Endoloop-assisted endoscopic removal of over-the-scope and full-thickness resection device clips: a prospective study
Endoscopy International Open · 06.03.2026 · 14 (CP)
DOI: 10.1055/a-2784-8740 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopy International Open, erschienen am 06.03.2026. Verfasst von Tobias Blasberg und 9 weiteren Autor:innen. Beteiligte Einrichtung: Gastroenterology, Gastrointestinal Oncology and Interventional Endoscopy, Sana Klinikum Offenbach GmbH, Offenbach, Germany. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background and study aims: The over-the-scope (OTS) clip system is an established tool for endoscopic management of gastrointestinal bleeding, perforations, fistulas, and, in its modified form as the full-thickness resection device (FTRD), for resection of gastrointestinal lesions. In selected cases, clip removal is required. Conventional techniques often demand costly devices and may be time-consuming. This study evaluated a novel, simple technique for endoscopic removal of OTS and FTRD clips using an endoloop, focusing on feasibility and safety. Patients and methods: This prospective single-center study included patients who had undergone OTS or FTRD clip placement and required clip removal between March 2021 and October 2024. The removal procedure involved positioning an endoloop underneath the clip. Follow-up endoscopy within six months assessed clip detachment. The primary endpoint was the success rate of clip removal; the secondary endpoint was the incidence of adverse events.
Results
A total of 18 patients underwent endoloop-assisted removal of OTS (50%, 9/18) or FTRD (50%, 9/18) clips. Endoloop placement was performed at a median of 94 days (range: 27 – 472) after OTS clip placement and 97 days (range: 0 – 274) after EFTR. Follow-up endoscopy confirmed clip detachment after a median of 107 days (range: 33 – 220) for OTS and 114 days (range: 5 – 203) for FTRD clips. Clip removal was successful in all patients (100%), with no adverse event observed.
Conclusion
Endoloop-assisted removal of OTS and FTRD clips appears to be effective and safe, representing an addition to current options for endoscopic clip removal.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Gastroenterology, Gastrointestinal Oncology and Interventional Endoscopy, Sana Klinikum Offenbach GmbH, Offenbach, Germany.
- Department of Hepatology and Gastroenterology, Charité - Universitätsmedizin Berlin Campus Charite Mitte, Berlin, Germany.
- Clinic for Gastroenterology, Gastrointestinal Oncology and Endocrinology, University Medical Center Göttingen, Göttingen, Germany.
- Department of Medicine I Gastroenterology Hepatology Pneumology Allergology Endocrinology Diabetology, Medical Clinic 1, University Hospital Frankfurt, Frankfurt, Germany.
- Department of Clinical and Interventional Radiology, University Medical Center Göttingen, Göttingen, Germany.
Zitieren
APA
Blasberg, T., Hiebel, L., Meiborg, M., Richl, J., Michael, F. A., Seif Amir Hosseini, A., Amanzada, A., Ellenrieder, V., Hochberger, J., & Edris, W. (2026). Endoloop-assisted endoscopic removal of over-the-scope and full-thickness resection device clips: a prospective study. Endoscopy International Open, 14(CP). https://doi.org/10.1055/a-2784-8740
Vancouver
Blasberg T, Hiebel L, Meiborg M, Richl J, Michael FA, Seif Amir Hosseini A, et al. Endoloop-assisted endoscopic removal of over-the-scope and full-thickness resection device clips: a prospective study. Endoscopy International Open. 2026;14(CP). doi:10.1055/a-2784-8740
BibTeX
@article{Blasberg2026,
author = {Blasberg, Tobias and Hiebel, Lukas and Meiborg, Moritz and Richl, Johannes and Michael, Florian Alexander and Seif Amir Hosseini, Ali and Amanzada, Ahmad and Ellenrieder, Volker and Hochberger, Juergen and Edris, Wedi},
title = {Endoloop-assisted endoscopic removal of over-the-scope and full-thickness resection device clips: a prospective study},
journal = {Endoscopy International Open},
year = {2026},
volume = {14},
number = {CP},
doi = {10.1055/a-2784-8740}
}