Fachartikel in der Zeitschrift Applied Clinical Informatics, erschienen am 01.08.2024. Verfasst von Sarah A Thompson und 7 weiteren Autor:innen. Beteiligte Einrichtung: Information Services and Technology, Children's Healthcare of Atlanta, Atlanta, Georgia, United States. Hauptthemen laut MEDLINE: Medical Order Entry Systems. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Blood product ordering is a complex process and mistakes can harm patients and lead to poor outcomes. Orders and order sets can be designed to help mitigate errors, but major changes in design can unintentionally cause new errors.

Objectives

Our objective was as follows: (1) utilize formative in situ usability testing to iteratively improve the design of a redesigned blood product order set prior to go-live, (2) implement changes based on feedback derived from this testing, and (3) compare the error rate, system usability scale (SUS) score, time to task completion, and click counts between the prior order set in use at the time and the revised redesigned order set.

Methods

A multidisciplinary project team convened to redesign blood product orders and order sets from scratch based on a review of the literature and benchmarking against four pediatric academic institutions with the goal of addressing prior ordering errors. The newly redesigned blood product order set was iteratively updated via in situ formative usability testing performed with available clinical users using a concurrent think-aloud protocol in real clinical environments. Errors, SUS scores, time to task completion, and click counts were assessed for the revised redesigned order set using summative testing.

Results

Formative usability testing with 20 participants led to seven design changes in the redesigned order set which reduced the error rate at go-live. Summative usability testing showed that even though the usability scores were only slightly improved for the revised redesigned order set, the error rates in blood orders were significantly decreased.

Conclusion

Usability testing can identify design errors early in the process which can be rectified prior to implementation, thus avoiding unintended consequences of changes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Medical Order Entry SystemsHumansChildUser-Computer InterfaceBlood TransfusionMedical Errors

Autor:innen und Institutionen

  • Information Services and Technology, Children's Healthcare of Atlanta, Atlanta, Georgia, United States.
  • Emory University School of Medicine, Atlanta, Georgia, United States.

Zitieren

APA

Thompson, S. A., Williams, H., Rzewnicki, D., Orenstein, E., Carter, A. B., Rollins, M., Rogers, B., & Kandaswamy, S. (2024). Avoiding Unintended Consequences of Pediatric Blood Order Set Updates through In Situ Usability Testing. Applied Clinical Informatics, 15(04), 763-770. https://doi.org/10.1055/a-2351-9642

Vancouver

Thompson SA, Williams H, Rzewnicki D, Orenstein E, Carter AB, Rollins M, et al. Avoiding Unintended Consequences of Pediatric Blood Order Set Updates through In Situ Usability Testing. Applied Clinical Informatics. 2024;15(04):763-770. doi:10.1055/a-2351-9642

BibTeX
@article{Thompson2024,
  author = {Thompson, Sarah A and Williams, Herb and Rzewnicki, Daniel and Orenstein, Evan and Carter, Alexis B and Rollins, Margo and Rogers, Beverly and Kandaswamy, Swaminathan},
  title = {Avoiding Unintended Consequences of Pediatric Blood Order Set Updates through In Situ Usability Testing},
  journal = {Applied Clinical Informatics},
  year = {2024},
  volume = {15},
  number = {04},
  pages = {763--770},
  doi = {10.1055/a-2351-9642}
}
Kostenlos starten →