Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.09.2026. Verfasst von Hidehito Sumiya und 6 weiteren Autor:innen. Beteiligte Einrichtung: Public Interest Incorporated Foundation Sendai City Medical Center, Gastroenterology, Miyagi Prefecture, Japan, Sendai. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) using a fully covered self-expandable metallic stent (FCSEMS) can cause segmental cholangitis due to the obstruction of upstream bile ducts or intrahepatic branch ducts.[ 1 ] [ 2 ] In addition, the removal of the FCSEMS before sufficient maturation of the endosonographically created route (ESCR) can carry a risk of bile leakage. We report a case of segmental cholangitis after EUS-HGS with FCSEMS placement that was managed by exchange to multiple plastic stents (PSs). An 86-year-old man with pancreatic head cancer underwent duodenal stent placement for duodenal stenosis, followed by EUS-HGS for obstructive jaundice. A FCSEMS (HANAROSTENT Biliary Full Cover Benefit, 8 mm×12 cm; Boston Scientific Japan K.K., Tokyo, Japan) was placed in the B2 bile duct across the ESCR. The day after EUS-HGS, the patient developed fever and abdominal pain. On computed tomography, the upstream B2 bile duct and its peripheral branches were filled with contrast medium, suggesting segmental cholangitis ([ Fig. 1 ]). Although conservative management was initiated, the cholangitis did not resolve. Therefore, stent exchange was performed 3 days after EUS-HGS. Fig. 1 Computed tomographic images acquired the day after endoscopic ultrasound-guided hepaticogastrostomy. The upstream B2 bile duct and its peripheral branches were filled with contrast medium. ( a ) Horizontal image. ( b ) Coronal image. After the removal of the FCSEMS, the gastric-side orifice of the ESCR was markedly dilated, and pneumoperitoneum was observed under fluoroscopy ([ Video 1 and ] [ Fig. 2a ]). After the placement of a 7-Fr PS (Through & Pass TYPE IT; Gadelius Medical K.K., Tokyo, Japan) across the ESCR, closure of the remaining gap at the orifice was attempted by using endoscopic clips. However, complete closure was technically difficult. To minimize the gap, two additional PSs (7- and 8.5-Fr) were placed across the ESCR ([ Fig. 2b, c ]). In addition, a nasogastric tube was inserted to minimize the leakage of the gastric juice through the ESCR. After the procedure, the cholangitis promptly resolved, and the patient was discharged without symptomatic bile leakage or other adverse events. Video 1 Demonstration of the rescue technique for segmental cholangitis after metallic stent placement in endoscopic ultrasound-guided hepaticogastrostomy. Download Video Fig. 2 Endoscopic procedure for segmental cholangitis. ( a ) After the removal of the fully covered self-expandable metallic stent, pneumoperitoneum progressively worsened (arrowhead). ( b ) Three plastic stents were placed at the endosonographically created route. ( c ) The pneumoperitoneum gradually decreased. Endoscopy_UCTN_Code_CPL_1AL_2AD Publication History Received: 22 April 2026 Accepted: 25 May 2026 Article published online: 23 June 2026 © 2026. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
Autor:innen und Institutionen
- Public Interest Incorporated Foundation Sendai City Medical Center, Gastroenterology, Miyagi Prefecture, Japan, Sendai.
ORCID-Profile: Hidehito Sumiya, Shinsuke Koshita, Yoshihide Kanno, Takahisa Ogawa
Zitieren
APA
Sumiya, H., Koshita, S., Kanno, Y., Ogawa, T., Kusunose, H., Yonamine, K., & Ito, K. (2026). A rescue technique for segmental cholangitis after metallic stent placement in endoscopic ultrasound-guided hepaticogastrostomy. Endoscopy, 58(S 04 S 04), E747-E748. https://doi.org/10.1055/a-2883-0988
Vancouver
Sumiya H, Koshita S, Kanno Y, Ogawa T, Kusunose H, Yonamine K, et al. A rescue technique for segmental cholangitis after metallic stent placement in endoscopic ultrasound-guided hepaticogastrostomy. Endoscopy. 2026;58(S 04 S 04):E747-E748. doi:10.1055/a-2883-0988
BibTeX
@article{Sumiya2026,
author = {Sumiya, Hidehito and Koshita, Shinsuke and Kanno, Yoshihide and Ogawa, Takahisa and Kusunose, Hiroaki and Yonamine, Keisuke and Ito, Kei},
title = {A rescue technique for segmental cholangitis after metallic stent placement in endoscopic ultrasound-guided hepaticogastrostomy},
journal = {Endoscopy},
year = {2026},
volume = {58},
number = {S 04 S 04},
pages = {E747--E748},
doi = {10.1055/a-2883-0988}
}
EUVIMED