EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieMultizentrische Studie

Efficacy of an internal traction device in colorectal endoscopic submucosal dissection: a multicenter randomized controlled trial

Shinya Taki, Mikitaka Iguchi, Kazuhiro Fukatsu, Tomoya Emori, Ikuharu Kinoshita, Makiko Kinoshita, Hiroshi Takihara, Shunsuke Ogata, Takao Maekita, Jun Kinoshita, Masaki Takao, Toshio Shimokawa und 2 weitere

Surgical Endoscopy · 2026-06 · 40 (6) · 5054-5063

DOI: 10.1007/s00464-026-12893-4 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Surgical Endoscopy, online erschienen am 26.05.2026. Verfasst von Shinya Taki und 13 weiteren Autor:innen. Beteiligte Einrichtung: Second Department of Internal Medicine, Wakayama Medical University, 811-1, Kimiidera, Wakayama, 641-8509, Japan. Hauptthemen laut MEDLINE: Endoscopic Mucosal Resection, Colorectal Neoplasms, Traction. Die Arbeit nennt 28 Literaturangaben. Gefördert von: ZEON Medical Inc.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND AND AIM: Shortening the procedure time and reducing the incidence of complications are important in patients undergoing colorectal endoscopic submucosal dissection (ESD). This prospective randomized controlled trial assessed the efficacy and safety of colorectal ESD with an internal traction-assisted device (IT-ESD) by comparing its outcomes with those of conventional ESD (without internal traction-assisted device) in patients with colorectal epithelial neoplasia. METHODS: A total of 201 patients who underwent ESD between March 2020 and April 2023 were prospectively randomized to IT-ESD or conventional ESD. The primary endpoint was procedure time. Secondary endpoints included rates of procedural complications, en bloc resection, curative resection, conversion, and adverse events. RESULTS: Mean procedure time was significantly shorter in patients who underwent IT-ESD than conventional ESD (95.8 ± 59.5 vs. 114.7 ± 68.3 min; p = 0.041). Although ESD trainees tended to take less time to perform IT-ESD than conventional ESD (103.2 ± 63.2 min vs 128.7 ± 76.2 min, p = 0.075), no statistically significant difference was observed. Overall complication rates associated with the procedure did not differ significantly who underwent IT-ESD and conventional ESD (13.0% vs. 17.8%; p = 0.435). Intraoperative perforations tended to be more common in conventional (7.1%) than IT-ESD (2.0%). When stratified by lesion location, procedure time was significantly shorter for IT-ESD than for conventional ESD at colon than rectum (92.9 ± 55.2 vs. 117.3 ± 69.3 min; p = 0.013). CONCLUSIONS: IT-ESD significantly reduces procedure time and may enhance procedural efficiency. Furthermore, IT-ESD may contribute to improved safety and is considered particularly advantageous for colonic lesions. TRIAL REGISTRATION: The Japan Registry of Clinical Trials (JRCT; trial registration: jRCT052190089). Registered on December 25, 2019. https://jrct.niph.go.jp/latest-detail/jRCTs052190089 jRCT052190089 Version number: 4.0. TRIAL STATUS: Protocol version number: 2.4.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Endoscopic Mucosal ResectionColorectal NeoplasmsTractionHumansFemaleMaleAgedProspective StudiesOperative TimeMiddle AgedPostoperative ComplicationsTreatment Outcome

Stichwörter der Autor:innen

Colorectal epithelial neoplasmESDTraction device

Autor:innen und Institutionen

  • Second Department of Internal Medicine, Wakayama Medical University, 811-1, Kimiidera, Wakayama, 641-8509, Japan.
  • Second Department of Internal Medicine, Wakayama Medical University, 811-1, Kimiidera, Wakayama, 641-8509, Japan. mikitaka@wakayama-med.ac.jp.
  • Department of Gastroenterology, Wakayama Rousai Hospital, Wakayama, Japan.
  • Department of Gastroenterology, National Hospital Organization Minami Wakayama Medical Center, Wakayama, Japan.
  • Department of Endoscopy, Kishiwada Tokushukai Hospital, Kishiwada, Japan.
  • Clinical Support Center, Wakayama Medical University, Wakayama, Japan.

Förderung

  • ZEON Medical Inc

Zitieren

APA

Taki, S., Iguchi, M., Fukatsu, K., Emori, T., Kinoshita, I., Kinoshita, M., Takihara, H., Ogata, S., Maekita, T., Kinoshita, J., Takao, M., Shimokawa, T., Kitano, M., & KENIN Study group (2026). Efficacy of an internal traction device in colorectal endoscopic submucosal dissection: a multicenter randomized controlled trial. Surgical Endoscopy, 40(6), 5054-5063. https://doi.org/10.1007/s00464-026-12893-4

Vancouver

Taki S, Iguchi M, Fukatsu K, Emori T, Kinoshita I, Kinoshita M, et al. Efficacy of an internal traction device in colorectal endoscopic submucosal dissection: a multicenter randomized controlled trial. Surgical Endoscopy. 2026;40(6):5054-5063. doi:10.1007/s00464-026-12893-4

BibTeX
@article{Taki2026,
  author = {Taki, Shinya and Iguchi, Mikitaka and Fukatsu, Kazuhiro and Emori, Tomoya and Kinoshita, Ikuharu and Kinoshita, Makiko and Takihara, Hiroshi and Ogata, Shunsuke and Maekita, Takao and Kinoshita, Jun and Takao, Masaki and Shimokawa, Toshio and Kitano, Masayuki and KENIN Study group, KENIN Study group},
  title = {Efficacy of an internal traction device in colorectal endoscopic submucosal dissection: a multicenter randomized controlled trial},
  journal = {Surgical Endoscopy},
  year = {2026},
  volume = {40},
  number = {6},
  pages = {5054--5063},
  doi = {10.1007/s00464-026-12893-4}
}
Kostenlos starten →