PatchCTG: A Patch Cardiotocography Transformer for Antepartum Fetal Health Monitoring

M Jaleed Khan iD, Manu Vatish iD, Gabriel Davis Jones iD

Sensors · 2025

DOI: 10.3390/s25092650 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von M Jaleed Khan und 2 weiteren Autor:innen. Beteiligte Einrichtung: Oxford Digital Health Labs, Nuffield Department of Women's & Reproductive Health (NDWRH), University of Oxford, Women's Centre (Level 3), John Radcli…. Hauptthemen laut MEDLINE: Cardiotocography, Fetal Monitoring. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: UK Research and Innovation, Medical Research Council, The Alan Turing Institute’s Enrichment Scheme.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Antepartum Cardiotocography (CTG) is a biomedical sensing technology widely used for fetal health monitoring. While the visual interpretation of CTG traces is highly subjective, with the inter-observer agreement as low as 29% and a false positive rate of approximately 60%, the Dawes–Redman system provides an automated approach to fetal well-being assessments. However, it is primarily designed to rule out adverse outcomes rather than detect them, resulting in a high specificity (90.7%) but low sensitivity (18.2%) in identifying fetal distress. This paper introduces PatchCTG, an AI-enabled biomedical time series transformer for CTG analysis. It employs patch-based tokenisation, instance normalisation, and channel-independent processing to capture essential local and global temporal dependencies within CTG signals. PatchCTG was evaluated on the Oxford Maternity (OXMAT) dataset, which comprises over 20,000 high-quality CTG traces from diverse clinical outcomes, after applying the inclusion and exclusion criteria. With extensive hyperparameter optimisation, PatchCTG achieved an AUC of 0.77, with a specificity of 88% and sensitivity of 57% at Youden’s index threshold, demonstrating its adaptability to various clinical needs. Its robust performance across varying temporal thresholds highlights its potential for both real-time and retrospective analysis in sensor-driven fetal monitoring. Testing across varying temporal thresholds showcased it robust predictive performance, particularly with finetuning on data closer to delivery, achieving a sensitivity of 52% and specificity of 88% for near-delivery cases. These findings suggest the potential of PatchCTG to enhance clinical decision-making in antepartum care by providing a sensor-based, AI-driven, objective tool for reliable fetal health assessment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CardiotocographyFetal MonitoringHumansPregnancyFemaleHeart Rate, FetalSignal Processing, Computer-Assisted

Stichwörter der Autor:innen

antepartumbiomedical time seriescardiotocographyfetal healthtransformer

Autor:innen und Institutionen

  • Oxford Digital Health Labs, Nuffield Department of Women's & Reproductive Health (NDWRH), University of Oxford, Women's Centre (Level 3), John Radcliffe Hospital, Oxford OX3 9DU, UK.

ORCID-Profile: M Jaleed Khan, Manu Vatish, Gabriel Davis Jones

Förderung

  • UK Research and Innovation
  • Medical Research Council
  • The Alan Turing Institute’s Enrichment Scheme

Zitieren

APA

Khan, M. J., Vatish, M., & Davis Jones, G. (2025). PatchCTG: A Patch Cardiotocography Transformer for Antepartum Fetal Health Monitoring. Sensors. https://doi.org/10.3390/s25092650

Vancouver

Khan MJ, Vatish M, Davis Jones G. PatchCTG: A Patch Cardiotocography Transformer for Antepartum Fetal Health Monitoring. Sensors. 2025. doi:10.3390/s25092650

BibTeX
@article{Khan2025,
  author = {Khan, M Jaleed and Vatish, Manu and Davis Jones, Gabriel},
  title = {PatchCTG: A Patch Cardiotocography Transformer for Antepartum Fetal Health Monitoring},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25092650}
}
Kostenlos starten →