EUVIMEDEUVIMED entdecken
Crossref

Diagnostic accuracy of airway ultrasound in confirming the endotracheal tube depth in critically ill children

Souraja Datta, Jhuma Sankar, Mona Pathak, Sagar Tungal, Devasenathipathy Kandasamy, Nitin Dhochak, Kana Ram Jat, Rakesh Lodha

The American Journal of Emergency Medicine · 2024-11 · 85 · 52-58

DOI: 10.1016/j.ajem.2024.08.012 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The American Journal of Emergency Medicine, 2024-11. Verfasst von Souraja Datta und 7 weiteren Autor:innen. Beteiligte Einrichtung: Division of Pediatric Pulmonology and Intensive Care, Department of Pediatrics, All India Institute of Medical Sciences, New Delhi, India. Hauptthemen laut MEDLINE: Intubation, Intratracheal, Ultrasonography, Critical Illness, Trachea. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 28 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Chest X-ray, the established standard of confirming endotracheal tube (ETT) position, has important drawbacks including radiation exposure. Point-of-care airway ultrasound, which has been insufficiently studied in children, can overcome these problems. MATERIALS AND METHODS: This was a prospective cross-sectional study done on children aged 2 months to 17 years undergoing intubation with cuffed ETT in the PICU. The ETT cuff was filled with saline and three ultrasonographic techniques were used- 1) Suprasternal (SS) method 2) Cricoid (CC) metho and 3) Tracheal ring (TR) method. Position of the ETT as determined by ultrasound and X-ray were compared. The main outcomes were sensitivity, specificity, and area under curve (AUC) for ultrasound-based methods vs. X-ray. For the TR method, concordance between the X-ray and ultrasound categories were taken. RESULTS: Total 62 patients were enrolled. The sensitivity and specificity of SS method were 71% (95% CI: 57-83%) and 100% (40-100%). The CC distance method had an AUC of 0.94 (95% CI: 0.86, 1.0). In the TR method, 98% of correct position on X-ray were correctly classified by USG. The agreement between X-ray and ultrasound categories with the cuff between the first and third tracheal rings, was very good [kappa (95% CI): 0.87 (0.70, 1.00), p ≤0.001)]. CONCLUSION: Bedside ultrasound is a good method to confirm ETT depth in children. The tracheal ring method had the best diagnostic accuracy and is easy to perform. The new method using cricoid cuff distance needs further validation in different ICU settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Intubation, IntratrachealUltrasonographyCritical IllnessTracheaSensitivity and SpecificityHumansChild, PreschoolChildProspective StudiesCross-Sectional StudiesMaleInfantFemaleAdolescentPoint-of-Care SystemsIntensive Care Units, Pediatric

Stichwörter der Autor:innen

Endotracheal tube positionLongitudinal viewTracheal ringsTransverse viewUSGX-ray

Autor:innen und Institutionen

  • Division of Pediatric Pulmonology and Intensive Care, Department of Pediatrics, All India Institute of Medical Sciences, New Delhi, India.
  • Division of Pediatric Pulmonology and Intensive Care, Department of Pediatrics, All India Institute of Medical Sciences, New Delhi, India. Electronic address: jhumasankar@aiims.edu.
  • Department of Biostatistics, Kalinga Institute of Medical Sciences, Bhubaneshwar, India.
  • Department of Radiology, All India Institute of Medical Sciences, New Delhi, India.

Zitieren

APA

Datta, S., Sankar, J., Pathak, M., Tungal, S., Kandasamy, D., Dhochak, N., Jat, K. R., & Lodha, R. (2024). Diagnostic accuracy of airway ultrasound in confirming the endotracheal tube depth in critically ill children. The American Journal of Emergency Medicine, 85, 52-58. https://doi.org/10.1016/j.ajem.2024.08.012

Vancouver

Datta S, Sankar J, Pathak M, Tungal S, Kandasamy D, Dhochak N, et al. Diagnostic accuracy of airway ultrasound in confirming the endotracheal tube depth in critically ill children. The American Journal of Emergency Medicine. 2024;85:52-58. doi:10.1016/j.ajem.2024.08.012

BibTeX
@article{Datta2024,
  author = {Datta, Souraja and Sankar, Jhuma and Pathak, Mona and Tungal, Sagar and Kandasamy, Devasenathipathy and Dhochak, Nitin and Jat, Kana Ram and Lodha, Rakesh},
  title = {Diagnostic accuracy of airway ultrasound in confirming the endotracheal tube depth in critically ill children},
  journal = {The American Journal of Emergency Medicine},
  year = {2024},
  volume = {85},
  pages = {52--58},
  doi = {10.1016/j.ajem.2024.08.012}
}
Kostenlos starten →