EUVIMEDEUVIMED entdecken
Crossref

Clinical Outcomes after Implantation of the Toric Tecnis Eyhance Intraocular Lens: a Retrospective Analysis

Rafael Lucena iD, Christoph Tappeiner iD, Marco Langenegger, David Goldblum iD, Tamer Tandogan

Klinische Monatsblätter für Augenheilkunde · 01.04.2026 · 243 (04) · 330-334

DOI: 10.1055/a-2778-8543 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Klinische Monatsblätter für Augenheilkunde, erschienen am 01.04.2026. Verfasst von Rafael Lucena und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Pallas Kliniken AG, Olten, Switzerland. Hauptthemen laut MEDLINE: Lenses, Intraocular, Lens Implantation, Intraocular, Astigmatism, Patient Satisfaction. Die Arbeit nennt 16 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The Tecnis Eyhance Toric intraocular lens (IOL) model DIU00 (Johnson & Johnson) is a monofocal IOL with a slightly enhanced depth of focus, designed to improve intermediate vision while correcting corneal astigmatism in cataract surgery. While its optical concept has been validated in clinical trials, evidence from routine practice is still limited. The purpose of this study was to evaluate real-world visual and refractive outcomes, postoperative astigmatism, and patient satisfaction following implantation of the Eyhance Toric IOL.

Methods

A total of 160 eyes from 97 consecutive patients were analysed, including 63 patients who underwent a bilateral procedure and 34 who had unilateral surgery with Eyhance Toric implantation. Preoperative biometry comprised axial length, anterior chamber depth, lens thickness, sulcus-to-sulcus distance, and keratometry values. At 1 month, monocular and binocular visual acuities (uncorrected [UDVA], corrected [CDVA], uncorrected intermediate [UIVA], distance-corrected intermediate [DCIVA], uncorrected near [UNVA], distance-corrected near [DCNVA]), manifest refraction, and keratometry were evaluated.

Results

At 1 month, mean monocular UDVA, CDVA, UIVA, DCIVA, and UNVA were 0.12, 0.05, 0.06, 0.07, and 0.29 logMAR, respectively. Binocular UDVA, UIVA, and UNVA were 0.04, 0.03, and 0.24 logMAR, respectively. Mean corneal astigmatism decreased from − 1.70 ± 0.91 D to a postoperative refractive astigmatism of 0.31 ± 0.24 D (p < 0.0001). No IOL rotations were required. Spectacle independence was achieved in 13 patients (20.64%), while 50 (79.36%) required reading glasses. Among those targeted for bilateral emmetropia, 35 (87.5%) of 40 needed reading spectacles, compared with 15 (65%) of 23 patients with a mini-monovision refractive targe (p = 0.048). No disturbing dysphotopsias such as halos or glare were reported.

Conclusion

The Tecnis Eyhance Toric IOL demonstrated favourable outcomes for distance and intermediate vision, reliable astigmatism correction, and high patient satisfaction.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lenses, IntraocularLens Implantation, IntraocularAstigmatismPatient SatisfactionPostoperative ComplicationsHumansRetrospective StudiesTreatment OutcomeFemaleMaleAgedVisual AcuityMiddle AgedProsthesis DesignAged, 80 and overRefraction, Ocular

Autor:innen und Institutionen

  • Department of Ophthalmology, Pallas Kliniken AG, Olten, Switzerland.
  • Department of Ophthalmology, University Hospital Essen, University Duisburg-Essen, Essen, Germany.
  • Medical Faculty, University of Bern, Bern, Switzerland.
  • Medical Faculty, University of Basel, Basel, Switzerland.
  • Department of Ophthalmology, University Hospital, Heidelberg, Germany.

ORCID-Profile: Rafael Lucena, Christoph Tappeiner, David Goldblum

Zitieren

APA

Lucena, R., Tappeiner, C., Langenegger, M., Goldblum, D., & Tandogan, T. (2026). Clinical Outcomes after Implantation of the Toric Tecnis Eyhance Intraocular Lens: a Retrospective Analysis. Klinische Monatsblätter für Augenheilkunde, 243(04), 330-334. https://doi.org/10.1055/a-2778-8543

Vancouver

Lucena R, Tappeiner C, Langenegger M, Goldblum D, Tandogan T. Clinical Outcomes after Implantation of the Toric Tecnis Eyhance Intraocular Lens: a Retrospective Analysis. Klinische Monatsblätter für Augenheilkunde. 2026;243(04):330-334. doi:10.1055/a-2778-8543

BibTeX
@article{Lucena2026,
  author = {Lucena, Rafael and Tappeiner, Christoph and Langenegger, Marco and Goldblum, David and Tandogan, Tamer},
  title = {Clinical Outcomes after Implantation of the Toric Tecnis Eyhance Intraocular Lens: a Retrospective Analysis},
  journal = {Klinische Monatsblätter für Augenheilkunde},
  year = {2026},
  volume = {243},
  number = {04},
  pages = {330--334},
  doi = {10.1055/a-2778-8543}
}
Kostenlos starten →