EUVIMEDEUVIMED entdecken
Crossref

Respiration-Related Catheter Displacement and Physiological Tolerance of High-Frequency Very Low Tidal Volume Ventilation With Peak Pressure Limitation During Atrial Fibrillation Ablation: A Prospective 1-Way Crossover Pilot Study

Carlos Rafael Ramírez-Paesano, Yerlin-Andrés Colina-Vargas, Lucio Teresi, Diego Penela, Giulio Falasconi, Francesco Amata, Daniel Tresandi, Angelica Cersosimo, Josep Rodiera Olive, David Soto-Iglesias, Julio Marti-Almor, Antonio Berruezo

Journal of Cardiothoracic and Vascular Anesthesia · 2026

DOI: 10.1053/j.jvca.2026.06.032 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Cardiothoracic and Vascular Anesthesia, 2026. Verfasst von Carlos Rafael Ramírez-Paesano und 11 weiteren Autor:innen. Beteiligte Einrichtung: Centro Médico Teknon, Quironsalud, Servei Central d'Anestesiología (Anestalia), Barcelona, Spain. Electronic address: cramirez@anestalia.com. Hauptthemen laut MEDLINE: Atrial Fibrillation, Catheter Ablation, Tidal Volume, High-Frequency Ventilation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 41 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: To evaluate whether high-frequency, very low tidal volume ventilation with controlled peak inspiratory pressure limitation (HFvLTV-cPP) is associated with reduced respiration-related catheter displacement during atrial fibrillation (AF) ablation, while maintaining short-term physiological tolerance. DESIGN: Prospective, single-center, fixed-sequence within-patient crossover pilot study. SETTING: Tertiary electrophysiology center. PARTICIPANTS: Fifty-two consecutive eligible adult patients undergoing radiofrequency catheter ablation for AF under general anesthesia. INTERVENTION: Standard ventilation followed by HFvLTV-cPP (50 breaths·min⁻¹, inspiratory-to-expiratory ratio 1:1, tidal volume titrated to minimize catheter displacement, peak inspiratory pressure ≤20 cmH2O), delivered using a standard anesthesia workstation. MEASUREMENTS AND MAIN RESULTS: HFvLTV-cPP was associated with a marked reduction in catheter displacement (6.22 ± 2.18 mm v 1.23 ± 0.69 mm; -4.99 mm, p 60 mmHg in 9.6% of patients. Oxygenation remained preserved. Plateau pressures were not increased, and driving pressure was lower. Mean arterial pressure decreased after induction but not after HFvLTV-cPP, with modest vasopressor use. No procedural complications occurred. Early recovery was rapid, without early respiratory or neurologic complications. CONCLUSIONS: HFvLTV-cPP was associated with marked motion reduction and short-term physiological tolerance in a selected cohort. These findings represent a mechanistic signal and do not establish clinical benefit or safety. Randomized studies are required.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationCatheter AblationTidal VolumeHigh-Frequency VentilationHumansCross-Over StudiesPilot ProjectsProspective StudiesMaleFemaleMiddle AgedAged

Stichwörter der Autor:innen

anesthesiaatrial fibrillationcatheter ablationcatheter stabilityhigh-frequency, very low tidal ventilationhypercapniamechanical ventilationpeak pressure limitation

Autor:innen und Institutionen

  • Centro Médico Teknon, Quironsalud, Servei Central d'Anestesiología (Anestalia), Barcelona, Spain. Electronic address: cramirez@anestalia.com.
  • Centro Médico Teknon, Quironsalud, Servei Central d'Anestesiología (Anestalia), Barcelona, Spain.
  • ICOR, Centro Médico Teknon, Quironsalud, Barcelona, Spain.
  • Department of Biomedical Sciences, Humanitas University, Milan, Italy.

Zitieren

APA

Ramírez-Paesano, C. R., Colina-Vargas, Y. A., Teresi, L., Penela, D., Falasconi, G., Amata, F., Tresandi, D., Cersosimo, A., Olive, J. R., Soto-Iglesias, D., Marti-Almor, J., & Berruezo, A. (2026). Respiration-Related Catheter Displacement and Physiological Tolerance of High-Frequency Very Low Tidal Volume Ventilation With Peak Pressure Limitation During Atrial Fibrillation Ablation: A Prospective 1-Way Crossover Pilot Study. Journal of Cardiothoracic and Vascular Anesthesia. https://doi.org/10.1053/j.jvca.2026.06.032

Vancouver

Ramírez-Paesano CR, Colina-Vargas YA, Teresi L, Penela D, Falasconi G, Amata F, et al. Respiration-Related Catheter Displacement and Physiological Tolerance of High-Frequency Very Low Tidal Volume Ventilation With Peak Pressure Limitation During Atrial Fibrillation Ablation: A Prospective 1-Way Crossover Pilot Study. Journal of Cardiothoracic and Vascular Anesthesia. 2026. doi:10.1053/j.jvca.2026.06.032

BibTeX
@article{RamrezPaesano2026,
  author = {Ramírez-Paesano, Carlos Rafael and Colina-Vargas, Yerlin-Andrés and Teresi, Lucio and Penela, Diego and Falasconi, Giulio and Amata, Francesco and Tresandi, Daniel and Cersosimo, Angelica and Olive, Josep Rodiera and Soto-Iglesias, David and Marti-Almor, Julio and Berruezo, Antonio},
  title = {Respiration-Related Catheter Displacement and Physiological Tolerance of High-Frequency Very Low Tidal Volume Ventilation With Peak Pressure Limitation During Atrial Fibrillation Ablation: A Prospective 1-Way Crossover Pilot Study},
  journal = {Journal of Cardiothoracic and Vascular Anesthesia},
  year = {2026},
  doi = {10.1053/j.jvca.2026.06.032}
}
Kostenlos starten →