Evaluation of a novel anastomotic device in the animal model: A feasibility, safety, and efficacy study
Journal of Plastic, Reconstructive & Aesthetic Surgery · 2023
DOI: 10.1016/j.bjps.2023.07.025 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Plastic, Reconstructive & Aesthetic Surgery, 2023. Verfasst von Doron Klein und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Plastic and Reconstructive Surgery, Shamir Medical Center, Zerifin 70300, Israel. Electronic address: drkleinplastic@gmail.com. Hauptthemen laut MEDLINE: Arteries, Thrombosis. Die Arbeit nennt 17 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: A novel device was designed to assist with microvascular arterial anastomoses. This study compares the safety and efficacy of the anastomosis-assisting device with manual suturing in an ovine model. METHODS: Arteries with a diameter ranging from 2 to 4 mm were transected and anastomosed at four locations. A comparison was done between manual anastomoses and anastomoses performed with a novel anastomotic device in seven sheep. All the device-assisted anastomoses were performed by a single surgeon. At day 45 ± 7, anastomotic sites were dissected to determine patency, and samples were obtained for pathology. RESULTS: Thirteen of 13 (100%) samples from the Vesseal™ group demonstrated patency both on the day the anastomoses were performed and after the 45-day follow-up period. All four additional anastomoses performed using the Vesseal™ were found patent. In the hand-suturing group, six of six (100%) samples demonstrated patency on the day of the anastomoses and five of six (83%) were patent after the follow-up period. No thromboses or adverse events were observed in the anastomoses in either group. No difference in histopathology of the anastomoses was observed between the groups. CONCLUSIONS: The anastomosis-assisting device is a safe and efficacious alternative to hand suturing. The patency rates of device-assisted anastomoses were greater than those of manual suturing and pose no additional risk, as demonstrated by clinical observation, histopathology, and macroscopic evaluation. The Vesseal™ anastomosis-assisting device may be a viable alternative to manual suturing, with an ergonomic and intuitive design, short learning curve, and consistent results.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Plastic and Reconstructive Surgery, Shamir Medical Center, Zerifin 70300, Israel. Electronic address: drkleinplastic@gmail.com.
- Department of Plastic and Reconstructive Surgery, Shamir Medical Center, Zerifin 70300, Israel.
- Department of Plastic and Reconstructive Surgery, Rambam Health Care Campus, Haifa, Israel.
Zitieren
APA
Klein, D., Heller, L., Sorkin, A., & Zeltzer, A. A. (2023). Evaluation of a novel anastomotic device in the animal model: A feasibility, safety, and efficacy study. Journal of Plastic, Reconstructive & Aesthetic Surgery. https://doi.org/10.1016/j.bjps.2023.07.025
Vancouver
Klein D, Heller L, Sorkin A, Zeltzer AA. Evaluation of a novel anastomotic device in the animal model: A feasibility, safety, and efficacy study. Journal of Plastic, Reconstructive & Aesthetic Surgery. 2023. doi:10.1016/j.bjps.2023.07.025
BibTeX
@article{Klein2023,
author = {Klein, Doron and Heller, Lior and Sorkin, Alex and Zeltzer, Assaf A},
title = {Evaluation of a novel anastomotic device in the animal model: A feasibility, safety, and efficacy study},
journal = {Journal of Plastic, Reconstructive & Aesthetic Surgery},
year = {2023},
doi = {10.1016/j.bjps.2023.07.025}
}
EUVIMED