EUVIMEDEUVIMED entdecken
Crossref

Mechanical Evaluation of an Orthogonal Angle-Stable Interlocking Nail in a Comminuted Fracture Model

Dayvid V F Lucena, Bruno W Minto iD, Thiago A S S Rocha, Caio A S Malta, Alefe L C Carrera iD, Danyelle R C Ferreira, Júlian A S Galíndez iD, Luis G G G Dias

Veterinary and Comparative Orthopaedics and Traumatology · 01.07.2026 · 39 (04) · 223-228

DOI: 10.1055/a-2737-6788 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Veterinary and Comparative Orthopaedics and Traumatology, erschienen am 01.07.2026. Verfasst von Dayvid V F Lucena und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Veterinary Medicine, Federal University of Jataí, Jataí, Goias, Brazil. Hauptthemen laut MEDLINE: Bone Nails, Fractures, Comminuted, Fracture Fixation, Intramedullary. Die Arbeit nennt 34 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study aimed to describe an orthogonal angle-stable (ASO) intramedullary nail, evaluate its mechanical properties, and compare its performance with a conventional and an angle-stable nails. Synthetic diaphyseal models with a 25-mm gap fracture were 3D printed using polylactic acid. The ASO nail, fabricated from 316 L stainless steel, featured two orthogonal distal holes spaced 5.5-mm apart. Mechanical properties were evaluated through axial compression and torsion tests until failure. The stiffness and yield load under axial compression and peak torque under torsion were used to compare the ASO nail (ASO group) with a conventional interlocking (IC group) and a uniplanar angle-stable (ASU group) nails. Seven tests per group were performed and analysed using Kruskal–Wallis and Dunn's post hoc tests. The ASO and ASU nails exhibited similar stiffness under axial loading and demonstrated greater stiffness than the IC nails. No differences were observed among the groups regarding yield load or peak torque under torsion. The ASO nail exhibited biomechanical properties similar to the ASU nail and both demonstrated superiority over the IC. Further studies focusing on implant development and refinement of the implantation technique are necessary before clinical application can be considered.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Bone NailsFractures, ComminutedFracture Fixation, IntramedullaryAnimalsBiomechanical PhenomenaMaterials Testing

Autor:innen und Institutionen

  • Department of Veterinary Medicine, Federal University of Jataí, Jataí, Goias, Brazil.
  • Department of Veterinary Clinics and Surgery, School of Agricultural and Veterinary Studies, São Paulo State University, Jaboticabal, São Paulo, Brazil.

ORCID-Profile: Bruno W Minto, Alefe L C Carrera, Júlian A S Galíndez

Zitieren

APA

Lucena, D. V. F., Minto, B. W., Rocha, T. A. S. S., Malta, C. A. S., Carrera, A. L. C., Ferreira, D. R. C., Galíndez, J. A. S., & Dias, L. G. G. G. (2026). Mechanical Evaluation of an Orthogonal Angle-Stable Interlocking Nail in a Comminuted Fracture Model. Veterinary and Comparative Orthopaedics and Traumatology, 39(04), 223-228. https://doi.org/10.1055/a-2737-6788

Vancouver

Lucena DVF, Minto BW, Rocha TASS, Malta CAS, Carrera ALC, Ferreira DRC, et al. Mechanical Evaluation of an Orthogonal Angle-Stable Interlocking Nail in a Comminuted Fracture Model. Veterinary and Comparative Orthopaedics and Traumatology. 2026;39(04):223-228. doi:10.1055/a-2737-6788

BibTeX
@article{Lucena2026,
  author = {Lucena, Dayvid V F and Minto, Bruno W and Rocha, Thiago A S S and Malta, Caio A S and Carrera, Alefe L C and Ferreira, Danyelle R C and Galíndez, Júlian A S and Dias, Luis G G G},
  title = {Mechanical Evaluation of an Orthogonal Angle-Stable Interlocking Nail in a Comminuted Fracture Model},
  journal = {Veterinary and Comparative Orthopaedics and Traumatology},
  year = {2026},
  volume = {39},
  number = {04},
  pages = {223--228},
  doi = {10.1055/a-2737-6788}
}
Kostenlos starten →