Comparison of Biomechanical and Histopathological Properties of Robot-Assisted Anastomoses Using the Symani Surgical System® versus Conventional Anastomoses in a Preclinical Microsurgical Model
Journal of Reconstructive Microsurgery · 01.02.2026 · 42 (02) · 172-180
DOI: 10.1055/a-2596-5437 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Reconstructive Microsurgery, erschienen am 01.02.2026. Verfasst von Vincent G J Guillaume und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Plastic Surgery, Hand and Reconstructive Surgery, University Hospital RWTH Aachen, Aachen, Germany. Hauptthemen laut MEDLINE: Anastomosis, Surgical, Microsurgery, Robotic Surgical Procedures, Suture Techniques. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 25 Literaturangaben.
Abstract (Originalsprache)
The Symani surgical system (Symani) is the first robotic system specifically designed for microsurgical purposes and attracted substantial interest in recent times. Despite some initial investigations, no independent analysis of the histopathological/biomechanical properties and anastomoses quality of Symani-sutured anastomoses have been conducted so far. This study aims to compare in-depth robotic-assisted microsurgical anastomoses using the Symani versus conventional anastomoses regarding anastomosis quality, biomechanical, and histopathological properties. We compared 12 microsurgical end-to-end anastomoses sewn by the Symani versus 12 by the conventional technique in a preclinical artery chicken-thigh-model regarding time until completion of the anastomosis, anastomosis quality (modified MARS10-rating and anastamosis lapse index (ALI)) and diameter. Additionally, histopathological analysis of the thread hole diameter, and knot firmness as well as biomechanical tests for intraluminal resistance and tensile strength of the anastomoses were conducted. Anastomosis quality was comparable between both techniques. The Symani-assisted anastomosis took a significantly longer time to perform than conventional anastomosis. Histopathological analysis revealed similar vessel wall damage while showing greater variability in knot spacing and bite width in the robotic anastomoses. No significant differences were observed in the tensile strength test or intraluminal resistance. However, the knot firmness of Symani-assisted anastomosis was significantly less than conventionally performed knots. This study demonstrates that the Symani performs on par with conventional anastomosis techniques regarding anastomosis quality, vessel wall damage, intraluminal resistance, and tensile strength. Long-term continuous training and/or further innovations of the Symani system may lower the time required to perform the anastomosis and improve knot firmness.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Plastic Surgery, Hand and Reconstructive Surgery, University Hospital RWTH Aachen, Aachen, Germany.
- Institute for Pathology, University Hospital RWTH Aachen, Aachen, Germany.
- Department of Orthopedic Surgery, Trauma and Reconstructive Surgery, University Hospital RWTH Aachen, Aachen, Germany.
- German Center for Lung Research (DZL), BREATH Hannover, Hanover, Germany.
ORCID-Profile: Vincent G J Guillaume
Zitieren
APA
Guillaume, V. G. J., Ammo, T., Leypold, S., Praster, M., Jonigk, D., Beier, J. P., & Leypold, T. (2026). Comparison of Biomechanical and Histopathological Properties of Robot-Assisted Anastomoses Using the Symani Surgical System® versus Conventional Anastomoses in a Preclinical Microsurgical Model. Journal of Reconstructive Microsurgery, 42(02), 172-180. https://doi.org/10.1055/a-2596-5437
Vancouver
Guillaume VGJ, Ammo T, Leypold S, Praster M, Jonigk D, Beier JP, et al. Comparison of Biomechanical and Histopathological Properties of Robot-Assisted Anastomoses Using the Symani Surgical System® versus Conventional Anastomoses in a Preclinical Microsurgical Model. Journal of Reconstructive Microsurgery. 2026;42(02):172-180. doi:10.1055/a-2596-5437
BibTeX
@article{Guillaume2026,
author = {Guillaume, Vincent G J and Ammo, Tekoshin and Leypold, Sophie and Praster, Maximilian and Jonigk, Danny and Beier, Justus P and Leypold, Tim},
title = {Comparison of Biomechanical and Histopathological Properties of Robot-Assisted Anastomoses Using the Symani Surgical System® versus Conventional Anastomoses in a Preclinical Microsurgical Model},
journal = {Journal of Reconstructive Microsurgery},
year = {2026},
volume = {42},
number = {02},
pages = {172--180},
doi = {10.1055/a-2596-5437}
}
EUVIMED