A comparison of novel electrocautery-enhanced lumen-apposing metal stents and plastic stents in endoscopic ultrasound-guided drainage of infected walled-off necrosis: a multicenter randomized study
Endoscopy · 2024-12 · 56 (12) · 926-937
DOI: 10.1055/a-2342-1140 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Endoscopy, online erschienen am 07.08.2024. Verfasst von Jong Ho Moon und 8 weiteren Autor:innen. Beteiligte Einrichtung: Division of Gastroenterology, Department of Internal Medicine, SoonChunHyang University College of Medicine, Bucheon, Korea (the Republic of). Hauptthemen laut MEDLINE: Drainage, Stents, Endosonography, Pancreatitis, Acute Necrotizing. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: SoonChunHyang University Research Fund.
Abstract (Originalsprache)
Background
Although lumen-apposing metal stents (LAMSs) have been increasingly used for walled-off necrosis (WON), their advantages over plastic stents in infected WON are unclear. We investigated the safety and efficacy of a novel electrocautery-enhanced LAMS for managing infected WON.
Methods
Patients who required endoscopic ultrasound-guided WON drainage were randomly assigned to LAMS or plastic stent groups. The primary outcome was total number of direct endoscopic necrosectomy (DEN) procedures required to achieve clinical success. Secondary outcomes included rates of technical success, clinical success, and adverse events.
Results
46 patients were included in the LAMS (n = 23) and plastic stent (n = 23) groups. The median total number of DEN procedures did not differ significantly between the plastic stent group (4 procedures, interquartile range [IQR] 2.5–5.0) and LAMS group (9 procedures, IQR 8.0–9.0) (P = 0.07). The LAMS group demonstrated a significantly higher clinical success rate than the plastic stent group based on intention-to-treat analysis (100% vs. 73.9%, P =0.03) at 8 weeks but not at 4 weeks. Significant bleeding occurred in one patient in the plastic stent group and no patients in the LAMS group.
Conclusions
We found no significant difference in the total number of DEN procedures between LAMSs and plastic stents for managing infected WON. The only statistically significant finding was a higher clinical success rate at 8 weeks for patients treated with LAMS. The use of LAMS did not result in any adverse events, such as bleeding or buried LAMS syndrome, within the study duration.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Division of Gastroenterology, Department of Internal Medicine, SoonChunHyang University College of Medicine, Bucheon, Korea (the Republic of).
- Division of Gastroenterology, Department of Internal Medicine, Hallym University Dongtan Sacred Heart Hospital, Hallym University College of Medicine, Hwaseong, Korea (the Republic of).
- Division of Gastroenterology, Department of Internal Medicine, Seoul National University College of Medicine, Seoul, Korea (the Republic of).
- Department of Internal Medicine, Research Institute of Clinical Medicine of Jeonbuk National University-Biomedical Research Institute of Jeonbuk National University Hospital, Jeonju, Korea (the Republic of).
- Division of Gastroenterology, Department of Internal Medicine, School of Medicine, Kyungpook National University, Daegu, Korea (the Republic of).
- Division of Gastroenterology, Department of Internal Medicine, Yeungnam University College of Medicine, Daegu, Korea (the Republic of).
ORCID-Profile: Se Woo Park, Sang Hyub Lee, Chan Hyuk Park
Förderung
- SoonChunHyang University Research Fund
Zitieren
APA
Moon, J. H., Park, S. W., Lee, Y. N., Lee, S. H., Kim, S. H., Lee, D. W., Cho, C. M., Kim, S. B., & Park, C. H. (2024). A comparison of novel electrocautery-enhanced lumen-apposing metal stents and plastic stents in endoscopic ultrasound-guided drainage of infected walled-off necrosis: a multicenter randomized study. Endoscopy, 56(12), 926-937. https://doi.org/10.1055/a-2342-1140
Vancouver
Moon JH, Park SW, Lee YN, Lee SH, Kim SH, Lee DW, et al. A comparison of novel electrocautery-enhanced lumen-apposing metal stents and plastic stents in endoscopic ultrasound-guided drainage of infected walled-off necrosis: a multicenter randomized study. Endoscopy. 2024;56(12):926-937. doi:10.1055/a-2342-1140
BibTeX
@article{Moon2024,
author = {Moon, Jong Ho and Park, Se Woo and Lee, Yun Nah and Lee, Sang Hyub and Kim, Seong-Hun and Lee, Dong Wook and Cho, Chang Min and Kim, Sung Bum and Park, Chan Hyuk},
title = {A comparison of novel electrocautery-enhanced lumen-apposing metal stents and plastic stents in endoscopic ultrasound-guided drainage of infected walled-off necrosis: a multicenter randomized study},
journal = {Endoscopy},
year = {2024},
volume = {56},
number = {12},
pages = {926--937},
doi = {10.1055/a-2342-1140}
}
EUVIMED