The Conversion of Unicompartmental Knee Arthroplasty to Total Knee Arthroplasty with Non-CT-Based Robotic Assistance: A Novel Surgical Technique and Case Series
The Journal of Knee Surgery · 01.02.2025 · 38 (03) · 141-147
DOI: 10.1055/a-2421-5496 ↗Kurz gefasst
Fallbericht in der Zeitschrift The Journal of Knee Surgery, erschienen am 01.02.2025. Verfasst von Hamza M Raja und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Henry Ford Hospital System, Detroit, Michigan. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Osteoarthritis, Knee, Robotic Surgical Procedures. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 31 Literaturangaben.
Abstract (Originalsprache)
Robotic-assisted devices help provide precise component positioning in conversion of unicompartmental knee arthroplasty (UKA) to total knee arthroplasty (TKA). A few studies offer surgical techniques for computed tomography (CT) based robotic-assisted conversion of UKA to TKA; however, no studies to date detail this procedure utilizing a non-CT-based robotic-assisted device. This article introduces a novel technique employing a non-CT-based robotic-assisted device (ROSA Knee System, Zimmer Biomet, Warsaw, IN) for converting UKA to TKA with a focus on its efficacy in gap balancing. We present three patients (ages 46–66 years) who were evaluated for conversion of UKA to TKA for aseptic loosening, stress fracture, and progressive osteoarthritis. Each patient underwent robotic-assisted conversion to TKA. Postoperative assessments at 6 months revealed improved pain, function, and radiographic stability. Preoperative planning included biplanar long leg radiographs to determine the anatomic and mechanical axis of the leg. After arthrotomy with a standard medial parapatellar approach, infrared reflectors were pinned into the femur and tibia, followed by topographical mapping of the knee with the UKA in situ. The intraoperative software was utilized to evaluate flexion and extension balancing and plan bony resections. Then, the robotic arm guided placement of the femoral and tibial guide pins and the UKA components were removed. After bony resection of the distal femur and proximal tibia, the intraoperative software was used to reassess the extension gap, and plan posterior condylar resection to have the flexion gap match the extension gap. The use of a non-CT-based robotic-assisted device in conversion of UKA to TKA is a novel technique and a good option for surgeons familiar with robotic-assisted arthroplasty, resulting in excellent outcomes at 6 months.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Orthopaedic Surgery, Henry Ford Hospital System, Detroit, Michigan.
ORCID-Profile: Hamza M Raja, Luke Wesemann
Zitieren
APA
Raja, H. M., Wesemann, L., Charters, M. A., & North, W. T. (2025). The Conversion of Unicompartmental Knee Arthroplasty to Total Knee Arthroplasty with Non-CT-Based Robotic Assistance: A Novel Surgical Technique and Case Series. The Journal of Knee Surgery, 38(03), 141-147. https://doi.org/10.1055/a-2421-5496
Vancouver
Raja HM, Wesemann L, Charters MA, North WT. The Conversion of Unicompartmental Knee Arthroplasty to Total Knee Arthroplasty with Non-CT-Based Robotic Assistance: A Novel Surgical Technique and Case Series. The Journal of Knee Surgery. 2025;38(03):141-147. doi:10.1055/a-2421-5496
BibTeX
@article{Raja2025,
author = {Raja, Hamza M and Wesemann, Luke and Charters, Michael A and North, W Trevor},
title = {The Conversion of Unicompartmental Knee Arthroplasty to Total Knee Arthroplasty with Non-CT-Based Robotic Assistance: A Novel Surgical Technique and Case Series},
journal = {The Journal of Knee Surgery},
year = {2025},
volume = {38},
number = {03},
pages = {141--147},
doi = {10.1055/a-2421-5496}
}
EUVIMED