EUVIMEDEUVIMED entdecken
Crossref

Early and Predictable Restoration of Motion Using a “Kinematic Retaining” Total Knee Replacement: A Prospective Dynamic Fluoroscopic Study

Adrian Harvey iD, Lindsey S Palm-Vlasak iD, Scott A Banks iD, James O Smith iD

The Journal of Knee Surgery · 01.01.2026 · 39 (02) · 071-077

DOI: 10.1055/a-2684-8816 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Knee Surgery, erschienen am 01.01.2026. Verfasst von Adrian Harvey und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics, University Hospitals Dorset NHS Foundation Trust, Royal Bournemouth Hospital, Castle Lane East, Bournemouth, United Kingd…. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Range of Motion, Articular, Knee Prosthesis, Knee Joint. Die Arbeit nennt 33 Literaturangaben. Gefördert von: LimaCorporate, Via Nazionale, 52, Villanova di San Daniele del Friuli, Udine Italy.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

New total knee replacement designs aim to improve patient outcomes through restoration of normal knee joint movements. This study uses in vivo fluoroscopic analysis to quantify the kinematic characteristics of the Physica KR system. Twenty-one patients underwent kinematic fluoroscopic analysis 1 year following implantation of the Physica KR knee using three defined activities (step-up, kneel, and lunge). Assessments were made of initial rollback, maximum flexion, axial rotation, anteroposterior (AP) translation, and the presence or absence of condylar lift-off. A mean maximum passive flexion of 115.8 degrees (standard deviation ± 10.8) was achieved. All joints were congruent throughout range of movement in all three activities. During the step-up activity, the medial femoral condyle exhibited some initial rollback, the lateral condyle moved slightly posteriorly during initial flexion, then back toward its initial alignment with increased flexion. The combined effect produced tibial internal rotation of approximately 5 degrees during the first 90 degrees of flexion with a smooth progression toward slight varus alignment in maximal flexion, with minimal condylar lift-off. During maximal kneeling, both the medial and lateral femoral condyle contact points were just posterior to the AP midline and lift-off of both condyles was noted. During maximal lunge, the medial contact point was slightly anterior to the AP midpoint, with the lateral contact point slightly posterior, resulting in tibial internal rotation. There was no appreciable lift-off of the lateral condyle, although medial condylar lift-off increased from mid-flexion. These in vivo data demonstrate congruent kinematics throughout range of movement, with some initial femoral rollback during early flexion. Our study has shown that the Physica KR knee implant behaved similarly to other established cruciate-retaining implants.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeRange of Motion, ArticularKnee ProsthesisKnee JointOsteoarthritis, KneeHumansFluoroscopyFemaleMaleProspective StudiesAgedMiddle AgedBiomechanical PhenomenaProsthesis DesignAged, 80 and over

Autor:innen und Institutionen

  • Department of Orthopaedics, University Hospitals Dorset NHS Foundation Trust, Royal Bournemouth Hospital, Castle Lane East, Bournemouth, United Kingdom.
  • Department of Mechanical and Aerospace Engineering, University of Florida, Gainesville, Florida, United States.
  • Department of Orthopaedics and Trauma, Dorset County Hospital NHS Foundation Trust, Williams Avenue, Dorchester, Dorset, United Kingdom.

ORCID-Profile: Adrian Harvey, Lindsey S Palm-Vlasak, Scott A Banks, James O Smith

Förderung

  • LimaCorporate, Via Nazionale, 52, Villanova di San Daniele del Friuli, Udine Italy

Zitieren

APA

Harvey, A., Palm-Vlasak, L. S., Banks, S. A., & Smith, J. O. (2026). Early and Predictable Restoration of Motion Using a “Kinematic Retaining” Total Knee Replacement: A Prospective Dynamic Fluoroscopic Study. The Journal of Knee Surgery, 39(02), 071-077. https://doi.org/10.1055/a-2684-8816

Vancouver

Harvey A, Palm-Vlasak LS, Banks SA, Smith JO. Early and Predictable Restoration of Motion Using a “Kinematic Retaining” Total Knee Replacement: A Prospective Dynamic Fluoroscopic Study. The Journal of Knee Surgery. 2026;39(02):071-077. doi:10.1055/a-2684-8816

BibTeX
@article{Harvey2026,
  author = {Harvey, Adrian and Palm-Vlasak, Lindsey S and Banks, Scott A and Smith, James O},
  title = {Early and Predictable Restoration of Motion Using a “Kinematic Retaining” Total Knee Replacement: A Prospective Dynamic Fluoroscopic Study},
  journal = {The Journal of Knee Surgery},
  year = {2026},
  volume = {39},
  number = {02},
  pages = {071--077},
  doi = {10.1055/a-2684-8816}
}
Kostenlos starten →