EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Metal stent versus plastic stent in endoscopic ultrasound‐guided hepaticogastrostomy for unresectable malignant biliary obstruction: Large single‐center retrospective comparative study

Daiki Yamashige iD, Susumu Hijioka iD, Yoshikuni Nagashio, Yuta Maruki, Yasuhiro Komori, Masaru Kuwada, Soma Fukuda, Shin Yagi, Kohei Okamoto, Daiki Agarie, Mark Chatto, Chigusa Morizane und 5 weitere

Digestive Endoscopy · 2025-01 · 37 (1) · 117-129

DOI: 10.1111/den.14956 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Digestive Endoscopy, online erschienen am 15.11.2024. Verfasst von Daiki Yamashige und 16 weiteren Autor:innen. Beteiligte Einrichtung: Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo, Japan. Hauptthemen laut MEDLINE: Cholestasis, Stents, Endosonography, Plastics. Die Arbeit wurde bisher 24-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The National Cancer Center Research and Development Fund.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Whether metal stents (MS) or plastic stents (PS) yield better outcomes for malignant biliary obstruction in endoscopic ultrasound‐guided hepaticogastrostomy (EUS‐HGS) is controversial. We aimed to compare outcomes of initial EUS‐HGS performed with MS or PS. Method s In this single‐center retrospective study, we included patients (MS/PS groups: n = 151/72) with unresectable malignant biliary obstruction and performed multivariable analysis. The landmark date was defined as day 100 and used to evaluate the time to recurrent biliary obstruction (TRBO).

Results

The clinical success rate was similar in both groups. The mean total bilirubin percentage decrease at week 2 was significantly higher in the MS group than in the PS group (−45.1% vs. −23.7%, P = 0.016). Median TRBO was significantly different between the MS and PS groups (183 and 92 days, respectively; P = 0.017). TRBO within 100 days was comparable in both groups but was significantly shorter only after 100 days in the PS group (adjusted hazard ratio 12.8, P < 0.001). Adverse events were significantly more common in the MS group (23.8% vs. 9.7%, P = 0.012), although they occurred relatively frequently even with PS in the cholangitis subgroup ( P interaction = 0.034). After endoscopic re‐intervention, TRBO tended to be longer with revision PS (hazard ratio 0.40, P = 0.47).

Conclusions

Although MS provided early improvement of jaundice and long stent patency, PS provided a better safety profile and comparable stent patency until 100 days. PS might also be an adequate and optimal palliation method in EUS‐HGS.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CholestasisStentsEndosonographyPlasticsGastrostomyHumansRetrospective StudiesMaleFemaleAgedMiddle AgedMetalsBile Duct NeoplasmsTreatment OutcomeAged, 80 and overUltrasonography, InterventionalAnastomosis, SurgicalPalliative Care

Stichwörter der Autor:innen

hepaticogastrostomyinterventional EUSsafetystent

Substanzen

PlasticsMetals

Autor:innen und Institutionen

  • Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo, Japan.
  • Section of Gastroenterology, Department of Medicine, Makati Medical Center, Manila, Philippines.
  • Department of Diagnostic Radiology, National Cancer Center Hospital, Tokyo, Japan.
  • Endoscopy Division, National Cancer Center Hospital, Tokyo, Japan.

ORCID-Profile: Daiki Yamashige, Susumu Hijioka, Yutaka Saito

Förderung

  • The National Cancer Center Research and Development Fund

Zitieren

APA

Yamashige, D., Hijioka, S., Nagashio, Y., Maruki, Y., Komori, Y., Kuwada, M., Fukuda, S., Yagi, S., Okamoto, K., Agarie, D., Chatto, M., Morizane, C., Ueno, H., Sugawara, S., Sone, M., Saito, Y., & Okusaka, T. (2025). Metal stent versus plastic stent in endoscopic ultrasound‐guided hepaticogastrostomy for unresectable malignant biliary obstruction: Large single‐center retrospective comparative study. Digestive Endoscopy, 37(1), 117-129. https://doi.org/10.1111/den.14956

Vancouver

Yamashige D, Hijioka S, Nagashio Y, Maruki Y, Komori Y, Kuwada M, et al. Metal stent versus plastic stent in endoscopic ultrasound‐guided hepaticogastrostomy for unresectable malignant biliary obstruction: Large single‐center retrospective comparative study. Digestive Endoscopy. 2025;37(1):117-129. doi:10.1111/den.14956

BibTeX
@article{Yamashige2025,
  author = {Yamashige, Daiki and Hijioka, Susumu and Nagashio, Yoshikuni and Maruki, Yuta and Komori, Yasuhiro and Kuwada, Masaru and Fukuda, Soma and Yagi, Shin and Okamoto, Kohei and Agarie, Daiki and Chatto, Mark and Morizane, Chigusa and Ueno, Hideki and Sugawara, Shunsuke and Sone, Miyuki and Saito, Yutaka and Okusaka, Takuji},
  title = {Metal stent versus plastic stent in endoscopic ultrasound‐guided hepaticogastrostomy for unresectable malignant biliary obstruction: Large single‐center retrospective comparative study},
  journal = {Digestive Endoscopy},
  year = {2025},
  volume = {37},
  number = {1},
  pages = {117--129},
  doi = {10.1111/den.14956}
}
Kostenlos starten →