A novel endoscopic plastic stent exchange technique using a loop cutter in malignant afferent loop obstruction: a method applicable to various pancreatobiliary situations
Endoscopy · 01.06.2026 · 58 (S 02 S 02) · E546-E547
DOI: 10.1055/a-2849-8990 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.06.2026. Verfasst von Akinobu Koiwai und 5 weiteren Autor:innen. Beteiligte Einrichtung: Tohoku Medical and Pharmaceutical University, Division of Gastroenterology, Japan, Sendai City. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Malignant afferent loop obstruction (ALO) after Billroth-II gastrectomy may cause perforation, cholangitis, or pancreatitis if decompression is delayed [ 1 ] [ 2 ]. A plastic stent (PS) is used for palliation, but once the stent is occluded, re-intervention can be challenging when the afferent limb orifice is obscured [ 1 ] [ 3 ] [ 4 ]. In such situations, blind stent removal risks loss of access. Our patient underwent distal gastrectomy (Billroth-II reconstruction) for gastric cancer. Four years later, peritoneal dissemination caused obstruction. Efferent loop obstruction at the gastrojejunostomy ([ Fig. 1 ] a ) was treated with a self-expandable metallic stent (SEMS, HANAROSTENT Naturfit-Duo, BostonScientific, MA, USA; 22 mm × 10 cm), and a prophylactic double-pigtail PS (AdvaniX-J, BostonScientific; 7 Fr × 10 cm) was placed in the afferent loop ([ Fig. 1 ] b and c ). However, after the placement of the SMES and PS, the patient developed recurrent ALO due to PS occlusion ([ Fig. 1 ] d ), and at re-intervention the afferent orifice was no longer visible endoscopically ([ Fig. 2 ] a ). Fig. 1 a CT showing efferent loop obstruction at the gastrojejunostomy due to peritoneal dissemination. b A fluoroscopic image demonstrating the deployment of a SEMS across the efferent limb stricture. c An endoscopic view showing the SMES in the efferent limb and the placement of a prophylactic double-pigtail plastic stent in the afferent limb. d CT obtained 4 months later showing marked dilation of the afferent loop caused by occlusion of the indwelling plastic stent. CT, computed tomography; SEMS, self-expandable metallic stent. Fig. 2 a–c Endoscopic images. a An endoscopic view showing that the afferent limb orifice was no longer visible because of tumor progression and expansion of the efferent limb metallic stent. b A loop cutter was applied to the midportion of the indwelling plastic stent to create a small fenestration. c An endoscopic view confirming the passage of a 0.025-inch guidewire through the fenestration into the afferent limb. d–e Fluoroscopic images. d A fluoroscopic image showing the guidewire advanced through the fenestrated plastic stent into the dilated afferent loop. e Fluoroscopic removal of the occluded plastic stent over the indwelling guidewire. f Macroscopic appearance of the removed double-pigtail plastic stent, showing the segment that was fenestrated using the loop cutter. Under fluoroscopic guidance, we created a fenestration at the midportion of the indwelling PS using a loop cutter (FS-5Q-1, Olympus, Tokyo, Japan Video image; [ Fig. 2 ]b). The PS was not completely transected; leaving a partial hinge maintains alignment and facilitates guidewire direction into the lumen. A 0.025-inch guidewire was then advanced through the fenestration ([ Fig. 2 ]c and d). Once the wire position was confirmed, the occluded PS was removed with forceps ([ Fig. 2 ]e and f), and contrast injection through a catheter confirms correct positioning within the afferent limb ([ Fig. 3 ]a). We placed two guidewires and a new PS and a nasobiliary drainage tube are inserted ([ Fig. 3 ]b and c, [ Video 1 ]). Fig. 3 a After exchange to a catheter, contrast injection confirms opacification of the afferent limb, demonstrating the correct positioning of the guidewire and catheter. b A fluoroscopic image demonstrating the placement of the new double-pigtail stent into the afferent limb. c A fluoroscopic image showing the additional placement of a nasobiliary drainage tube alongside the new plastic stent. Download Video Loop cutter–assisted fenestration of an indwelling plastic stent allows guidewire passage and safe exchange to a new double-pigtail stent in malignant afferent loop obstruction after Billroth-II gastrectomy.Video 1 This simple technique preserves the existing tract avoiding losing the only safe access route. We consider loop cutter-assisted fenestration as a salvage option not only for malignant ALO but also for PS exchanges in the pancreatobiliary field, such as occluded stents after endoscopic ultrasonography-guided biliary drainage or pancreatic duct drainage. Endoscopy_UCTN_Code_TTT_1AR_2A Publication History Article published online: 24 April 2026 © 2026. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
Autor:innen und Institutionen
- Tohoku Medical and Pharmaceutical University, Division of Gastroenterology, Japan, Sendai City.
ORCID-Profile: Akinobu Koiwai, Morihisa Hirota, Nana Inomata, Yuki Miyashita, Kennichi Satoh
Zitieren
APA
Koiwai, A., Hirota, M., Inomata, N., Miyashita, Y., Itoh, T., & Satoh, K. (2026). A novel endoscopic plastic stent exchange technique using a loop cutter in malignant afferent loop obstruction: a method applicable to various pancreatobiliary situations. Endoscopy, 58(S 02 S 02), E546-E547. https://doi.org/10.1055/a-2849-8990
Vancouver
Koiwai A, Hirota M, Inomata N, Miyashita Y, Itoh T, Satoh K. A novel endoscopic plastic stent exchange technique using a loop cutter in malignant afferent loop obstruction: a method applicable to various pancreatobiliary situations. Endoscopy. 2026;58(S 02 S 02):E546-E547. doi:10.1055/a-2849-8990
BibTeX
@article{Koiwai2026,
author = {Koiwai, Akinobu and Hirota, Morihisa and Inomata, Nana and Miyashita, Yuki and Itoh, Takehito and Satoh, Kennichi},
title = {A novel endoscopic plastic stent exchange technique using a loop cutter in malignant afferent loop obstruction: a method applicable to various pancreatobiliary situations},
journal = {Endoscopy},
year = {2026},
volume = {58},
number = {S 02 S 02},
pages = {E546--E547},
doi = {10.1055/a-2849-8990}
}
EUVIMED