina Fay

Förderung

  • Bundesinstitut für Sportwissenschaft

Zitieren

APA

Fay, L., Rappelt, L., Held, S., & Donath, L. (2026). Concurrent Validity and Reliability of an On-Floor 12 m Shuttle Run Test for Young Gymnasts. International Journal of Sports Medicine, 47(12), 915-923. https://doi.org/10.1055/a-2884-0287

Vancouver

Fay L, Rappelt L, Held S, Donath L. Concurrent Validity and Reliability of an On-Floor 12 m Shuttle Run Test for Young Gymnasts. International Journal of Sports Medicine. 2026;47(12):915-923. doi:10.1055/a-2884-0287

BibTeX
@article{Fay2026,
  author = {Fay, Lina and Rappelt, Ludwig and Held, Steffen and Donath, Lars},
  title = {Concurrent Validity and Reliability of an On-Floor 12 m Shuttle Run Test for Young Gymnasts},
  journal = {International Journal of Sports Medicine},
  year = {2026},
  volume = {47},
  number = {12},
  pages = {915--923},
  doi = {10.1055/a-2884-0287}
}
Kostenlos starten →