Treatment of walled-off necrosis using lumen-apposing metal stents versus plastic stents: a systematic review and meta-analysis of data from randomized trials
Endoscopy · 2024-03 · 56 (03) · 184-195
DOI: 10.1055/a-2169-0362 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift Endoscopy, online erschienen am 07.11.2023. Verfasst von Ji Young Bang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Digestive Health Institute, Orlando Health, Orlando, United States. Hauptthemen laut MEDLINE: Drainage, Pancreatitis, Acute Necrotizing, Plastics, Stents. Die Arbeit wurde bisher 31-mal zitiert (Crossref) und nennt 19 Literaturangaben.
Abstract (Originalsprache)
Background
Walled-off necrosis (WON) is highly morbid disease most effectively managed by endoscopic drainage with lumen-apposing metal stents (LAMSs) or plastic stents, with or without necrosectomy. This meta-analysis compared the clinical outcomes of patients included in randomized trials treated using LAMSs or plastic stents.
Methods
The MEDLINE and EMBASE databases were searched to identify all data collected from randomized trials comparing LAMSs and plastic stents for the treatment of WON. The primary outcome measure was need for endoscopic necrosectomy.
Results
Three studies comprising 206 patients met inclusion criteria. Except for procedure duration, which was significantly shorter for LAMSs (standardized mean difference [SMD] −1.22, 95%CI −1.64 to −0.79), there was no significant difference in need for necrosectomy (38.5% vs. 41.2%; risk ratio [RR] 1.07, 95%CI 0.79–1.45), number of interventions (SMD −0.09, 95%CI −0.40 to 0.22), treatment success (90.7% vs. 94.5%; RR 0.96, 95%CI 0.87–1.06), recurrence (4.6% vs. 0.6%; RR 3.73, 95%CI 0.42–33.0), readmission (42.6% vs. 50.2%; RR 0.84, 95%CI 0.62–1.14), length of hospitalization (SMD −0.06, 95%CI −0.55 to 0.43), mortality (8.5% vs. 9.8%; RR 0.70, 95%CI 0.30–1.66), new-onset organ failure (10.6% vs. 14.6%; RR 0.72, 95%CI 0.16–3.32), bleeding (11.0% vs. 10.7%; RR 1.09, 95%CI 0.34–3.44), procedural adverse events (23.6% vs. 19.2%; RR 1.38, 95%CI 0.82–2.33), or overall costs (SMD −0.04, 95%CI −0.31 to 0.24) between LAMSs and plastic stents, respectively.
Conclusions
Except for procedure duration, there is no significant difference in clinical outcomes for patients with WON treated using LAMSs or plastic stents.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Digestive Health Institute, Orlando Health, Orlando, United States.
Zitieren
APA
Bang, J. Y., Wilcox, C. M., Navaneethan, U., Hawes, R. H., & Varadarajulu, S. (2024). Treatment of walled-off necrosis using lumen-apposing metal stents versus plastic stents: a systematic review and meta-analysis of data from randomized trials. Endoscopy, 56(03), 184-195. https://doi.org/10.1055/a-2169-0362
Vancouver
Bang JY, Wilcox CM, Navaneethan U, Hawes RH, Varadarajulu S. Treatment of walled-off necrosis using lumen-apposing metal stents versus plastic stents: a systematic review and meta-analysis of data from randomized trials. Endoscopy. 2024;56(03):184-195. doi:10.1055/a-2169-0362
BibTeX
@article{Bang2024,
author = {Bang, Ji Young and Wilcox, Charles Melbern and Navaneethan, Udayakumar and Hawes, Robert Holbrook and Varadarajulu, Shyam},
title = {Treatment of walled-off necrosis using lumen-apposing metal stents versus plastic stents: a systematic review and meta-analysis of data from randomized trials},
journal = {Endoscopy},
year = {2024},
volume = {56},
number = {03},
pages = {184--195},
doi = {10.1055/a-2169-0362}
}