Point-of-Care Ultrasound for the Tip of the Endotracheal Tube: A Neonatologist Perspective
American Journal of Perinatology · 01.05.2024 · 41 (S 01 S 01) · e2886-e2892
DOI: 10.1055/a-2181-7354 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift American Journal of Perinatology, erschienen am 01.05.2024. Verfasst von Ozlem Sahin und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neonatology, Health Sciences University, Umraniye Training and Research Hospital, Istanbul, Türkiye. Hauptthemen laut MEDLINE: Intubation, Intratracheal, Point-of-Care Systems, Ultrasonography. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 13 Literaturangaben.
Abstract (Originalsprache)
Objective
Point-of-care ultrasound (POCUS) has been reported to reduce radiation exposure and has been shown to be a reliable bedside technique to confirm endotracheal tube (ETT) placement, but evidence in neonates is still limited. The aim of this study was to compare the effectiveness and reliability of POCUS performed by a neonatologist, as an alternative to chest radiography (CXR) for the optimal position of ETT. Study Design Newborns who underwent intubation were included in this prospective observational study. The CXR was used to evaluate the position of the ETT tip and categorized into three groups: above the T1, between the T1 and T3, and below the T3 vertebra. An experienced neonatologist measured the distance between the ETT tip and the upper border of the aortic arch from the suprasternal notch with ultrasonography (US). A 5 to 10 mm measurement was considered as the optimal distance, and the position was classified into three categories: correct, high, and deep.
Results
Among 91 measurements performed on 63 intubated patients with US, 73 (80%) were within the 5 to 10 mm range (correct position). Of these, 61 (92.4%) were determined to be between T1 and 3 vertebrae in CXR. There was no significant difference between the two methods, and the US had an excellent ability to distinguish the correct position of the ETT. The distance measured by the US for the ETT tip to be located between the T1 and T3 vertebrae on CXR should range between 6.17 and 9.0 mm.
Conclusion
This study showed that the US by an experienced neonatologist is an easy and feasible alternative to determine the position of the ETT in the neonatal intensive care unit. Key Points
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Neonatology, Health Sciences University, Umraniye Training and Research Hospital, Istanbul, Türkiye.
- Department of Radiology, Health Sciences University, Umraniye Training and Research Hospital, Istanbul, Türkiye.
Zitieren
APA
Sahin, O., Tasar, S., Colak, D., Yavanoglu Atay, F., Guran, O., & Mungan Akin, I. (2024). Point-of-Care Ultrasound for the Tip of the Endotracheal Tube: A Neonatologist Perspective. American Journal of Perinatology, 41(S 01 S 01), e2886-e2892. https://doi.org/10.1055/a-2181-7354
Vancouver
Sahin O, Tasar S, Colak D, Yavanoglu Atay F, Guran O, Mungan Akin I. Point-of-Care Ultrasound for the Tip of the Endotracheal Tube: A Neonatologist Perspective. American Journal of Perinatology. 2024;41(S 01 S 01):e2886-e2892. doi:10.1055/a-2181-7354
BibTeX
@article{Sahin2024,
author = {Sahin, Ozlem and Tasar, Sevinc and Colak, Derya and Yavanoglu Atay, Funda and Guran, Omer and Mungan Akin, Ilke},
title = {Point-of-Care Ultrasound for the Tip of the Endotracheal Tube: A Neonatologist Perspective},
journal = {American Journal of Perinatology},
year = {2024},
volume = {41},
number = {S 01 S 01},
pages = {e2886--e2892},
doi = {10.1055/a-2181-7354}
}