Anchoring wire technique for additional stent placement after endoscopic ultrasonography-guided hepaticogastrostomy
Endoscopy · 01.12.2025 · 57 (S 01 S 01) · E829-E830
DOI: 10.1055/a-2643-8405 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.12.2025. Verfasst von Kazuki Endo und 6 weiteren Autor:innen. Beteiligte Einrichtung: Gastroenterological Center, Yokohama City University Medical Center, Yokohama, Japan. Die Arbeit nennt 4 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Endoscopic ultrasonography-guided hepaticogastrostomy (EUS-HGS) has been reported to have a high technical success rate; however, severe complications occasionally occur [ 1 ]. Among these, migration of a self-expandable metal stent (SEMS) into the abdominal cavity during and after EUS-HGS is a potentially fatal complication [ 2 ] [ 3 ]. In cases where the SEMS becomes partially dislodged toward the abdominal cavity, resulting in a shortened intragastric length, additional SEMS placement has been reported [ 4 ]; however, it carries the risk of pushing the SEMS into the abdominal cavity. Herein, we report a novel anchoring wire technique during additional SEMS placement after EUS-HGS ([ Video 1 ]). Download Video An additional SEMS was safely placed using the anchoring wire method for the partially dislodged SEMS after EUS-HGS.Video 1 A 71-year-old man with unresectable ampullary carcinoma was admitted for cholangitis due to occlusion of SEMS. Endoscopic retrograde cholangiopancreatography was performed; however, additional SEMS placement failed due to tumor invasion in the second portion of the duodenum. Therefore, EUS-HGS was performed after nasobiliary drainage, and a fully covered SEMS (HANARO Benefit, 8-mm, 12-cm; Boston Scientific, Marlborough, Massachusetts, USA) was deployed in B3. The following day, computed tomography images revealed that the gastric side of the SEMS had partially dislodged toward the abdominal cavity ([ Fig. 1 ]). An emergency endoscopic reintervention was performed for additional SEMS placement. The stent cover was penetrated using a tapered catheter, and the sufficient length of a 0.025-inch guidewire (VisiGlide 2, Olympus medical systems, Tokyo, Japan) was inserted through the mesh gap and left in the stomach as an anchoring wire. Subsequently, a second guidewire was advanced into the SEMS from the gastric end, and an additional SEMS, identical to the previous stent, was successfully deployed without stent migration ([ Fig. 2 ]). Fig. 1 Computed tomography on the day after EUS-HGS reveals that the gastric side of the SEMS is partially dislodged toward the abdominal cavity (arrowhead). Fig. 2 Additional SEMS placement using anchoring wire method. a Silicon cover of the SEMS is penetrated using a tapered catheter and a 0.025-inch guidewire is inserted through the mesh gap. b A sufficient length of the guidewire is left in the stomach. c A delivery system of the additional SEMS is inserted from the gastric end. d The anchoring wire is removed just before the additional SEMS placement and the additional SEMS is successfully placed. To the best of our knowledge, this is the first report of novel anchoring wire technique to prevent SEMS migration during reintervention after EUS-HGS. This method is useful as a rescue technique for additional SEMS placement. Endoscopy_UCTN_Code_TTT_1AS_2AH Endoscopy E-Videos https://eref.thieme.de/e-videos E-Videos is an open access online section of the journal Endoscopy , reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high-quality video and are published with a Creative Commons CC-BY license. Endoscopy E-Videos qualify for HINARI discounts and waivers and eligibility is automatically checked during the submission process. We grant 100% waivers to articles whose corresponding authors are based in Group A countries and 50% waivers to those who are based in Group B countries as classified by Research4Life (see: https://www.research4life.org/access/eligibility/ ). This section has its own submission website at https://mc.manuscriptcentral.com/e-videos . Publication History Article published online: 25 July 2025 © 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
Autor:innen und Institutionen
- Gastroenterological Center, Yokohama City University Medical Center, Yokohama, Japan.
- Department of Gastroenterology, Yokohama City University, School of Medicine, Yokohama, Japan.
ORCID-Profile: Kazuki Endo, Haruo Miwa, Yuichi Suzuki
Zitieren
APA
Endo, K., Miwa, H., Oishi, R., Suzuki, Y., Sugimori, K., Numata, K., & Maeda, S. (2025). Anchoring wire technique for additional stent placement after endoscopic ultrasonography-guided hepaticogastrostomy. Endoscopy, 57(S 01 S 01), E829-E830. https://doi.org/10.1055/a-2643-8405
Vancouver
Endo K, Miwa H, Oishi R, Suzuki Y, Sugimori K, Numata K, et al. Anchoring wire technique for additional stent placement after endoscopic ultrasonography-guided hepaticogastrostomy. Endoscopy. 2025;57(S 01 S 01):E829-E830. doi:10.1055/a-2643-8405
BibTeX
@article{Endo2025,
author = {Endo, Kazuki and Miwa, Haruo and Oishi, Ritsuko and Suzuki, Yuichi and Sugimori, Kazuya and Numata, Kazushi and Maeda, Shin},
title = {Anchoring wire technique for additional stent placement after endoscopic ultrasonography-guided hepaticogastrostomy},
journal = {Endoscopy},
year = {2025},
volume = {57},
number = {S 01 S 01},
pages = {E829--E830},
doi = {10.1055/a-2643-8405}
}
EUVIMED