Implementation of Passive Deterioration Index Alerts in an Intermediate Care Unit: A Failed Early Warning System Strategy

Thomas F Byrd, Molly Mattson, Mary Polt, Katie Pint, Kiril Dimitrov, Angelica Willis, Julia Lister, Evan Beacom, Chris Tignanelli

Applied Clinical Informatics · 01.08.2025 · 16 (04) · 903-910

DOI: 10.1055/a-2648-4817 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Clinical Informatics, erschienen am 01.08.2025. Verfasst von Thomas F Byrd und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine, Division of Hospital Medicine, University of Minnesota, Minneapolis, Minnesota, United States. Hauptthemen laut MEDLINE: Clinical Deterioration, Intensive Care Units, Early Warning Score, Clinical Alarms. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: AHRQ HHS, The Agency for Healthcare Research and Quality (AHRQ).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Traditional early warning systems (EWS) have shown uncertain efficacy in real-world settings. More recently, machine learning models like the Epic Deterioration Index (DTI) have been developed, promising greater accuracy. Recognizing the potential of DTI, but also the pervasive issue of alert fatigue with interruptive (i.e., pop-up) EWS alerts, our institution implemented a DTI-enabled EWS with passive alerts (colored icons visible in prespecified locations within the electronic health record). We hypothesized that our intervention would reduce the time to treatment for deteriorating patients. We piloted a DTI-enabled EWS in a 30-bed intermediate care unit at a large academic medical center. DTI scores, alert icons, and vital signs appeared on a custom Patient List interface. In the event of an alert, charge nurses were expected to conduct a bedside assessment and escalate care as necessary. We compared the 111-day pre- and postimplementation periods, with alert-to-action time as the primary outcome. Secondary outcomes included mortality, length of stay, ICU transfer, documentation rate, and provider acceptance. Among 301 patients with an elevated-risk score (156 pre- and 145 postimplementation), we found no significant differences in alert-to-action time (469 vs. 359 minutes before alert; p = 0.96), with provider actions typically occurring several hours before the alert in both periods. There were no significant differences in mortality (10.3% vs. 13.1%; p = 0.56), length of stay (15.7 vs. 12.8 days; p = 0.23), or ICU transfer (8.3% vs. 6.2%; p = 0.63). Charge nurses documented acknowledgment of the alert in 18.6% of cases, and acceptance was poor. Most nurses expressed a preference for interruptive alerts and more prominent DTI display locations. In this single-unit pilot, passive DTI-enabled EWS alerts did not improve time to intervention or clinical outcomes. High-risk DTI scores often occurred after clinical deterioration had already been recognized.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Clinical DeteriorationIntensive Care UnitsEarly Warning ScoreClinical AlarmsHumansFemaleVital SignsMale

Autor:innen und Institutionen

  • Department of Medicine, Division of Hospital Medicine, University of Minnesota, Minneapolis, Minnesota, United States.
  • Center for Learning Health System Sciences, University of Minnesota, Minneapolis, Minnesota, United States.
  • Institute for Health Informatics, University of Minnesota, Minneapolis, Minnesota, United States.
  • Fairview Health Services, Minneapolis, Minnesota, United States.
  • Department of Surgery, Division of Acute Care Surgery, University of Minnesota, Minneapolis, Minnesota, United States.

Förderung

  • AHRQ HHS
  • The Agency for Healthcare Research and Quality (AHRQ)

Zitieren

APA

Byrd, T. F., Mattson, M., Polt, M., Pint, K., Dimitrov, K., Willis, A., Lister, J., Beacom, E., & Tignanelli, C. (2025). Implementation of Passive Deterioration Index Alerts in an Intermediate Care Unit: A Failed Early Warning System Strategy. Applied Clinical Informatics, 16(04), 903-910. https://doi.org/10.1055/a-2648-4817

Vancouver

Byrd TF, Mattson M, Polt M, Pint K, Dimitrov K, Willis A, et al. Implementation of Passive Deterioration Index Alerts in an Intermediate Care Unit: A Failed Early Warning System Strategy. Applied Clinical Informatics. 2025;16(04):903-910. doi:10.1055/a-2648-4817

BibTeX
@article{Byrd2025,
  author = {Byrd, Thomas F and Mattson, Molly and Polt, Mary and Pint, Katie and Dimitrov, Kiril and Willis, Angelica and Lister, Julia and Beacom, Evan and Tignanelli, Chris},
  title = {Implementation of Passive Deterioration Index Alerts in an Intermediate Care Unit: A Failed Early Warning System Strategy},
  journal = {Applied Clinical Informatics},
  year = {2025},
  volume = {16},
  number = {04},
  pages = {903--910},
  doi = {10.1055/a-2648-4817}
}
Kostenlos starten →