EUVIMEDEUVIMED entdecken
Open Access · CC0

A human centered design approach to define and measure documentation quality using an EHR virtual simulation

Ein human-centered-Design-Ansatz zur Definition und Messung der Dokumentationsqualität mithilfe einer EHR-Virtual-Simulation

Megha Kalsy iD, Ryan Burant, Sarah Ball, Anne Pohnert, Mary A Dolansky

PLOS ONE · 19.08.2024 · 19 (8) · e0308992

DOI: 10.1371/journal.pone.0308992 ↗

Auf einen Blick

Mit einem Human-centered-Design-Ansatz wurde eine Methode zur Messung der Dokumentationsqualität in einer EHR-Virtual-Simulation beschrieben. Bei 12 Nurse Practitioners zeigte sich eine variable, teils fehlerhafte und wenig effiziente Dokumentation.

Fragestellung

Wie lässt sich Dokumentationsqualität in elektronischen Gesundheitsakten definieren und mit einer virtuellen Simulation messen?

Methode

Human-centered-Design-Ansatz; virtuelle simulierte Standardpatient:innen-Konsultation über eine EHR-Anbieterplattform; Beobachtung von 12 NPs bei der Dokumentation eines AFHS-4Ms-Besuchs.

Ergebnisse

Dokumentationsqualität wurde als zeitnah, korrekt, nutzerzentriert und effizient definiert. Die Bearbeitungszeiten variierten deutlich; es traten viele fehlerhafte Dokumentationen auf. Die SUS lag meist zwischen 60 und 70, die Klickzahl im Mittel etwa 13 über dem Minimum.

Schlussfolgerung der Autor:innen

Die verwendete HCD-Methodik war durchführbar und lieferte nützliche Informationen zur Qualität der Dokumentation.

Kernaussagen

  • Dokumentationsqualität: zeitnah, korrekt, nutzerzentriert, effizient
  • Bei 12 NPs waren Zeit, Fehler und Klickzahl variabel
  • Die System Usability Scale lag meist zwischen 60 und 70

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Fachartikel in der Zeitschrift PLOS ONE, online erschienen am 19.08.2024. Verfasst von Megha Kalsy und 4 weiteren Autor:innen. Beteiligte Einrichtung: Frances Payne Bolton School of Nursing, Case Western Reserve University, Cleveland, Ohio, United States of America. Hauptthemen laut MEDLINE: Electronic Health Records, Documentation. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC0). Gefördert von: John A. Hartford Foundation.

Auf einen BlickAbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Electronic health record (EHR) documentation serves multiple functions, including recording patient health status, enabling interprofessional communication, supporting billing, and providing data to support the quality infrastructure of a Learning Healthcare System. There is no definition and standardized method to assess documentation quality in EHRs. Using a human-centered design (HCD) approach, we define and describe a method to measure documentation quality. Documentation quality was defined as timely, accurate, user-centered, and efficient. Measurement of quality used a virtual simulated standardized patient visit via an EHR vendor platform. By observing and recording documentation efforts, nurse practitioners (NPs) (N = 12) documented the delivery of an Age-Friendly Health System (AFHS) 4Ms (what Matters, Medication, Mentation, and Mobility) clinic visit using a standardized case. Results for timely documentation indicated considerable variability in completion times of documenting the 4Ms. Accuracy varied, as there were many types of episodes of erroneous documentation and extra time in seconds in documenting the 4Ms. The type and frequency of erroneous documentation efforts were related to navigation burden when navigating to different documentation tabs. The evaluated system demonstrated poor usability, with most participants scoring between 60 and 70 on the System Usability Scale (SUS). Efficiency, measured as click burden (the number of clicks used to navigate through a software system), revealed significant variability in the number of clicks required, with the NPs averaging approximately 13 clicks above the minimum requirement. The HCD methodology used in this study to assess the documentation quality proved feasible and provided valuable information on the quality of documentation. By assessing the quality of documentation, the gathered data can be leveraged to enhance documentation, optimize user experience, and elevate the quality of data within a Learning Healthcare System.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Electronic Health RecordsDocumentationHumansUser-Computer InterfaceNurse PractitionersUser-Centered Design

Autor:innen und Institutionen

  • Frances Payne Bolton School of Nursing, Case Western Reserve University, Cleveland, Ohio, United States of America.
  • Informatics, Decision-Enhancement and Analytic Sciences (IDEAS) Center, George E. Wahlen Veterans Affairs Medical Center, Salt Lake City, Utah, United States of America.
  • Notre Dame College, South Euclid, Ohio, United States of America.
  • MinuteClinic, Woonsocket, Rhode Island, United States of America.
  • Veterans Affairs Northeast Ohio Healthcare System, Cleveland, Ohio, United States of America.

ORCID-Profile: Megha Kalsy

Förderung

  • John A. Hartford Foundation

Zitieren

APA

Kalsy, M., Burant, R., Ball, S., Pohnert, A., & Dolansky, M. A. (2024). A human centered design approach to define and measure documentation quality using an EHR virtual simulation. PLOS ONE, 19(8), e0308992. https://doi.org/10.1371/journal.pone.0308992

Vancouver

Kalsy M, Burant R, Ball S, Pohnert A, Dolansky MA. A human centered design approach to define and measure documentation quality using an EHR virtual simulation. PLOS ONE. 2024;19(8):e0308992. doi:10.1371/journal.pone.0308992

BibTeX
@article{Kalsy2024,
  author = {Kalsy, Megha and Burant, Ryan and Ball, Sarah and Pohnert, Anne and Dolansky, Mary A},
  title = {A human centered design approach to define and measure documentation quality using an EHR virtual simulation},
  journal = {PLOS ONE},
  year = {2024},
  volume = {19},
  number = {8},
  pages = {e0308992},
  doi = {10.1371/journal.pone.0308992}
}
Kostenlos starten →