Over-the-scope pre-looping method using an endoloop in endoscopic full-thickness resection of gastric gastrointestinal stromal tumor

Reona Kawamura, Seiichiro Abe iD, Yasuhiko Mizuguchi, Satoru Nonaka, Yutaka Saito

Endoscopy · 01.12.2024 · 56 (S 01 S 01) · E1034-E1035

DOI: 10.1055/a-2462-1333 ↗

Kurz gefasst

Klinische Studie in der Zeitschrift Endoscopy, erschienen am 01.12.2024. Verfasst von Reona Kawamura und 4 weiteren Autor:innen. Beteiligte Einrichtung: Endoscopy Division, National Cancer Center Hospital, Chuo-ku, Tokyo, Japan. Die Arbeit nennt 2 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Endoscopic full-thickness resection (EFTR) for small gastric gastrointestinal stromal tumors (GISTs) is a feasible and effective procedure [ 1 ]. However, visual field obstruction during defect approximation post-EFTR often poses a challenge due to inadequate gastric distension [ 2 ]. To address this, we developed a method where an endoloop is maneuvered over the scope to the circumferential incision, forming a “pre-loop” that allows for rapid approximation of the full-thickness defect after EFTR. A 72-year-old man presented with a submucosal tumor measuring 25 mm in diameter, suspected to be a GIST located on the anterior wall of the middle gastric body ([ Fig. 1 ]). The EFTR was performed in an operating room setting ([ Video 1 ]). To minimize the size of the full-thickness defect, submucosal dissection was initially performed around the lesion ([ Fig. 2 ]). After identifying the lesion’s capsule, an endoloop was advanced while grasping the scope tip and positioned over the scope ([ Fig. 3 ]). The loop was then opened at the mucosal incision site and anchored with endoclips, a technique we term “pre-looping” ([ Fig. 4 ]). Fig. 1 A 25-mm submucosal tumor located on the anterior wall of the middle part of the gastric body. Fig. 2 Submucosal dissection was performed to reduce the full-thickness defect area. Fig. 3 An endoloop was used to grasp the tip of the scope and placed over the scope. Fig. 4 The endoloop was anchored using endoclips, a technique we term the “pre-looping” method. Quality: mobile 360 480 720 Download Endoscopic full-thickness resection (EFTR) was performed in the operating room for a gastric gastrointestinal stromal tumor (GIST) in a 72-year-old man. An over-the-scope pre-looping suture method using an endoloop was performed after EFTR.Video 1 The procedure took 10 min, with endoloop approximation completed post-EFTR. Approximation of the full-thickness defect required an additional 3 min, followed by closure of a residual mucosal defect using a second endoloop ([ Fig. 5 ]). The total approximation time was 21 min. Fig. 5 Complete approximation of the defect area following tumor excision. The patient experienced no intraoperative or postoperative complications and was discharged on the fifth postoperative day. Pathological analysis confirmed a low-risk GIST with negative horizontal and vertical margins. This suture technique remains effective even in cases where gastric lumen collapse follows EFTR, making it a quick and reliable method for defect closure. We intend to adopt this technique as a standard for EFTR in our hospital. Endoscopy_UCTN_Code_TTT_1AO_2AG_3AF Endoscopy E-Videos https://eref.thieme.de/e-videos E-Videos is an open access online section of the journal Endoscopy , reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high-quality video and are published with a Creative Commons CC-BY license. Endoscopy E-Videos qualify for HINARI discounts and waivers and eligibility is automatically checked during the submission process. We grant 100% waivers to articles whose corresponding authors are based in Group A countries and 50% waivers to those who are based in Group B countries as classified by Research4Life (see: https://www.research4life.org/access/eligibility/ ). This section has its own submission website at https://mc.manuscriptcentral.com/e-videos . Publication History Article published online: 26 November 2024 © 2024. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany

Autor:innen und Institutionen

  • Endoscopy Division, National Cancer Center Hospital, Chuo-ku, Tokyo, Japan.

ORCID-Profile: Seiichiro Abe

Zitieren

APA

Kawamura, R., Abe, S., Mizuguchi, Y., Nonaka, S., & Saito, Y. (2024). Over-the-scope pre-looping method using an endoloop in endoscopic full-thickness resection of gastric gastrointestinal stromal tumor. Endoscopy, 56(S 01 S 01), E1034-E1035. https://doi.org/10.1055/a-2462-1333

Vancouver

Kawamura R, Abe S, Mizuguchi Y, Nonaka S, Saito Y. Over-the-scope pre-looping method using an endoloop in endoscopic full-thickness resection of gastric gastrointestinal stromal tumor. Endoscopy. 2024;56(S 01 S 01):E1034-E1035. doi:10.1055/a-2462-1333

BibTeX
@article{Kawamura2024,
  author = {Kawamura, Reona and Abe, Seiichiro and Mizuguchi, Yasuhiko and Nonaka, Satoru and Saito, Yutaka},
  title = {Over-the-scope pre-looping method using an endoloop in endoscopic full-thickness resection of gastric gastrointestinal stromal tumor},
  journal = {Endoscopy},
  year = {2024},
  volume = {56},
  number = {S 01 S 01},
  pages = {E1034--E1035},
  doi = {10.1055/a-2462-1333}
}
Kostenlos starten →