Efficacy and safety of multi-loop traction device-assisted colorectal endoscopic submucosal dissection: Multicenter randomized clinical trial
Endoscopy International Open · 04.04.2025 · 13 (CP)
DOI: 10.1055/a-2466-0718 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Endoscopy International Open, erschienen am 04.04.2025. Verfasst von Mamoru Ito und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Endoscopy, The Jikei University School of Medicine, Minato-ku, Japan. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The Jikei University Collaborative Research Fund.
Abstract (Originalsprache)
The multi-loop traction device (MLTD) facilitates optimal visualization of the submucosa throughout endoscopic submucosal dissection (ESD). This trial aimed to assess the efficacy of MLTD for colorectal ESD. We conducted a multicenter, open-label, randomized controlled trial involving patients with colorectal lesions ≥ 20 mm suspicious for noninvasive carcinoma. Participants were randomly assigned in a 1:1 ratio to undergo ESD with MLTD (MLTD-ESD group) or ESD without any traction device (control group). Endoscopists were allowed to convert treatments if dissection became challenging for 10 minutes. The primary endpoint was dissection speed; secondary endpoints included technical success rate and adverse events (AEs). A total of 108 participants were randomized to the MLTD-ESD group (n = 53) and the control group (n = 55). There was no statistically significant difference in median dissection speed between the MLTD-ESD group and the control group (14.8 mm2/min; interquartile range [IQR] 8.9–23.9 mm2/min vs. 13.3 mm2/min; IQR 8.9–18.8 mm2/min) (P = 0.33). The technical success rate was significantly higher in the MLTD-ESD group (96.2%) compared with the control group (71.0%) (P < 0.0001). All technical failures were due to treatment conversions. No significant difference was observed in AEs. Subgroup analysis revealed that experts in the MLTD-ESD group had faster dissection speed than controls (21.6 mm2/min; IQR 15.5–28.8 mm2/min vs. 14.4 mm2/min; IQR 9.9–21.2 mm2/min) (P = 0.009). This multicenter randomized trial demonstrated that use of MLTD did not significantly increase dissection speed for colorectal ESD. Treatment conversions may have influenced the primary endpoint, and further investigation is warranted.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Endoscopy, The Jikei University School of Medicine, Minato-ku, Japan.
- Department of Gastroenterology, The University of Tokyo, Bunkyo-ku, Japan.
- Endoscopy Division, National Cancer Center Hospital, Chuo-ku, Japan.
ORCID-Profile: Hiroyuki Takamaru, Mitsuhiro Fujishiro
Förderung
- The Jikei University Collaborative Research Fund
Zitieren
APA
Ito, M., Miura, Y., Mizuguchi, Y., Furuhashi, H., Tsuji, Y., Takamaru, H., Tamai, N., Fujishiro, M., Saito, Y., & Sumiyama, K. (2025). Efficacy and safety of multi-loop traction device-assisted colorectal endoscopic submucosal dissection: Multicenter randomized clinical trial. Endoscopy International Open, 13(CP). https://doi.org/10.1055/a-2466-0718
Vancouver
Ito M, Miura Y, Mizuguchi Y, Furuhashi H, Tsuji Y, Takamaru H, et al. Efficacy and safety of multi-loop traction device-assisted colorectal endoscopic submucosal dissection: Multicenter randomized clinical trial. Endoscopy International Open. 2025;13(CP). doi:10.1055/a-2466-0718
BibTeX
@article{Ito2025,
author = {Ito, Mamoru and Miura, Yuko and Mizuguchi, Yasuhiko and Furuhashi, Hiroto and Tsuji, Yosuke and Takamaru, Hiroyuki and Tamai, Naoto and Fujishiro, Mitsuhiro and Saito, Yutaka and Sumiyama, Kazuki},
title = {Efficacy and safety of multi-loop traction device-assisted colorectal endoscopic submucosal dissection: Multicenter randomized clinical trial},
journal = {Endoscopy International Open},
year = {2025},
volume = {13},
number = {CP},
doi = {10.1055/a-2466-0718}
}
EUVIMED