EUVIMEDEUVIMED entdecken
Crossref

Phantom and in vivo accuracy of frameless optical navigation in stereotactic laser interstitial thermal therapy

Ilaria Viozzi, Maxime J P Schoonbrood, Vincent J Ribbens, Mark Ter Laan, Christiaan G Overduin

Journal of Neurosurgery · 2024

DOI: 10.3171/2024.3.jns24193 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Neurosurgery, 2024. Verfasst von Ilaria Viozzi und 4 weiteren Autor:innen. Beteiligte Einrichtung: Departments of1Neurosurgery and. Hauptthemen laut MEDLINE: Phantoms, Imaging, Laser Therapy, Brain Neoplasms, Stereotaxic Techniques. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 18 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE Targeting accuracy presents a key factor in achieving maximal safe ablation in laser interstitial thermal therapy (LITT). The VarioGuide system has proven precise for brain biopsies, but data showing its accuracy in combination with LITT are limited. The aim of this study was to determine the phantom and in vivo accuracy of LITT probe placement using the VarioGuide system and to evaluate the effect of targeting error on maximum possible ablation volume. METHODS Stereotactic LITT probe placement was performed using the VarioGuide system in 3 phantom skulls. The same system was used in 10 patients treated with LITT, for which data were retrospectively analyzed. Target point error (TPE), target depth deviation (TDD), target lateral deviation (TLD), and angular deviation (AD) were derived from intraprocedural MRI scans of both the phantom and in vivo trajectories. In vivo, the effect of targeting error on the maximum reachable ablation was calculated as the difference between the planned maximal achievable tumor ablation (PTA) and the actual maximal achievable tumor ablation (ATA). RESULTS In total, 24 phantom and 16 in vivo trajectories were analyzed. In the phantom setting, the median TPE was 3.3 mm and median AD was 1.9°. Targeting accuracy significantly decreased for longer trajectories and those less perpendicular to the skull. In patients, the authors observed a comparable median TPE of 4.0 mm but significantly higher AD of 3.2°. In vivo, targeting inaccuracy resulted in a median decrease in maximum achievable ablation volume of 6% as compared to the planned trajectory. CONCLUSIONS The authors’ study indicates that utilizing the VarioGuide system in combination with LITT yields an average targeting error as large as 4 mm, which was smaller for shorter and straighter trajectories. In patients, targeting inaccuracy resulted in a median 6% decrease of the planned tumor ablation volume. These are important factors that should be considered in optimal case planning and patient selection in LITT.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Phantoms, ImagingLaser TherapyBrain NeoplasmsStereotaxic TechniquesNeuronavigationHumansRetrospective StudiesMagnetic Resonance ImagingFemaleMiddle AgedMaleAgedAdult

Stichwörter der Autor:innen

VarioGuideaccuracyframeless stereotaxislaser interstitial thermal therapysurgical technique

Autor:innen und Institutionen

  • Departments of1Neurosurgery and.
  • 2Technical Medicine, University of Twente, Enschede, The Netherlands.
  • 3Radiology, Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen; and.

Zitieren

APA

Viozzi, I., Schoonbrood, M. J. P., Ribbens, V. J., Laan, M. T., & Overduin, C. G. (2024). Phantom and in vivo accuracy of frameless optical navigation in stereotactic laser interstitial thermal therapy. Journal of Neurosurgery. https://doi.org/10.3171/2024.3.jns24193

Vancouver

Viozzi I, Schoonbrood MJP, Ribbens VJ, Laan MT, Overduin CG. Phantom and in vivo accuracy of frameless optical navigation in stereotactic laser interstitial thermal therapy. Journal of Neurosurgery. 2024. doi:10.3171/2024.3.jns24193

BibTeX
@article{Viozzi2024,
  author = {Viozzi, Ilaria and Schoonbrood, Maxime J P and Ribbens, Vincent J and Laan, Mark Ter and Overduin, Christiaan G},
  title = {Phantom and in vivo accuracy of frameless optical navigation in stereotactic laser interstitial thermal therapy},
  journal = {Journal of Neurosurgery},
  year = {2024},
  doi = {10.3171/2024.3.jns24193}
}
Kostenlos starten →