EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Opportunities to reduce the environmental impact of endoscopy: a detailed material flow analysis of diagnostic colonoscopy

Ceyda B Izci iD, Maria Sofia Clercx Lao, Britta Vegting iD, Peter D Siersema, Maike V Tietschert, Nicole G M Hunfield, Jan-Carel Diehl, Pieter Jan F de Jonge

Endoscopy · 01.06.2026 · 58 (06) · 618-626

DOI: 10.1055/a-2773-5144 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.06.2026. Verfasst von Ceyda B Izci und 7 weiteren Autor:innen. Beteiligte Einrichtung: Erasmus MC University Medical Center Rotterdam, Gastroenterology and Hepatology, Netherlands, Rotterdam. Hauptthemen laut MEDLINE: Colonoscopy, Carbon Footprint. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 11 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Erasmus MC Convergence Sustainable Health Program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Gastrointestinal endoscopy is the third largest contributor to hospitals’ environmental footprints. Colonoscopies, among the most frequently performed endoscopic procedures, are considered to have a significant environmental footprint, yet their exact impact is unknown. We analyzed the material flow of diagnostic colonoscopy to identify opportunities for reducing its environmental impact. A single-center material flow analysis (MFA) was conducted during a week with diagnostic colonoscopy procedures. Waste was collected, weighed, and categorized by product type. The material composition was identified. Using visual mapping, we identified which products were used and discarded at each stage of the procedure. 15 diagnostic colonoscopy procedures were audited. Mean (SD) waste mass per procedure was 0.58 (0.01) kg, including an average of 46 products. Extrapolated to the hospital’s annual diagnostic colonoscopies, this equals approximately 1169 kg of waste. Plastic-based products constituted the largest product category (22.7%). Nitrile made up the largest material category (14.1% of the total weight of materials). The estimated carbon footprint for the analyzed waste was 1.77 kg CO2e, with nitrile and polypropylene being the largest contributors. Most products were used and discarded in the preparation stage of the colonoscopy procedure. Plastic-based materials were the largest contributor to the total used product weight. These findings inform decision-makers in designing targeted interventions to reduce the environmental impact of diagnostic colonoscopy, for example by considering more sustainable materials such as fiber-based materials. The prepared visual map makes waste generation discussable among healthcare professionals, thereby supporting a collaborative approach to identify opportunities to improve sustainability.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ColonoscopyCarbon FootprintHumansPlastics

Substanzen

Plastics

Autor:innen und Institutionen

  • Erasmus MC University Medical Center Rotterdam, Gastroenterology and Hepatology, Netherlands, Rotterdam.
  • Delft University of Technology, Design for Sustainability, Netherlands, Delft.
  • Erasmus Universiteit Rotterdam Erasmus School of Health Policy and Management, Socio-Medical Sciences, Netherlands, Rotterdam.
  • Erasmus MC University Medical Center Rotterdam, Adult Intensive Care, Netherlands, Rotterdam.
  • Erasmus MC University Medical Center Rotterdam, Hospital Pharmacy, Netherlands, Rotterdam.

ORCID-Profile: Ceyda B Izci, Britta Vegting

Förderung

  • Erasmus MC Convergence Sustainable Health Program

Zitieren

APA

Izci, C. B., Clercx Lao, M. S., Vegting, B., Siersema, P. D., Tietschert, M. V., Hunfield, N. G. M., Diehl, J. C., & de Jonge, P. J. F. (2026). Opportunities to reduce the environmental impact of endoscopy: a detailed material flow analysis of diagnostic colonoscopy. Endoscopy, 58(06), 618-626. https://doi.org/10.1055/a-2773-5144

Vancouver

Izci CB, Clercx Lao MS, Vegting B, Siersema PD, Tietschert MV, Hunfield NGM, et al. Opportunities to reduce the environmental impact of endoscopy: a detailed material flow analysis of diagnostic colonoscopy. Endoscopy. 2026;58(06):618-626. doi:10.1055/a-2773-5144

BibTeX
@article{Izci2026,
  author = {Izci, Ceyda B and Clercx Lao, Maria Sofia and Vegting, Britta and Siersema, Peter D and Tietschert, Maike V and Hunfield, Nicole G M and Diehl, Jan-Carel and de Jonge, Pieter Jan F},
  title = {Opportunities to reduce the environmental impact of endoscopy: a detailed material flow analysis of diagnostic colonoscopy},
  journal = {Endoscopy},
  year = {2026},
  volume = {58},
  number = {06},
  pages = {618--626},
  doi = {10.1055/a-2773-5144}
}
Kostenlos starten →