Endoscopic submucosal dissection with adaptive traction: first prospective multicenter study
Endoscopy · 01.04.2024 · 56 (S 02 S 02) · S101
DOI: 10.1055/s-0044-1782908 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.04.2024. Verfasst von J. Grimaldi und 6 weiteren Autor:innen. Die Arbeit nennt 2 Literaturangaben.
Abstract (Originalsprache)
Aims
Traction has become the reference strategy for colorectal endoscopic submucosal dissection (ESD). One of its main limitations is that the power of traction decreases as dissection progresses. The ATRACT traction device uses a pulley system to increase traction during the procedure, making it simpler and faster. A retrospective study of 54 cases revealed interesting results in terms of efficacy and safety throughout the digestive tract. We sought to confirm these initial results with a prospective study of resections of colorectal lesions measuring 4 to 10 cm, in conventional locations (no recurrent lesions, appendicular, of the ileo-caecal valve, in contact with the pectineal line or measuring more than 2/3 of the circumference).
Methods
In this prospective multicenter study, 5 experienced operators from 3 different centers each performed 10 procedures using the ATRACT device consecutively for all conventional colorectal ESDs measuring between 4 and 10 cm. The ATRACT traction device used had 2 active loops and 2 free loops (ATRACT 2+2) and was manually manufactured.
Results
Between November 2022 and April 2023, 50 ESDs were performed in 49 patients. Lesions were located in the colon in 84% of cases and in the rectum in 16%. Device tightening was used in 72% of procedures. On average, the main diameter of the lesions was 66.6 mm, with a surface area of 3066 mm2. The average operating time was 55.2 minutes, resulting in a mean resection speed of 61.38 mm2/min. The en bloc and R0 resection rates were 100% and 98% respectively. Resections were curative in 94% of cases. 4 perforations (8%) occurred, all of which were closed endoscopically without the need for surgery. 1 case of delayed haemorrhage (2%) was noted. In 10 cases (20%), a technical failure occurred with the ATRACT device, but this did not prevent the procedure from being completed (in 6 cases, the device could not be tightened, and in 4 cases, one or more clips failed).
Conclusions
To date, this is the series demonstrating the highest resection speeds in the literature regarding colorectal ESD. By way of comparison, Yamamoto et al reported a speed of 23.5 mm2/min using the "pocket" strategy, and Bordillon et al noted a speed of 39.1 mm2/min with the double-clip traction technique. These results need to be confirmed in larger studies, and in non-expert centers. The adaptive traction strategy in ESD, via optimal exposure of the submucosa throughout the procedure, appears to bring significant benefits in terms of efficacy and safety. [ 1 ] [ 2 ] Publication History Article published online: 15 April 2024 © 2024. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
Zitieren
APA
Grimaldi, J., Masgnaux, L. J., Wallenhorst, T., Legros, R., Jerome, R., Jacques, J., & Mathieu, P. (2024). Endoscopic submucosal dissection with adaptive traction: first prospective multicenter study. Endoscopy, 56(S 02 S 02), S101. https://doi.org/10.1055/s-0044-1782908
Vancouver
Grimaldi J, Masgnaux LJ, Wallenhorst T, Legros R, Jerome R, Jacques J, et al. Endoscopic submucosal dissection with adaptive traction: first prospective multicenter study. Endoscopy. 2024;56(S 02 S 02):S101. doi:10.1055/s-0044-1782908
BibTeX
@article{Grimaldi2024,
author = {Grimaldi, J. and Masgnaux, L. J. and Wallenhorst, T. and Legros, R. and Jerome, R. and Jacques, J. and Mathieu, P.},
title = {Endoscopic submucosal dissection with adaptive traction: first prospective multicenter study},
journal = {Endoscopy},
year = {2024},
volume = {56},
number = {S 02 S 02},
pages = {S101},
doi = {10.1055/s-0044-1782908}
}
EUVIMED