EUVIMEDEUVIMED entdecken
Crossref

Electronic positive patient identification, computer provider order entry, and electronic remote blood issue implemented in operating rooms improve the safety and efficiency of blood transfusions

Nathan A Williams iD, Magali J Fontaine, Erika Reese, Megan Anders, Peter Rock, Parvez M Lokhandwala, Ashanpreet S Grewal

Laboratory Medicine · 2025

DOI: 10.1093/labmed/lmae122 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Laboratory Medicine, 2025. Verfasst von Nathan A Williams und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pathology, University of Maryland School of Medicine, Baltimore, MD, US. Hauptthemen laut MEDLINE: Blood Transfusion, Operating Rooms, Medical Order Entry Systems, Patient Identification Systems. Die Arbeit nennt 15 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Blood transfusions are routinely performed in operation rooms. The process chain of performing ABO type, antibody screen, crossmatch, blood transport, and patient verification is complex. A multidisciplinary task force convened to improve the process of blood ordering and utilization identified 3 issues: (1) blood orders performed on paper included transcription errors; (2) guidelines for blood ordering practices were lacking, with inappropriate and arbitrary requests; and (3) there were long intervals between ordering and receiving blood in the operating room because of its distance from the blood bank.

Methods

The task force implemented (1) an electronic positive patient identification (ePPID) system, (2) a standardized computer provider order entry (CPOE) for ordering blood for surgical patients, and (3) an electronic remote blood issuing (ERBI) system using refrigerators located within the operating suite.

Results

Following ePPID implementation, transfusion documentation compliance rates improved from 71% to 98% and detected 2 patient safety issues. Implementation of CPOE with a maximum surgical blood order schedule and ERBI led to a substantial decline in blood product dispensed from coolers and reduced returns of unused red blood cells (from 30% to 15%) and plasma units (from 45% to 30%) to the blood bank over 2 years.

Discussion

Electronic PPID, CPOE, and ERBI improved patient safety, workflow, and efficiency during blood transfusions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Blood TransfusionOperating RoomsMedical Order Entry SystemsPatient Identification SystemsPatient SafetyHumans

Stichwörter der Autor:innen

computer provider order entryelectronic positive patient identificationelectronic remove blood issuemanual positive patient identificationmaximal surgical blood order scheduletransfusion efficiencytransfusion safety

Autor:innen und Institutionen

  • Department of Pathology, University of Maryland School of Medicine, Baltimore, MD, US.
  • Division of Transfusion Medicine, University of Maryland Medical Center, Baltimore, MD, US.
  • Department of Anesthesiology, University of Maryland School of Medicine, Baltimore, MD, US.

ORCID-Profile: Nathan A Williams

Zitieren

APA

Williams, N. A., Fontaine, M. J., Reese, E., Anders, M., Rock, P., Lokhandwala, P. M., & Grewal, A. S. (2025). Electronic positive patient identification, computer provider order entry, and electronic remote blood issue implemented in operating rooms improve the safety and efficiency of blood transfusions. Laboratory Medicine. https://doi.org/10.1093/labmed/lmae122

Vancouver

Williams NA, Fontaine MJ, Reese E, Anders M, Rock P, Lokhandwala PM, et al. Electronic positive patient identification, computer provider order entry, and electronic remote blood issue implemented in operating rooms improve the safety and efficiency of blood transfusions. Laboratory Medicine. 2025. doi:10.1093/labmed/lmae122

BibTeX
@article{Williams2025,
  author = {Williams, Nathan A and Fontaine, Magali J and Reese, Erika and Anders, Megan and Rock, Peter and Lokhandwala, Parvez M and Grewal, Ashanpreet S},
  title = {Electronic positive patient identification, computer provider order entry, and electronic remote blood issue implemented in operating rooms improve the safety and efficiency of blood transfusions},
  journal = {Laboratory Medicine},
  year = {2025},
  doi = {10.1093/labmed/lmae122}
}
Kostenlos starten →