Test‐Retest Reliability of Physiological Resilience During and After Prolonged Moderate‐Intensity Running in Well‐Trained Runners
European Journal of Sport Science · 2026-05 · 26 (5)
DOI: 10.1002/ejsc.70178 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Sport Science, online erschienen am 28.04.2026. Verfasst von Timi Malinen und 4 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Sports and Health Sciences, University of Jyväskylä, Jyväskylä, Finland. Hauptthemen laut MEDLINE: Running, Physical Endurance. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 62 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Suomen urheilututkimussäätiö.
Abstract (Originalsprache)
In previous research, physiological resilience has been measured as deterioration of the physiological profile during prolonged exercise. This study aimed to evaluate the test–retest reliability of physiological resilience during prolonged moderate‐intensity running. Physiological profile of 26 well‐trained endurance runners (10 females) was tested in nonfatigued state as well as during and after two identical ∼2.5‐h long physiological resilience tests at ∼89% of VT1 (ventilatory threshold 1) speed within an average period of 13 days. Reliability was assessed with intraclass correlation coefficients (ICC), coefficient of variations (CV%), and typical errors (TE and TE%). Change in maximal speed achieved in the incremental test (sPeak) was the most reliable metric and showed good reliability (ICC: 0.81 and TE: 1.8). The drifts in running economy (RE) and the heart rate (HR) had moderate to good reliability in the second half of the trial (ICC: 0.52–0.80 and TE 1.7–2.4). The changes in maximal oxygen uptake (VO 2max ) and ventilatory thresholds (VTs) had poor reliability (ICC: 0.07–0.36 and TE: 3.5–4.6). However, the absolute values of these variables demonstrated good to excellent reliability in fatigued state (ICC > 0.83, TE% < 5.2%, and CV% < 4.1%) even though they significantly deteriorated. Determining changes in sPeak and drifts in RE and HR appears to be the most reliable method to measure physiological resilience. In contrast, measurement of the physiological profile remains reliable in fatigued state for every variable. Longer or more demanding protocols may be required to obtain greater reliability for deterioration of the physiological profile.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Faculty of Sports and Health Sciences, University of Jyväskylä, Jyväskylä, Finland.
- UKK Institute for Health Promotion Research, Tampere, Finland.
- Paavo Nurmi Centre and Unit for Health and Physical Activity, University of Turku, Turku, Finland.
- Department of Sports and Exercise Medicine, Clinicum, University of Helsinki, Helsinki, Finland.
- Helsinki Clinic for Sports and Exercise Medicine, Foundation for Sports and Exercise Medicine, Helsinki, Finland.
ORCID-Profile: Timi Malinen, Olli-Pekka Nuuttila
Förderung
- Suomen urheilututkimussäätiö
Zitieren
APA
Malinen, T., Nuuttila, O. P., Matomäki, P., Uusitalo, A., & Kyröläinen, H. (2026). Test‐Retest Reliability of Physiological Resilience During and After Prolonged Moderate‐Intensity Running in Well‐Trained Runners. European Journal of Sport Science, 26(5). https://doi.org/10.1002/ejsc.70178
Vancouver
Malinen T, Nuuttila OP, Matomäki P, Uusitalo A, Kyröläinen H. Test‐Retest Reliability of Physiological Resilience During and After Prolonged Moderate‐Intensity Running in Well‐Trained Runners. European Journal of Sport Science. 2026;26(5). doi:10.1002/ejsc.70178
BibTeX
@article{Malinen2026,
author = {Malinen, Timi and Nuuttila, Olli-Pekka and Matomäki, Pekka and Uusitalo, Arja and Kyröläinen, Heikki},
title = {Test‐Retest Reliability of Physiological Resilience During and After Prolonged Moderate‐Intensity Running in Well‐Trained Runners},
journal = {European Journal of Sport Science},
year = {2026},
volume = {26},
number = {5},
doi = {10.1002/ejsc.70178}
}
EUVIMED