Association of atrial mechanical dispersion with atrial fibrillation recurrence following catheter ablation: results of the ASTRA-AF pilot study

Dorit Knappe, Julia Vogler, Jessica Weimann, Victor Banas, Sevenai Yildirim, Felix Memenga, Juliana Senftinger, Laura Keil, Djemail Ismaili, Moritz Nies, Andreas Rillig, Stephan Willems und 4 weitere

Clinical Research in Cardiology · 2025-01 · 114 (1) · 103-111

DOI: 10.1007/s00392-024-02435-0 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Research in Cardiology, online erschienen am 21.05.2024. Verfasst von Dorit Knappe und 15 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, University Heart and Vascular Center Hamburg, Martinistraße 52, 20251, Hamburg, Germany. d.knappe@uke.de. Hauptthemen laut MEDLINE: Atrial Fibrillation, Catheter Ablation, Heart Atria, Pulmonary Veins. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitätsklinikum Hamburg-Eppendorf (UKE).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

For patients with symptomatic drug-refractory atrial fibrillation (AF), catheter ablation to achieve rhythm control is an important therapeutic option. The atrial mechanical dispersion measured as standard deviation of the time to peak strain (SD-TPS) is associated with the risk of AF recurrence following catheter ablation.

Methods

The study cohort prospectively enrolled n = 132 consecutive patients with paroxysmal ( n = 88) or persistent AF ( n = 44) presenting for de novo pulmonary vein isolation (PVI) and followed for 1 year. We related left atrial (LA) volume, LA ejection fraction, SD-TPS, and global longitudinal strain of the left ventricle and clinical variables (sex, age, and type of AF) to AF recurrence.

Results

Kaplan–Meier curves showed higher AF recurrence rate with an increase of SD-TPS with the calculated cut-off of 38.6 ms. Uni- and multivariable Cox regression analysis could show that SD-TPS had the highest relevance regarding AF recurrence with a HR of 1.05 (95% CI, 1.01; 1.09, p = 0.01) and HR of 1.05 (95% CI, 1.01; 1.09, p = 0.02) per 10 ms increase. In the additional analyses for the model including the clinical variables age, sex, and type of AF with paroxysmal or persisting AF, SD-TPS did only show a trend and after adjusting for covariates, SD-TPS showed a HR of 1.04 (95% CI, 0.99; 1.09, p = 0.09) per 10 ms increase.

Conclusion

Atrial mechanical dispersion was associated with recurrent AF. Graphical Abstract

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationCatheter AblationHeart AtriaPulmonary VeinsAtrial Function, LeftHeart RateHumansMaleFemaleRecurrenceMiddle AgedPilot ProjectsProspective StudiesAgedRisk FactorsFollow-Up StudiesTreatment OutcomeTime FactorsStroke Volume

Stichwörter der Autor:innen

Atrial fibrillationAtrial mechanical dispersionCatheter ablationEchocardiographyRecurrence of atrial fibrillation

Autor:innen und Institutionen

  • Department of Cardiology, University Heart and Vascular Center Hamburg, Martinistraße 52, 20251, Hamburg, Germany. d.knappe@uke.de.
  • Department of Rhythmology, University Heart Center Lübeck, Lübeck, Germany.
  • Department of Cardiology, University Heart and Vascular Center Hamburg, Martinistraße 52, 20251, Hamburg, Germany.
  • Department of Medicine III (Cardiology, Angiology, Intensive Care Medicine), University Hospital Schleswig-Holstein, Kiel, Germany.
  • Department of Cardiology and Internal Intensive Care Medicine, Asklepios Hospital St. Georg, Hamburg, Germany.
  • German Center for Cardiovascular Research (DZHK), Partner Site Hamburg/Kiel/Lübeck, Hamburg, Germany.

Förderung

  • Universitätsklinikum Hamburg-Eppendorf (UKE)

Zitieren

APA

Knappe, D., Vogler, J., Weimann, J., Banas, V., Yildirim, S., Memenga, F., Senftinger, J., Keil, L., Ismaili, D., Nies, M., Rillig, A., Willems, S., Blankenberg, S., Kirchhof, P., Metzner, A., & Sinning, C. (2025). Association of atrial mechanical dispersion with atrial fibrillation recurrence following catheter ablation: results of the ASTRA-AF pilot study. Clinical Research in Cardiology, 114(1), 103-111. https://doi.org/10.1007/s00392-024-02435-0

Vancouver

Knappe D, Vogler J, Weimann J, Banas V, Yildirim S, Memenga F, et al. Association of atrial mechanical dispersion with atrial fibrillation recurrence following catheter ablation: results of the ASTRA-AF pilot study. Clinical Research in Cardiology. 2025;114(1):103-111. doi:10.1007/s00392-024-02435-0

BibTeX
@article{Knappe2025,
  author = {Knappe, Dorit and Vogler, Julia and Weimann, Jessica and Banas, Victor and Yildirim, Sevenai and Memenga, Felix and Senftinger, Juliana and Keil, Laura and Ismaili, Djemail and Nies, Moritz and Rillig, Andreas and Willems, Stephan and Blankenberg, Stefan and Kirchhof, Paulus and Metzner, Andreas and Sinning, Christoph},
  title = {Association of atrial mechanical dispersion with atrial fibrillation recurrence following catheter ablation: results of the ASTRA-AF pilot study},
  journal = {Clinical Research in Cardiology},
  year = {2025},
  volume = {114},
  number = {1},
  pages = {103--111},
  doi = {10.1007/s00392-024-02435-0}
}