EUVIMEDEUVIMED entdecken
Crossref

To Study Short-Term Effect of Standard Automated Perimetry Testing On Intraocular Pressure in Patient With Glaucoma

R V Pathakjee, Drashti Patel, Karan Maniar, Purva Shah, Jaini Shah

International Journal of Drug Delivery Technology · 02.06.2026 · 16 (43s)

DOI: 10.25258/ijddt.16.43s.148 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Drug Delivery Technology, online erschienen am 02.06.2026. Verfasst von R V Pathakjee und 4 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Visual field testing is often performed on glaucoma patients just before the ophthalmological consultation because VF analysis is essential for identifying glaucoma development and avoiding abnormal VF results associated with an earlier eye examination.

Objectives

The present study was conducted to find changes in IOP measurement after Humphrey perimetry in patients with glaucoma & To study relation of IOP with different strategy of Humphrey perimetry. Seventy patients with glaucomatous changes were included and analysed in the present study. Materials and Methods: The cross-sectional study was conducted among 70 patients with high intraocular pressure. They all were undergone complete ophthalmic evaluation along with detailed Ocular and medical history followed by examination and measurements. Visual field-testing Humphrey Perimetry with various protocols. IOP was measured by Goldmann applanation tonometer before and after visual field testing.

Results

Before perimetry, the mean intraocular pressure in the right eye among study participants was 20.20 mmHg (SD 4.98 mmHg); in the left, it was 19.67 mmHg (SD 3.67 mmHg). The mean intraocular pressure in the right eye among study participants after 2 minutes of perimetry was 21.15 mmHg (SD 4.47 mmHg); in the left, it was 20.67 mmHg (SD 3.59 mmHg). In the present study, IOP was significantly higher among study participants after perimetry in both eyes. Humphrey perimetry with full threshold was used among 21.4% of the patients. SITA standard 24-2 and SITA fast 24-2 was used among 52.9% and 7.1% of the study participants, respectively. SITA standard 10-2 and Full threshold 10-2 was employed among 12.9% and 5.7% of the patients, respectively.

Conclusion

In present study, intraocular pressure after Humphrey perimetry is significantly increased among glaucoma patients. Compared to the SITA Standard 24-2,10-2 and SITA fast, the Full Threshold 30-2 & 10-2 takes more time to complete, increasing the likelihood of an increase in intraocular pressure.

Zitieren

APA

Pathakjee, R. V., Patel, D., Maniar, K., Shah, P., & Shah, J. (2026). To Study Short-Term Effect of Standard Automated Perimetry Testing On Intraocular Pressure in Patient With Glaucoma. International Journal of Drug Delivery Technology, 16(43s). https://doi.org/10.25258/ijddt.16.43s.148

Vancouver

Pathakjee RV, Patel D, Maniar K, Shah P, Shah J. To Study Short-Term Effect of Standard Automated Perimetry Testing On Intraocular Pressure in Patient With Glaucoma. International Journal of Drug Delivery Technology. 2026;16(43s). doi:10.25258/ijddt.16.43s.148

BibTeX
@article{Pathakjee2026,
  author = {Pathakjee, R V and Patel, Drashti and Maniar, Karan and Shah, Purva and Shah, Jaini},
  title = {To Study Short-Term Effect of Standard Automated Perimetry Testing On Intraocular Pressure in Patient With Glaucoma},
  journal = {International Journal of Drug Delivery Technology},
  year = {2026},
  volume = {16},
  number = {43s},
  doi = {10.25258/ijddt.16.43s.148}
}
Kostenlos starten →