EUVIMEDEUVIMED entdecken
Klinische StudieOpen Access · CC BY 4.0

Environmental impact of computer-aided diagnosis in colonoscopy: a carbon footprint assessment of a prospective study cohort

Olaolu Olabintan iD, Natalie Halvorsen, Robin Baddeley, Shin-Ei Kudo, Ishita Barua iD, Masashi Misawa iD, Kensaku Mori, Claire Hunt, Jens Aksel Nilsen, Svein Oskar Frigstad, James E East, Amit Rastogi und 9 weitere

Endoscopy · 01.03.2026 · 58 (03) · 303-309

DOI: 10.1055/a-2717-8365 ↗

Kurz gefasst

Klinische Studie in der Zeitschrift Endoscopy, erschienen am 01.03.2026. Verfasst von Olaolu Olabintan und 20 weiteren Autor:innen. Beteiligte Einrichtung: King's Institute of Theraputic Endoscopy, King's College Hospital NHS Foundation Trust, London, United Kingdom of Great Britain and Northern Ireland. Hauptthemen laut MEDLINE: Colonoscopy, Diagnosis, Computer-Assisted, Carbon Footprint, Colonic Polyps. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Commission, Japan Society of Promotion of Science, National Institute for Health Research (NIHR) Oxford Biomedical Research Centre.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The environmental impact of computer-aided diagnosis (CADx) in colonoscopy is unknown. The potential to reduce greenhouse gas emissions by limiting unnecessary polypectomies may be offset by emissions associated with CADx devices. We quantified and compared the carbon footprint of colonoscopy with and without CADx. Life-cycle carbon emissions associated with endoscopic snares, polyp traps, histopathology, and CADx devices were estimated using life-cycle assessment software. The effect of CADx was estimated by the carbon dioxide equivalent (CO2e) emissions related to outcomes from a prospective cohort of patients who underwent colonoscopy with optical diagnosis under a leave-in-situ strategy (i.e. rectosigmoid polyps ≤5 mm predicted as non-neoplastic were not removed) with and without CADx assistance. We analyzed 1134 individuals (median age 67 years, 59% male) with 1716 colorectal polyps. Colonoscopy with CADx reduced the number of snares and polyp traps from 567 to 543 (difference: 24) and histopathology submissions from 1343 to 1278 (difference: 65). However, the total carbon footprint increased from 832 kg CO2e (95%CI 815 to 847) without CADx to 946 kg CO2e (95%CI 927 to 965) with CADx, corresponding to an absolute increase of 114 kg CO2e (95%CI 80 to 150) or 0.10 kg CO2e per colonoscopy. Using CADx under a leave-in-situ strategy increased the environmental burden of colonoscopy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ColonoscopyDiagnosis, Computer-AssistedCarbon FootprintColonic PolypsHumansMaleFemaleAgedProspective StudiesMiddle Aged

Autor:innen und Institutionen

  • King's Institute of Theraputic Endoscopy, King's College Hospital NHS Foundation Trust, London, United Kingdom of Great Britain and Northern Ireland.
  • Faculty of Life Sciences and Medicine, King's College London, London, United Kingdom of Great Britain and Northern Ireland.
  • Clinical Effectiveness Research Group, University of Oslo, Oslo, Norway.
  • Clinical Effectiveness Research Group, Oslo University Hospital, Oslo, Norway.
  • Wolfson Unit for Endoscopy, St Mark's Hospital and Academic Institute, London, United Kingdom of Great Britain and Northern Ireland.
  • King's Institute of Therapeutic Endoscopy, King's College Hospital NHS Foundation Trust, London, United Kingdom of Great Britain and Northern Ireland.

ORCID-Profile: Olaolu Olabintan, Ishita Barua, Masashi Misawa, Cesare Hassan, Bu Hayee, Yuichi Mori

Förderung

  • European Commission
  • Japan Society of Promotion of Science
  • National Institute for Health Research (NIHR) Oxford Biomedical Research Centre

Zitieren

APA

Olabintan, O., Halvorsen, N., Baddeley, R., Kudo, S. E., Barua, I., Misawa, M., Mori, K., Hunt, C., Nilsen, J. A., Frigstad, S. O., East, J. E., Rastogi, A., Hassan, C., Kalager, M., Løberg, M., Haji, A., Holme, Ø., Bretthauer, M., Hayee, B., …, & Gulati, S. (2026). Environmental impact of computer-aided diagnosis in colonoscopy: a carbon footprint assessment of a prospective study cohort. Endoscopy, 58(03), 303-309. https://doi.org/10.1055/a-2717-8365

Vancouver

Olabintan O, Halvorsen N, Baddeley R, Kudo SE, Barua I, Misawa M, et al. Environmental impact of computer-aided diagnosis in colonoscopy: a carbon footprint assessment of a prospective study cohort. Endoscopy. 2026;58(03):303-309. doi:10.1055/a-2717-8365

BibTeX
@article{Olabintan2026,
  author = {Olabintan, Olaolu and Halvorsen, Natalie and Baddeley, Robin and Kudo, Shin-Ei and Barua, Ishita and Misawa, Masashi and Mori, Kensaku and Hunt, Claire and Nilsen, Jens Aksel and Frigstad, Svein Oskar and East, James E and Rastogi, Amit and Hassan, Cesare and Kalager, Mette and Løberg, Magnus and Haji, Amyn and Holme, Øyvind and Bretthauer, Michael and Hayee, Bu and Mori, Yuichi and Gulati, Shraddha},
  title = {Environmental impact of computer-aided diagnosis in colonoscopy: a carbon footprint assessment of a prospective study cohort},
  journal = {Endoscopy},
  year = {2026},
  volume = {58},
  number = {03},
  pages = {303--309},
  doi = {10.1055/a-2717-8365}
}
Kostenlos starten →