EUVIMEDEUVIMED entdecken
Crossref

The Equivalence of Fetal Heart Rate Variability and Accelerations in the Interpretation of Non-Stress Tests

Grace J Johnson, Alison N Goulding, Stacie G Denning, Steven L Clark

American Journal of Perinatology · 2026-09 · 43 (12) · 1673-1677

DOI: 10.1055/a-2814-9328 ↗

Kurz gefasst

Fachartikel in der Zeitschrift American Journal of Perinatology, online erschienen am 12.03.2026. Verfasst von Grace J Johnson und 3 weiteren Autor:innen. Beteiligte Einrichtung: Baylor College of Medicine and Texas Children's Hospital, Houston, Texas, United States. Hauptthemen laut MEDLINE: Heart Rate, Fetal, Fetal Monitoring, Cardiotocography. Die Arbeit nennt 25 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accelerations were initially chosen as the basis for non-stress test (NST) interpretation against a background of significant artifact present in the first-generation, non-autocorrelated fetal monitors that made the interpretation of variability with external fetal heart rate (FHR) monitoring unreliable. Since moderate variability and accelerations are both physiologically similar and equally indicative of a non-acidemic fetus, we hypothesized that interpreting NSTs based on variability rather than accelerations would produce similar results. We performed a retrospective cohort study of singleton fetuses undergoing antenatal testing in our system between 2011 and 2022. Data regarding the interpretation of NSTs were extracted and non-reactive tests were identified. For patients with non-reactive NSTs, data regarding follow-up testing were collected. Our cohort included 76,232 total NSTs performed on 22,619 patients at increased risk of fetal demise, of which 1,662 (2%) were found to be non-reactive. Of the non-reactive tests, 1,499 (90%) were interpreted as having moderate variability, 114 (7%) had minimal or absent variability, and in 49 (3%), the variability was uncertain. Data regarding follow-up testing were available for 1,480 of the 1,499 non-reactive tests with moderate variability. In this group, 1,476 (99%) went on to have either reassuring follow-up testing. The four infants (0.3%) who failed to have a reassuring follow-up test all had major anomalies. In nonanomalous fetuses, moderate variability in an otherwise non-reactive NST was invariably followed by a reassuring test of fetal well-being. These data confirm basic science observations regarding FHR regulation and suggest that, in the presence of moderate variability during an otherwise non-reactive NST, additional follow-up testing may not be necessary. Such an approach would avoid the need for additional testing in 90% of fetuses with non-reactive NSTs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart Rate, FetalFetal MonitoringCardiotocographyHumansFemaleRetrospective StudiesPregnancy

Autor:innen und Institutionen

  • Baylor College of Medicine and Texas Children's Hospital, Houston, Texas, United States.

Zitieren

APA

Johnson, G. J., Goulding, A. N., Denning, S. G., & Clark, S. L. (2026). The Equivalence of Fetal Heart Rate Variability and Accelerations in the Interpretation of Non-Stress Tests. American Journal of Perinatology, 43(12), 1673-1677. https://doi.org/10.1055/a-2814-9328

Vancouver

Johnson GJ, Goulding AN, Denning SG, Clark SL. The Equivalence of Fetal Heart Rate Variability and Accelerations in the Interpretation of Non-Stress Tests. American Journal of Perinatology. 2026;43(12):1673-1677. doi:10.1055/a-2814-9328

BibTeX
@article{Johnson2026,
  author = {Johnson, Grace J and Goulding, Alison N and Denning, Stacie G and Clark, Steven L},
  title = {The Equivalence of Fetal Heart Rate Variability and Accelerations in the Interpretation of Non-Stress Tests},
  journal = {American Journal of Perinatology},
  year = {2026},
  volume = {43},
  number = {12},
  pages = {1673--1677},
  doi = {10.1055/a-2814-9328}
}