User-Centered Design in Real-Time: Utilization of an Insider Position to Inform Design and Adoption
Applied Clinical Informatics · 01.05.2025 · 16 (03) · 604-611
DOI: 10.1055/a-2556-4652 ↗Kurz gefasst
Fachartikel in der Zeitschrift Applied Clinical Informatics, erschienen am 01.05.2025. Verfasst von Jessica Kanis und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Emergency Medicine and Pediatrics, Indiana University School of Medicine; Indiana University Heath Inc., Indianapolis, Indiana, United …. Hauptthemen laut MEDLINE: Electronic Health Records, User-Centered Design. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 15 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Electronic health records (EHRs) have significantly impacted healthcare improving access to patient information and enhancing communication among the health care team. However, the lack of usability and increased documentation burden has greatly contributed to clinician burnout. Improvements in EHR design that include physician input are critical to developing specific changes that make EHRs more intuitive and less cumbersome to use; however, it can be challenging to gather input from physicians with full clinical workloads. We sought to establish a practical, repeatable framework for soliciting and integrating user-centered design elements into our vendor EHR system utilizing meaningful clinician involvement and feedback. Over a 1-year period, physician volunteers were given access to a position within the EHR where new features were made available for testing before widespread deployment. Real-time feedback was obtained through a shared platform with institutional IS support leaders and our vendor executive and used to impact design and broader implementation decisions. Physician feedback regarding the testing process was obtained via survey. Thirteen physicians and 15 support staff were given access to a separate unique EHR position to test new EHR features during real-world clinical work at their discretion. Feedback was given via a teams chat function resulting in 1,024 messages from 28 users over a 1-year period peaking in accordance with new features made available. During two primary phases, 8 new EHR features were tested to elicit feedback prior to adoption. Six of the eight features were adopted after initial testing while two required additional changes to improve functionality prior to widespread implementation. The majority found this method intuitive and highly effective in testing new EHR features. Healthcare EHR workflows are effective and well-adopted when informed and designed by clinical users. The insider position was shown to be an effective method for testing new features to gain valuable insight without overburdening clinicians.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Emergency Medicine and Pediatrics, Indiana University School of Medicine; Indiana University Heath Inc., Indianapolis, Indiana, United States.
- Department of Pediatrics, Indiana University School of Medicine, Indiana University Heath Inc., Indianapolis, Indiana, United States.
- Oracle Cerner, Kansas City, Missouri, United States.
- Department of Emergency Medicine, Indiana University School of Medicine; Indiana University Heath Inc., Indianapolis, Indiana, United States.
Zitieren
APA
Kanis, J., Webber, E., Busch, R., & Schaffer, J. (2025). User-Centered Design in Real-Time: Utilization of an Insider Position to Inform Design and Adoption. Applied Clinical Informatics, 16(03), 604-611. https://doi.org/10.1055/a-2556-4652
Vancouver
Kanis J, Webber E, Busch R, Schaffer J. User-Centered Design in Real-Time: Utilization of an Insider Position to Inform Design and Adoption. Applied Clinical Informatics. 2025;16(03):604-611. doi:10.1055/a-2556-4652
BibTeX
@article{Kanis2025,
author = {Kanis, Jessica and Webber, Emily and Busch, Rob and Schaffer, Jason},
title = {User-Centered Design in Real-Time: Utilization of an Insider Position to Inform Design and Adoption},
journal = {Applied Clinical Informatics},
year = {2025},
volume = {16},
number = {03},
pages = {604--611},
doi = {10.1055/a-2556-4652}
}
EUVIMED