EUVIMEDEUVIMED entdecken
Crossref

Assessment of the refractive outcomes of patients with regular corneal astigmatism implanted with high-power toric intraocular lenses

Yannis Badri, Antoine Levron, Emilie Agard, Charles-Henry Remignon, Roman Chudzinski, Jeremy Billant, Hugo Bouvarel, Pierre Leroux, Ines Fenniri, Pierre Pradat, Corinne Dot

Graefe's Archive for Clinical and Experimental Ophthalmology · 2024

DOI: 10.1007/s00417-024-06586-8 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Graefe's Archive for Clinical and Experimental Ophthalmology, 2024. Verfasst von Yannis Badri und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Edouard Herriot University Hospital, 69003, Lyon, France. yannis.badri@gmail.com. Hauptthemen laut MEDLINE: Astigmatism, Visual Acuity, Refraction, Ocular, Lenses, Intraocular. Die Arbeit nennt 27 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: To describe the refractive outcomes of eyes with high regular corneal astigmatism undergoing age-related cataract surgery. METHODS: Astigmatic patients who underwent cataract surgery with implantation of high-power XY1AT HOYA® toric lenses (IOLs) (≥ T5) between March 2020 and June 2022 were included. Patients were divided into 2 groups based on the type of Total Corneal Astigmatism (TCA) used for the toric IOL calculation: group 1 = TCATK- 700 (TCA measured by the Iol Master 700®) and group 2 = TCAAK- 700 (TCA estimated from the anterior keratometry of the Iol Master 700® and using the Abulafia-Koch regression). The best-uncorrected (UDVA) and corrected (CDVA) distance visual acuity, subjective spherical equivalent (SSEq) and subjective residual cylinder (SRC) were assessed at 1 month. The predictability (centroid [CEPA] and mean absolute error in predicted astigmatism [MAEPA]) of the 2 TCA assessment methods was analyzed. RESULTS: 96 eyes of 74 patients were included. In the whole cohort, the UDVA was 0.14 ± 0.19 logMAR, the CDVA was 0.04 ± 0.07 logMAR. Postoperative SSEq was - 0.24 ± 0.53D. Postoperative SRC was - 0.48 ± 0.56D. The UDVA, SSEq and SRC did not significantly differ between groups. The MAEPA was significantly better with TCAAK-700 compared to TCATK-700: 0.58 ± 0.52D versus 0.65 ± 0.55D (p = 0.01). No significant difference was observed for the CEPA (p(x) = 0.09, p(y) = 0.19). CONCLUSIONS: XY1AT HOYA® toric IOLs are a very good alternative even in case of high toricity. Residual astigmatism predictability is high, it would be better with TCAAK- 700. This data should be confirmed with a larger sample of patients.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AstigmatismVisual AcuityRefraction, OcularLenses, IntraocularProsthesis DesignHumansMaleFemaleAgedRetrospective StudiesCorneaCorneal TopographyMiddle AgedFollow-Up StudiesLens Implantation, IntraocularPseudophakiaPhacoemulsificationTreatment OutcomeAged, 80 and over

Stichwörter der Autor:innen

AstigmatismCataractKeratometryLens

Autor:innen und Institutionen

  • Department of Ophthalmology, Edouard Herriot University Hospital, 69003, Lyon, France. yannis.badri@gmail.com.
  • Ophtalmology Department, HIA Desgenettes, Lyon, France.
  • Department of Ophthalmology, Edouard Herriot University Hospital, 69003, Lyon, France.
  • French Military Health Service Academy, Val de Grâce, Paris, France.

Zitieren

APA

Badri, Y., Levron, A., Agard, E., Remignon, C. H., Chudzinski, R., Billant, J., Bouvarel, H., Leroux, P., Fenniri, I., Pradat, P., & Dot, C. (2024). Assessment of the refractive outcomes of patients with regular corneal astigmatism implanted with high-power toric intraocular lenses. Graefe's Archive for Clinical and Experimental Ophthalmology. https://doi.org/10.1007/s00417-024-06586-8

Vancouver

Badri Y, Levron A, Agard E, Remignon CH, Chudzinski R, Billant J, et al. Assessment of the refractive outcomes of patients with regular corneal astigmatism implanted with high-power toric intraocular lenses. Graefe's Archive for Clinical and Experimental Ophthalmology. 2024. doi:10.1007/s00417-024-06586-8

BibTeX
@article{Badri2024,
  author = {Badri, Yannis and Levron, Antoine and Agard, Emilie and Remignon, Charles-Henry and Chudzinski, Roman and Billant, Jeremy and Bouvarel, Hugo and Leroux, Pierre and Fenniri, Ines and Pradat, Pierre and Dot, Corinne},
  title = {Assessment of the refractive outcomes of patients with regular corneal astigmatism implanted with high-power toric intraocular lenses},
  journal = {Graefe's Archive for Clinical and Experimental Ophthalmology},
  year = {2024},
  doi = {10.1007/s00417-024-06586-8}
}
Kostenlos starten →