EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Endoscopic closure using a dedicated device following gastric endoscopic submucosal dissection: Multicenter, prospective, observational pilot study

Kazuo Shiotsuki, Kohei Takizawa iD, Yohei Nose iD, Yuki Kondo, Hitoshi Homma, Taisuke Inada iD, Mao Daikaku, Kosuke Maehara, Shin-Ichiro Fukuda, Hironori Aoki iD, Yorinobu Sumida iD, Hirotada Akiho und 2 weitere

Endoscopy International Open · 13.01.2025 · 13 (CP)

DOI: 10.1055/a-2503-1684 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopy International Open, erschienen am 13.01.2025. Verfasst von Kazuo Shiotsuki und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology, Kitakyushu Municipal Medical Center, Kitakyushu, Japan. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Consortium for Advanced Surgical Endoscopy.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Development of a simple, optimized closure method for mucosal defects left by gastric endoscopic submucosal dissection (ESD) is warranted. Herein, we developed a novel and dedicated closure device called FLEXLOOP and aimed to assess feasibility and safety of the closure using FLEXLOOP following gastric ESD. This multicenter, prospective, observational study enrolled patients clinically diagnosed with gastric neoplasms < 30 mm in size. Following gastric ESD, closure of the mucosal defect was performed using a FLEXLOOP with standard clips. The primary outcome was the complete closure rate. The secondary outcomes were procedure time, number of clips, sustained closure rate on second-look endoscopy on postoperative days (PODs) 5 to 7, and rate of post-ESD bleeding. Overall, 35 patients were included in this study. The median specimen size was 32 mm. The mucosal defect was completely closed in 31 patients (89%; 95% confidence interval, 73%-99%) and incompletely closed in four patients (11%). Median closure time was 11 minutes and median number of clips was 10. Second-look endoscopy performed on PODs 5 to 7 demonstrated sustained, partially sustained, and unsustained closures in seven (20%), 22 (63%), and six patients (17%), respectively. Post-ESD bleeding and complications related to FLEXLOOP were not observed. Closure using FLEXLOOP is feasible and safe. Our technique using this new device can be an attractive option for more easily closing mucosal defects. However, further clinical research is warranted to confirm that this technique can prevent delayed complications.

Schlagwörter

Stichwörter der Autor:innen

Barrett's and adenocarcinomaEndoscopic resection (ESD, EMRc, ...)Endoscopy Upper GI TractPrecancerous conditions & cancerous lesions (displasia and cancer) stomach

Autor:innen und Institutionen

  • Department of Gastroenterology, Kitakyushu Municipal Medical Center, Kitakyushu, Japan.
  • Gastroenterology, Kanagawa Cancer Center, Yokohama, Japan.
  • Department of Gastroenterology and Endoscopy, Koyukai Shin-Sapporo Hospital, Sapporo, Japan.
  • Gastroenterological Surgery, Osaka University Graduate School of Medicine, Suita, Japan.
  • Department of Gastroenterological Surgery, Osaka University Graduate School of Medicine, Suita, Japan.

ORCID-Profile: Kohei Takizawa, Yohei Nose, Taisuke Inada, Hironori Aoki, Yorinobu Sumida, Kiyokazu Nakajima

Förderung

  • Japan Consortium for Advanced Surgical Endoscopy

Zitieren

APA

Shiotsuki, K., Takizawa, K., Nose, Y., Kondo, Y., Homma, H., Inada, T., Daikaku, M., Maehara, K., Fukuda, S. I., Aoki, H., Sumida, Y., Akiho, H., Watari, J., & Nakajima, K. (2025). Endoscopic closure using a dedicated device following gastric endoscopic submucosal dissection: Multicenter, prospective, observational pilot study. Endoscopy International Open, 13(CP). https://doi.org/10.1055/a-2503-1684

Vancouver

Shiotsuki K, Takizawa K, Nose Y, Kondo Y, Homma H, Inada T, et al. Endoscopic closure using a dedicated device following gastric endoscopic submucosal dissection: Multicenter, prospective, observational pilot study. Endoscopy International Open. 2025;13(CP). doi:10.1055/a-2503-1684

BibTeX
@article{Shiotsuki2025,
  author = {Shiotsuki, Kazuo and Takizawa, Kohei and Nose, Yohei and Kondo, Yuki and Homma, Hitoshi and Inada, Taisuke and Daikaku, Mao and Maehara, Kosuke and Fukuda, Shin-Ichiro and Aoki, Hironori and Sumida, Yorinobu and Akiho, Hirotada and Watari, Jiro and Nakajima, Kiyokazu},
  title = {Endoscopic closure using a dedicated device following gastric endoscopic submucosal dissection: Multicenter, prospective, observational pilot study},
  journal = {Endoscopy International Open},
  year = {2025},
  volume = {13},
  number = {CP},
  doi = {10.1055/a-2503-1684}
}