Combined mitral and tricuspid TEER with a single TriClip steerable guide catheter: A single-center study
Cardiovascular Revascularization Medicine · 2025
DOI: 10.1016/j.carrev.2025.04.033 ↗Kurz gefasst
Fachartikel in der Zeitschrift Cardiovascular Revascularization Medicine, 2025. Verfasst von Georgios E Papadopoulos und 4 weiteren Autor:innen. Beteiligte Einrichtung: 2nd Cardiology Department, Interbalkan Medical Center, Thessaloniki, Greece. Hauptthemen laut MEDLINE: Tricuspid Valve Insufficiency, Mitral Valve Insufficiency, Tricuspid Valve, Cardiac Catheterization. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 12 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Combined M- and T- TEER typically involves two separate systems, complicating logistics and increasing procedural risks. This study aims to evaluate the safety and efficacy of combined mitral (M-TEER) and tricuspid (T-TEER) transcatheter edge-to-edge repair using a single TriClip® steerable guide catheter (SGC). METHODS: Patients with moderate-to-severe (3+) or severe (4+) degenerative (DMR) or functional (FMR) mitral regurgitation and massive/torrential or severe functional tricuspid regurgitation (TR), classified as New York Heart Association (NYHA) class III or IV, who underwent combined M- and T- TEER with the same TriClip SGC between January 2022 and December 2024, were included. The primary objectives included procedural outcomes, MR and TR severity reduction, and NYHA class improvement. RESULTS: Among 42 patients (64 % female; median age: 77 years [IQR: 9]), the implantation success rate was 100 %, with mean device and procedure times of 39.2 ± 6.9 and 71.2 ± 9.6 min, respectively. There were no in-hospital or 30-day major adverse events (MAEs), except for 2 patients (4.8 %) with tricuspid single leaflet device attachment (SLDA), and 1 patient (2.4 %) who underwent atrial septal defect (ASD) closure. Over a median follow-up period of 0.91 years, 3 (7.1 %) patients were hospitalized for heart failure, with zero mortality. At 1-year follow-up, all patients achieved NYHA class ≤II, along with MR ≤2+ and 34 (81 %) patients had only trivial/mild TR. CONCLUSIONS: Combined M-TEER and T-TEER using the same TriClip SGC demonstrated favorable safety and efficacy, along with significant functional and echocardiographic improvements.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- 2nd Cardiology Department, Interbalkan Medical Center, Thessaloniki, Greece.
- 2nd Cardiology Department, Interbalkan Medical Center, Thessaloniki, Greece. Electronic address: vninios@gmail.com.
Zitieren
APA
Papadopoulos, G. E., Ninios, I., Evangelou, S., Ioannides, A., & Ninios, V. (2025). Combined mitral and tricuspid TEER with a single TriClip steerable guide catheter: A single-center study. Cardiovascular Revascularization Medicine. https://doi.org/10.1016/j.carrev.2025.04.033
Vancouver
Papadopoulos GE, Ninios I, Evangelou S, Ioannides A, Ninios V. Combined mitral and tricuspid TEER with a single TriClip steerable guide catheter: A single-center study. Cardiovascular Revascularization Medicine. 2025. doi:10.1016/j.carrev.2025.04.033
BibTeX
@article{Papadopoulos2025,
author = {Papadopoulos, Georgios E and Ninios, Ilias and Evangelou, Sotirios and Ioannides, Andreas and Ninios, Vlasis},
title = {Combined mitral and tricuspid TEER with a single TriClip steerable guide catheter: A single-center study},
journal = {Cardiovascular Revascularization Medicine},
year = {2025},
doi = {10.1016/j.carrev.2025.04.033}
}
EUVIMED