EUVIMEDEUVIMED entdecken
Übersichtsarbeit

Boundaries in Kinematic Alignment: Why, When, and How

Pier Francesco Indelli iD, Giuseppe Petralia, Stefano Ghirardelli, Pieralberto Valpiana, Giuseppe Aloisi, Andrea Giordano Salvi, Salvatore Risitano

The Journal of Knee Surgery · 01.06.2025 · 38 (07) · 324-327

DOI: 10.1055/a-2395-6935 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift The Journal of Knee Surgery, erschienen am 01.06.2025. Verfasst von Pier Francesco Indelli und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Südtiroler Sanitätsbetrieb, Brixen, Italy. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Knee Joint. Die Arbeit nennt 31 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The use of alternative alignments in total knee arthroplasty (TKA) has recently been increasing in popularity: many of these alignments have been included in the broad spectrum of “kinematic alignment.” This alternative approach was recommended to increase patients' satisfaction since many studies based on patient-reported outcome measures (PROMs) showed that every fifth patient is not satisfied with the surgical outcome. In fact, the original kinematic alignment technique was designed as a “pure resurfacing” technique, maintaining the preoperative axes (flexion–extension and axial rotation) of the knee. In adjunct, many new classifications of the preoperative limb deformity have been proposed to include a large range of knee anatomies, few of them very atypical. Following those classifications, many surgeons aimed for a reproduction of unusual anatomies putting in jeopardy the survivorship of the implant according to the classical “dogma” of a poor knee kinematics and TKA biomechanics if the final hip–knee–ankle (HKA) axis was not kept within 5 degrees from neutral. This article reviews the literature supporting the choice of setting alignment boundaries in TKA when surgeons are interested in reproducing the constitutional knee anatomy of the patient within a safe range.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeKnee JointHumansBiomechanical PhenomenaKnee ProsthesisRange of Motion, Articular

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, Südtiroler Sanitätsbetrieb, Brixen, Italy.
  • Paracelsus Medical University (PMU), Institute of Biomechanics, Paracelsus Medical University, Salzburg, Austria.
  • CESAT, Azienda Sanitaria Toscana Centro, Fucecchio, Italy.
  • Department of Orthopaedic Surgery, Stanford University School of Medicine, Redwood City, California.
  • Dipartimento di Medicina Clinica, Sanita' Pubblica, Scienze della Vita e dell'Ambiente, Universita' degli Studi dell'Aquila, L'Aquila, Italy.
  • Department of Orthopaedics and Traumatology, University of Turin, CTO, Turin, Italy.

ORCID-Profile: Pier Francesco Indelli

Zitieren

APA

Indelli, P. F., Petralia, G., Ghirardelli, S., Valpiana, P., Aloisi, G., Salvi, A. G., & Risitano, S. (2025). Boundaries in Kinematic Alignment: Why, When, and How. The Journal of Knee Surgery, 38(07), 324-327. https://doi.org/10.1055/a-2395-6935

Vancouver

Indelli PF, Petralia G, Ghirardelli S, Valpiana P, Aloisi G, Salvi AG, et al. Boundaries in Kinematic Alignment: Why, When, and How. The Journal of Knee Surgery. 2025;38(07):324-327. doi:10.1055/a-2395-6935

BibTeX
@article{Indelli2025,
  author = {Indelli, Pier Francesco and Petralia, Giuseppe and Ghirardelli, Stefano and Valpiana, Pieralberto and Aloisi, Giuseppe and Salvi, Andrea Giordano and Risitano, Salvatore},
  title = {Boundaries in Kinematic Alignment: Why, When, and How},
  journal = {The Journal of Knee Surgery},
  year = {2025},
  volume = {38},
  number = {07},
  pages = {324--327},
  doi = {10.1055/a-2395-6935}
}
Kostenlos starten →