Impact of Wearing a Face Mask on the Reliability of Standard Automated Perimetry in Glaucoma Patients and Suspects: a Retrospective Longitudinal Study
Klinische Monatsblätter für Augenheilkunde · 22.06.2026
DOI: 10.1055/a-2823-2534 ↗Kurz gefasst
Fachartikel in der Zeitschrift Klinische Monatsblätter für Augenheilkunde, erschienen am 22.06.2026. Verfasst von Philip Keye und 5 weiteren Autor:innen. Beteiligte Einrichtung: Eye Center, Medical Center, University of Freiburg, Germany.
Abstract (Originalsprache)
Purpose
To assess the reliability of standard automated perimetry in a real-life cohort of glaucoma patients and suspects wearing face masks due to the COVID-19 pandemic in a large German eye hospital.
Methods
Data of 160 eyes of 83 glaucoma patients and suspects who received at least one visual field examination and optical coherence tomography for glaucoma monitoring in 2018, 2019 and 2020 were included. Mean visual field defect and the rates of false-positive and false-negative responses between tests without (2019) and tests with a face mask (2020) were compared. Mean retinal nerve fibre layer thickness and the minimum rim width of Bruchʼs membrane opening served as a control for glaucoma progression.
Results
No statistically significant difference between visual fields without a face mask, and examinations with a face mask could be detected for mean defect (p = 0.075), rate of false-positives (p = 0.7) and rate of false-negatives (p = 0.16).
Conclusion
Our data suggest that protective face mask wear does not impair the quality and reliability of standard automated perimetry in a real-life cohort of glaucoma patients and glaucoma suspects.
Autor:innen und Institutionen
- Eye Center, Medical Center, University of Freiburg, Germany.
- Ophthalmology Centre at the St Franziskus-Hospital Münster, Germany.
ORCID-Profile: Philip Keye, Jan Luebke
Zitieren
APA
Keye, P., Martin, J., Evers, C., Böhringer, D., Reinhard, T., & Luebke, J. (2026). Impact of Wearing a Face Mask on the Reliability of Standard Automated Perimetry in Glaucoma Patients and Suspects: a Retrospective Longitudinal Study. Klinische Monatsblätter für Augenheilkunde. https://doi.org/10.1055/a-2823-2534
Vancouver
Keye P, Martin J, Evers C, Böhringer D, Reinhard T, Luebke J. Impact of Wearing a Face Mask on the Reliability of Standard Automated Perimetry in Glaucoma Patients and Suspects: a Retrospective Longitudinal Study. Klinische Monatsblätter für Augenheilkunde. 2026. doi:10.1055/a-2823-2534
BibTeX
@article{Keye2026,
author = {Keye, Philip and Martin, Julien and Evers, Charlotte and Böhringer, Daniel and Reinhard, Thomas and Luebke, Jan},
title = {Impact of Wearing a Face Mask on the Reliability of Standard Automated Perimetry in Glaucoma Patients and Suspects: a Retrospective Longitudinal Study},
journal = {Klinische Monatsblätter für Augenheilkunde},
year = {2026},
doi = {10.1055/a-2823-2534}
}
EUVIMED