EUVIMEDEUVIMED entdecken
Vergleichsstudie

Comparison of Preoperative and Intraoperative Assessment of Tricuspid Valve Annular Diameter and Tricuspid Regurgitation Grade by Echocardiography in Patients Undergoing Mitral Valve Surgery

Maxim Glebov, Haim Berkenstadt, Dina Orkin, Mais Otmani, Niv Levin, Maksim Katsin, Yonatan Gargi, Alexander Kogan, Jonathan Frogel

Journal of Cardiothoracic and Vascular Anesthesia · 2026

DOI: 10.1053/j.jvca.2026.06.002 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Cardiothoracic and Vascular Anesthesia, 2026. Verfasst von Maxim Glebov und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, Sheba Medical Center, Ramat Gan, Israel; Department of Information Systems, University of Haifa, Haifa, Israel. Hauptthemen laut MEDLINE: Tricuspid Valve Insufficiency, Tricuspid Valve, Echocardiography, Transesophageal, Preoperative Care. Die Arbeit nennt 13 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: To compare preoperative transthoracic echocardiography (TTE) and intraoperative transesophageal echocardiography (TEE) assessment of (1) tricuspid annular diameter (TAd) and (2) tricuspid regurgitation (TR) grade in adults undergoing mitral valve surgery, with or without concomitant tricuspid surgery. DESIGN: Retrospective cohort study. SETTING: Single tertiary academic medical center. PARTICIPANTS: Seventy-seven consecutive adults presenting for mitral valve surgery with an available preoperative TTE performed ≤1 week before surgery. INTERVENTIONS: None. MEASUREMENTS: Multiple TAd measurements were made with the maximum diastolic TAd recorded per modality (TTE: apical 4-chamber; TEE: mid-esophageal 4-chamber). TR severity was graded per society guidelines. Paired comparisons, correlation, and Bland-Altman analyses were performed. RESULTS: Mean preoperative TTE TAd was 38.0 ± 4.9 mm (TTE) versus mean intraoperative TEE TAd of 37.2 ± 5.4 mm (TEE), with a mean paired difference of +0.83 ± 5.04 mm (95% CI, -0.31 to 1.98; p = 0.152). TEE TAd measurement was decreased compared with TTE in 44 of 77 (57.1%) patients, increased in 27 of 77 (35.1%), and was unchanged in 6 of 77 (7.8%) (p = 0.009 for decreased > increased). TR grade distributions also differed between modalities (p = 0.008), with TEE TR severity increased compared with TTE in 22 of 77 (28.6%), decreased in 15 of 77 (19.5%), and unchanged in 40 of 77 (51.9%). TAd correlation was moderate (Pearson r = 0.526; Spearman ρ = 0.521). Bland-Altman analysis demonstrated a small bias (+0.83 mm) but wide limits of agreement (-9.05 to +10.71 mm), indicating substantial case-level variability. CONCLUSIONS: Although TTE and TEE yield similar mean TAd, per-patient agreement is only moderate. In addition, TR grade is frequently reclassified under anesthesia. Reliance on intraoperative TEE for either TAd or TR severity assessment may lead to misclassification, particularly in borderline cases. Relying chiefly on TTE assessment, considering hemodynamic context, and incorporating TEE 3-dimensional annular metrics when available may improve decision-making regarding concomitant tricuspid repair during mitral surgery.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tricuspid Valve InsufficiencyTricuspid ValveEchocardiography, TransesophagealPreoperative CareMitral ValveEchocardiographyMonitoring, IntraoperativeHumansRetrospective StudiesFemaleMaleMiddle AgedAgedCohort Studies

Stichwörter der Autor:innen

echocardiographymitral valve surgerytricuspid regurgitationtricuspid valve repair

Autor:innen und Institutionen

  • Department of Anesthesiology, Sheba Medical Center, Ramat Gan, Israel; Department of Information Systems, University of Haifa, Haifa, Israel.
  • Department of Anesthesiology, Sheba Medical Center, Ramat Gan, Israel; Faculty of Medicine, Tel-Aviv University, Israel.
  • Department of Anesthesiology, Sheba Medical Center, Ramat Gan, Israel.
  • Department of Anesthesiology, Sheba Medical Center, Ramat Gan, Israel. Electronic address: jonathan.frogel@sheba.health.gov.il.

Zitieren

APA

Glebov, M., Berkenstadt, H., Orkin, D., Otmani, M., Levin, N., Katsin, M., Gargi, Y., Kogan, A., & Frogel, J. (2026). Comparison of Preoperative and Intraoperative Assessment of Tricuspid Valve Annular Diameter and Tricuspid Regurgitation Grade by Echocardiography in Patients Undergoing Mitral Valve Surgery. Journal of Cardiothoracic and Vascular Anesthesia. https://doi.org/10.1053/j.jvca.2026.06.002

Vancouver

Glebov M, Berkenstadt H, Orkin D, Otmani M, Levin N, Katsin M, et al. Comparison of Preoperative and Intraoperative Assessment of Tricuspid Valve Annular Diameter and Tricuspid Regurgitation Grade by Echocardiography in Patients Undergoing Mitral Valve Surgery. Journal of Cardiothoracic and Vascular Anesthesia. 2026. doi:10.1053/j.jvca.2026.06.002

BibTeX
@article{Glebov2026,
  author = {Glebov, Maxim and Berkenstadt, Haim and Orkin, Dina and Otmani, Mais and Levin, Niv and Katsin, Maksim and Gargi, Yonatan and Kogan, Alexander and Frogel, Jonathan},
  title = {Comparison of Preoperative and Intraoperative Assessment of Tricuspid Valve Annular Diameter and Tricuspid Regurgitation Grade by Echocardiography in Patients Undergoing Mitral Valve Surgery},
  journal = {Journal of Cardiothoracic and Vascular Anesthesia},
  year = {2026},
  doi = {10.1053/j.jvca.2026.06.002}
}
Kostenlos starten →