Fachartikel in der Zeitschrift Journal of Reconstructive Microsurgery Open, erschienen am 01.07.2023. Verfasst von Kai J. Wessel und 9 weiteren Autor:innen. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Recovery Assistance for Cohesion and the Territories of Europe.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The concept of robotic microsurgery is becoming increasingly known as several robotic systems tailored to the specific needs of microsurgery are being introduced. Training with these devices is essential to draw conclusions about their potential clinical utility. This study describes the training and learning curve of experienced microsurgeons and complete novices using such a robotic surgical system in combination with an exoscope.

Methods

Four experienced microsurgeons and three complete novices performed a total of 62 manual and robot-assisted anastomoses. The time for anastomosis completion and surgeon's satisfaction with the anastomosis and with the robotic system were recorded. The anastomoses' quality was assessed using the Structured Assessment of Microsurgery Skills (SAMS) and the Anastomosis Lapse Index (ALI). The Rapid Entire Body Assessment (REBA) was used for ergonomics evaluation.

Results

All expert microsurgeons and novices improved their performance during training. The average anastomosis time decreased significantly, while satisfaction with the anastomosis and robotic system increased significantly over time. Multiple SAMS score parameters increased significantly throughout robotic but not manual training and the ALI score demonstrated more errors in the manual group. The REBA score displayed a significantly lower risk for musculoskeletal disorders in the robotic group.

Conclusion

Currently, the first clinical applications of robotic surgical systems specifically designed for microsurgery are being reported. The introduction of such systems into clinical practice can be expected to have a steep learning curve, as demonstrated in our study. Meanwhile, robotic systems for microsurgical procedures may hold great potential for improvement of surgical quality and ergonomics.

Förderung

  • Recovery Assistance for Cohesion and the Territories of Europe

Zitieren

APA

Wessel, K. J., Wendenburg, I., Gorji, S., Dermietzel, A., Aitzetmueller, M. M., Varnava, C., Wiebringhaus, P., Klietz, M., Hirsch, T., & Kueckelhaus, M. (2023). Combined Application of a Novel Robotic System and Exoscope for Microsurgical Anastomoses: Preclinical Performance. Journal of Reconstructive Microsurgery Open, 08(02), e88-e96. https://doi.org/10.1055/a-2199-2584

Vancouver

Wessel KJ, Wendenburg I, Gorji S, Dermietzel A, Aitzetmueller MM, Varnava C, et al. Combined Application of a Novel Robotic System and Exoscope for Microsurgical Anastomoses: Preclinical Performance. Journal of Reconstructive Microsurgery Open. 2023;08(02):e88-e96. doi:10.1055/a-2199-2584

BibTeX
@article{Wessel2023,
  author = {Wessel, Kai J. and Wendenburg, Isa and Gorji, Shaghayegh and Dermietzel, Alexander and Aitzetmueller, Matthias M. and Varnava, Charalampos and Wiebringhaus, Philipp and Klietz, Marie-Luise and Hirsch, Tobias and Kueckelhaus, Maximilian},
  title = {Combined Application of a Novel Robotic System and Exoscope for Microsurgical Anastomoses: Preclinical Performance},
  journal = {Journal of Reconstructive Microsurgery Open},
  year = {2023},
  volume = {08},
  number = {02},
  pages = {e88--e96},
  doi = {10.1055/a-2199-2584}
}
Kostenlos starten →