Rat Microvascular Model is Tolerant to Technical Errors
Journal of Reconstructive Microsurgery · 01.05.2024 · 40 (04) · 245-252
DOI: 10.1055/a-2153-2467 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Reconstructive Microsurgery, erschienen am 01.05.2024. Verfasst von Joseph R Paladino und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, Columbia University Irving Medical Center, New York, New York. Hauptthemen laut MEDLINE: Vascular Surgical Procedures, Lower Extremity. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 29 Literaturangaben. Gefördert von: Orthopedic Scientific Research Foundation.
Abstract (Originalsprache)
Background
Extensive studies have been conducted using the rat model to understand the potential technical errors that lead to anastomotic failure. However, current literature indicates that the rat model has excellent tolerance to diverse errors committed by microsurgeons. The error-investigating rat model is often created by one or two experienced surgeons, and only one isolated technical error is examined. These biases may potentially cause limitations of the results from previous studies. Meanwhile, venous anastomoses have rarely been investigated in previous literature. Therefore, it is important to elucidate this topic with a more comprehensive study design.
Methods
Ninety-four arterial and 94 venous anastomoses on Sprague–Dawley rat femoral vessels that were performed by 47 microsurgeons who participated in the microsurgery course at the Columbia University and the University of Thessaloniki were evaluated. In total, 10 technical errors were examined: (1) disruption of suture line, (2) back-wall stitch, (3) oblique stitch, (4) wide bite, (5) partial thickness bite, (6) unequal suture distance, (7) tear in vessel wall, (8) excessively tight suture, (9) suture threads in lumen, and (10) large edge overlap. The frequency of each error committed, and the 30-minute postoperative patency was also recorded. The underlying causal relationship between these errors, potential interaction, and the short-term anastomosis patency was analyzed statistically.
Results
Only the back-wall stitch was found to have a significant causal effect on arterial anastomosis failure (p < 0.001). Back-wall stitch, wide bite, and partial thickness bite significantly impact venous anastomosis patency (p < 0.001). No other statistically significant result was found.
Conclusion
Overall, the rat model is highly resilient to various technical errors despite these mistakes being often considered clinically unacceptable. Therefore, researchers need to consider the resilience of the rat model when designing and analyzing future studies. In addition, microsurgery instructors should focus on individual stitch quality rather than the final patency.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Orthopedic Surgery, Columbia University Irving Medical Center, New York, New York.
- Harley Street Clinic, London, UK.
ORCID-Profile: John J Corvi
Förderung
- Orthopedic Scientific Research Foundation
Zitieren
APA
Paladino, J. R., Zheng, Y., Gasteratos, K., Corvi, J. J., Park, K. H., & Akelina, Y. (2024). Rat Microvascular Model is Tolerant to Technical Errors. Journal of Reconstructive Microsurgery, 40(04), 245-252. https://doi.org/10.1055/a-2153-2467
Vancouver
Paladino JR, Zheng Y, Gasteratos K, Corvi JJ, Park KH, Akelina Y. Rat Microvascular Model is Tolerant to Technical Errors. Journal of Reconstructive Microsurgery. 2024;40(04):245-252. doi:10.1055/a-2153-2467
BibTeX
@article{Paladino2024,
author = {Paladino, Joseph R and Zheng, YuanDian and Gasteratos, Konstantinos and Corvi, John J and Park, Katherine H and Akelina, Yelena},
title = {Rat Microvascular Model is Tolerant to Technical Errors},
journal = {Journal of Reconstructive Microsurgery},
year = {2024},
volume = {40},
number = {04},
pages = {245--252},
doi = {10.1055/a-2153-2467}
}
EUVIMED